Inductively Coupled Plasma - Optical Emission Spectrometry
Closed Solicitation Posted
- Solicitation number
- W911S227U0002
- Agency
-
MICC Fort Drum
Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- PSC
- 6630 Chemical Analysis Instruments
- Place of performance
- 2744 Rodman Ave. Rock Island, Illinois 61299
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum seeks an Inductively Coupled Plasma - Optical Emission Spectrometry instrument, with proposals due October 9. The procurement is a Total Small Business set-aside.
Place of performance is Rock Island, Illinois (2744 Rodman Ave). The mandatory technical requirements specify a bench-top ICP-OES system with simultaneous UV and visible determinations, comparable to an Agilent 5800 or equivalent meeting detailed specifications. The spectrometer must feature an Echelle polychromator with 253 mm focal length, single solid-state detector with pixel-level anti-blooming capability, and resolution less than 0.0065 nm at 200 nm and less than 0.013 nm at 327.4 nm. The optical enclosure must be purged and thermostated, with purge rate of 0.7 L/min and 3 L/min boost capability for wavelengths below 189 nm. The system must view at least 96% of the emission spectrum from 167–785 nm and accommodate both aqueous and organic matrices including oil, MIBK, kerosene, and hexanes. The ICP system requires dual-view vertical plasma with synchronous axial and radial capability, bench-top design, and operation at 15–30 degrees Celsius and 25–80% relative humidity with no performance loss at rates up to 2 degrees C per hour. Exhaust capacity must meet or exceed 2.5 cubic meters per minute, and power consumption must not exceed 2.9 kVA at 200–240 VAC, 50–60 Hz, with current draw at or below 15 amps. The RF generator must be solid-state, 750–1500 watts in 10-watt increments, with at least 75% power transfer efficiency and typical stability of 0.1%. The detector must be Peltier-cooled to at least −40 degrees Celsius with Adaptive Integration capability and hermetic sealing requiring no gas purge. All plasma gases must use mass flow controllers with integrated, computer-controlled oxygen addition for organics. The NAICS code is 334516, Analytical Laboratory Instrument Manufacturing; PSC is 6630.
Notice text
MANDATORY MINIMUM REQUIREMENTS: Preferred instrument: ICP- OES comparable to the Agilent 5800; vendors may offer any equivalent system that meets the required specifications.1. Spectrometer RequirementsSimultaneous reading ICP OES w/ solid state detector.Bench top design only. Floor mount not acceptable.Echelle polychromator, 253 mm focal length, single detector, single entrance slit. Resolution: less than 0.0065 nm @ 200 nm; less than 0.013 nm @ 327.4 nm.Purged + thermostated optical enclosure; purge 0.7 L/min w/ 3 L/min boost option (less than 189 nm).Pixel level anti blooming detector.Vertical plasma; single piece torch. Optional torches must be available.View equal to or greater than 96% emission spectrum from 167-785 nm.Simultaneous UV + Vis determinations in one measurement.2. ICP System RequirementsBench top system; dual view vertical plasma (synchronous axial/radial).Must run aqueous + organic matrices including oil, MIBK, kerosene, hexanes.Monitors gas pressures/flows, water flows, air pressure, exhaust, plasma stability; auto shutdown on interlock breach.Operates at 15-30 degrees C and 25-80% RH; tolerates 2 degrees C/hr change with no performance loss.Exhaust requirement: equal to or greater than 2.5 m^3/min (88 ft^3/min).Power: equal to or less than 2.9 kVA, 200-240 VAC, 50-60 Hz, equal to or less than 15 amps3. Detector RequirementsSingle solid state detector; simultaneous reading of all wavelengths.Peltier cooled to equal to or less than -40 degrees C; Adaptive Integration capability.Hermetically sealed; no gas purge required.4. RF Generator RequirementsSolid state generator, 750-1500 W, 10 W increments.equal to or greater than 75% power transfer efficiency; typical stability 0.1%.5. Gas Flow ControlsAll plasma gases (coolant, auxiliary, nebulizer, makeup) must use mass flow controllers.Must meet flow ranges + increments listed in Government technical criteria.Integrated, computer controlled oxygen addition for organics.6. Sample Introduction SystemCassette style vertical torch; no manual adjustments required after mounting.Double pass glass cyclonic spray chamber + glass concentric nebulizer.Five channel variable speed peristaltic pump; up to 80 rpm.7. Software Requirements64 bit software; Windows 11 compatible.Automated background + spectral interference correction; automatic IEC recalculation.QC system supporting blanks, spikes, duplicates, and corrective actions.Full raw data saving + complete post run reprocessing.8. Performance RequirementsMust meet all EPA ICP OES detection limits and CRDLs using concentric nebulizer + cyclonic spray chamber.9. Additional RequirementsNew instrument; refurbished/demo units not acceptable.One year warranty (parts, labor, travel).Separate, remotely placeable water chiller.Autosampler holding equal to or greater than 180 sample positions + equal to or greater than 11 standards10. Hydrofluoric Acid Compatibility RequirementSample introduction systems must be or include compatible hardware for hydrofluoric acid use. This shall include, at a minimum, an HF-resistant nebulizer and spray chamber11. Certified Metal Standards Accuracy RequirementThe instrument shall be capable of analyzing within +/- 10% of certified values of metal standards (either chip or atomized metal powder) for typical alloy steel grades, typical stainless steel grades, typical copper alloys, typical cast and wrought aluminum, and titanium alloys with proper preparation for metallurgical elements excluding elements atypical of interrogation by ICP-OES methods such as carbon, nitrogen, hydrogen, and oxygen.
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| ICP-OES for Oil Analysis | MICC Fort Drum | Total Small Business | |
| Sources Sought for (ICP-OES) Spectrometer System with an Autosampler | Naval Supply Systems Command | No set-aside | |
| Nitrogen Content Analysis Equipment | MICC Fort Drum | Total Small Business | |
| Scintillometer BLS900 Neo, Path Reduction Aperture, Power Supply, Standard and Tall Tripods | MICC Fort Drum | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity