Patient Monitoring Equipment, Battle Creek
Award Notice Posted
- Solicitation number
- 36C25022Q1000
- Agency
-
Veterans Integrated Service Network 10
Veterans Health Administration, Department of Veterans Affairs
- Awarded
- to Four Points Technology, L.L.C.
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- Contract number
- 36C25022P2003-515A20060 Federal contract award
- NAICS code
- 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
- Place of performance
- Battle Creek, Michigan 49037, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This Award Notice from the Department of Veterans Affairs Veterans Health Administration announces the award of a firm-fixed price contract valued at $301,364.87 to Four Points Technology, L.L.C. to upgrade the existing Philips patient monitoring platform and IntelliBridge Enterprise solution at the Battle Creek VA Medical Center and Wyoming CBOC in Michigan. The upgrade must be completed by January 26, 2023 to ensure compatibility with the new Cerner EMR system implementation scheduled for June 2023.
Notice text
- Contract Title.
Battle Creek VA Medical Center/WCBOC: Patient Monitoring System replacement
- Background.
The Battle Creek VAMC/WCBOC currently utilizes an existing Spacelabs patient monitoring system (not CERNER complaint). The Battle Creek VAMC/WCBOC requires a system-wide standardization of software maintenance and CERNER compatibility. Installation for CERNER will be completed by 6-17-2023.
3. Scope.
The Battle Creek VAMC/WCBO is requesting a system-wide replacement to the
existing patient monitoring system. The upgrades will include upgrades to Clinical
Decision Support Tools, Cybersecurity, Monitoring Hardware, Software, IntelliBridge
Enterprise Solution (required for Cerner implementation). All network cabling and
mounting of equipment to be supplied by Philips.
4. Specific Tasks.
There are no equipment trade-ins or removals from either of the Battle Creek or
Wyoming CBOC facilities. Two servers will be located at the Battle Creek VAMC
facility, and all monitors and central station are to be located in the GI clinic at
WCBOC.
Vendor is to provide all tools, equipment, and transportation necessary to complete
installation.
●Enhance Clinical Decision Support Tools at the PIC iX/Central Station and bedside
monitoring. System shall provide Clinical Audit Logs and reports for alarms at the
PIC iX can assign sectors at bedside.
●Cybersecurity shall utilize the latest Microsoft OS that fully supports validated OS
security updates, patient data encryption, and malware protection with the capability
to expand and be capable to serve future surges in patient load.
●System must utilize a software optimizer.
●Must incorporate IntelliBridge Enterprise (IBE) Solution as an interface portal for
EMR to allow for bi-directional data flow to and from the Philips PIC iX Central
stations and bedside monitors. This system shall include integration to/from EMR for
document and wave strip data export, vital signs integration, patient ID matching for
admission, discharge, and transfer from unit to unit. Software maintenance
agreement must be included.
5. Performance Monitoring.
Performance monitoring will be complete by COR, Biomedical Engineering and
Nursing Operations.
6. Security Requirements.
The vendor/contractor will be upgrading the existing system utilizes electronic health
record information. The vendor /contractor will be supervised by VA staff while
completed the install to ensure that the vendor will not be accessing patient
information. Vendor/Contractor must abide by security requirements listed below from
VA Handbook 6500.6 Appendix B & C.
7. Government-Furnished Equipment (GFE)/Government-Furnished Information
(GFI).
No GFE or GFI will be furnished to the vendor for this request.
8. Other Pertinent Information or Special Considerations.
Due to the unique requirements necessary to accomplish this contract, specialized
experience with the Philips IntelliBridge patient monitoring system is required for this
request.
a. Identification of Possible Follow-on Work.
There is no anticipated follow-on work at this time for this request, but additional
follow-on work could include but is not limited to additional training and or
maintenance/support services.
b. Packaging, Packing and Shipping Instructions.
(server equipment)
Battle Creek VAMC Warehouse
5600 West Dickman Rd
Attn: Biomed
Battle Creek, MI 49037
and
(bedside monitors and central station)
WCBOC
5838 Metro Way
Attn: Biomed
Wyoming, MI 49519
c. Inspection and Acceptance Criteria.
Logistics and Biomedical Engineering staff will be responsible for all inspection and
acceptance criteria related to this request.
9. Risk Control.
There have been no patient or infection control issues brought to our attention for this
request. This request is for the upgrade and install of new equipment/software to our
existing patient monitoring systems.
10. Place of Performance.
Battle Creek VA Medical Center
5500 Armstrong Rd, bldg. 157
Battle Creek, MI 49037
and
Wyoming CBOC
GI Clinic
5838 Metro Way
Wyoming, MI 49519
11. Period of Performance.
The manufacturer’s warranty period. There are no option years associated with this contract. Delivery and implementation will be coordinated with vendor and VA stakeholder upon award.
12. Delivery Schedule.
01/26/2023.
Awarded contract 36C25022P2003 to FOUR POINTS TECHNOLOGY, L.L.C. for 301364.87 on 2022-09-26.
Files
| File | Type | Posted |
|---|---|---|
| Brand Name Justification-Sam Posting.rtf | RTF text file |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Award Notice | |
| Patient Monitoring Equipment, Battle Creek | Solicitation | |
| Patient Monitoring Equipment, Battle Creek | Pre-Solicitation |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity