NUWCDIVNPT-Construction-Vaporizer Enclosure (Design-Build)
Open Solicitation Posted
- Solicitation number
- N6660427Q0077
- Agency
-
Naval Sea Systems Command
Department of the Navy, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Newport, Rhode Island 02841, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Navy's Naval Sea Systems Command, through Naval Undersea Warfare Center Division Newport, seeks design-build construction services to enclose government vaporizer LP gas units under solicitation N66604-27-Q-0077, with quotations due December 17, 2026 at 2:00 PM EST. The procurement is a Total Small Business set-aside.
Place of performance is Newport, Rhode Island 02841. The award is firm-fixed-price across three CLINs: CLIN 0001 covers design services (concept, schematic, design-development, and final construction documents), CLIN 0002 covers the construction build per the approved final design, and CLIN 0003 covers construction submittals and is not separately priced. The design fee cannot exceed 6% of estimated construction cost per 10 U.S.C. 2306. Construction magnitude is estimated at $100,000 to $250,000, and the period of performance is 180 days after award. Performance and payment bonds are required within 10 days of award. The NAICS code is 236220 with a $45 million size standard, and the PSC is Y1AZ.
The solicitation incorporates DFARS 252.204-7019. The Contracting Officer cannot award to any bidder without an active NIST SP 800-171 assessment score posted in SPRS at the time of award evaluation. Offerors must maintain active SAM registration and CMMC Level 1 (Self) certification with a valid CMMC Unique Identifier. Controlled attachments require a SAM.gov access request that includes the company's active CAGE code and CMMC UID.
Key personnel requirements include a superintendent with 10+ years of experience, 5+ as superintendent; a Quality Control Manager with 5+ years; a Site Safety and Health Officer meeting EM 385-1-1 Level 1; and a Professional Engineer with 5+ years of design-build experience. The Environmental Management Plan must address soil contamination and Level D PPE. Past performance must show similar-scope projects completed within five years, preferably in hazardous industrial environments with contaminated soil mitigation under EM 385-1-1.
Award will be made on a best-value tradeoff basis, with technical capability and past performance significantly more important than price. The Government intends to evaluate quotations without discussions, so initial quotations must reflect best terms. Technical proposals are limited to 30 pages, and quotations are submitted in three volumes: Technical, Past Performance and Corporate Safety, and Cost/Price.
A site visit to Building 80 is scheduled for December 2, 2026 at 11:30 AM EST. Attendees must pre-register by email and obtain an approved Visit Authorization Request, which requires 7 business days for processing. Points of contact are Michael N. Ouellette (Michael.N.Ouellette.civ@us.navy.mil) for contractual, legal, and project-specific inquiries, and the SAM.gov Help Desk for access issues.
Notice text
INSTRUCTIONS TO REQUEST ACCESS TO RESTRICTED DOCUMENTS
Bidders must submit an access request through the SAM.gov "Controlled" document access system. To be approved for access, the Contractor must satisfy the following criteria:
STEP 1: SUBMIT THE ACCESS REQUEST IN SAM.GOV
In SAM.gov, locate the "Controlled" attachments under the "Attachments" section of this solicitation and click "Request Access."
STEP 2: PROVIDE CAGE CODE AND CMMC UNIQUE IDENTIFIER (UID)
In the "Reason for Access" text field, you MUST provide the following details:
- Active Company CAGE Code (Must be active in SAM.gov).
- Company CMMC Unique Identifier (UID) / SPRS Entry ID.
CYBERSECURITY MANDATE (DFARS 252.204-7019 / NIST SP 800-171)
Bidders are strictly cautioned that this project incorporates DFARS 252.204-7019 (Notice of NIST SP 800-171 DoD Assessment Requirements).
In accordance with DFARS 252.204-7019, the Contracting Officer is legally prohibited from awarding this contract to any bidder who does not have an active NIST SP 800-171 assessment score posted in SPRS at the time of award evaluation. Bidders are encouraged to ensure their SPRS postings are current (completed within the last 3 years) prior to proposal submission.
POINTS OF CONTACT (POC)
If you experience technical issues requesting access through SAM.gov, please contact the SAM.gov Help Desk. For contractual, legal, or project-specific inquiries, contact the following individuals immediately:
Michael Ouellette - Michael.N.Ouellette.civ@us.navy.mil
Files
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Construction-NUWCDIVNPT-Interior Renovations | Naval Sea Systems Command | Total Small Business | |
| Construction-NUWCDIVNPT HVAC Piping Insulation | Naval Sea Systems Command | Total Small Business | |
| P084 next generation torpedo integration lab, naval station newport, newport RI | Naval Facilities Engineering Command | No set-aside | |
| Machine Parts Small Shroud Testing Antennae | Naval Sea Systems Command | Total Small Business | |
| Closure Protective Covers (CPCs) | Naval Sea Systems Command | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities