Mobile Test Enclosure (MTE) Minimum Requirements

  • Dimensions: 20 feet long, 10 feet wide*, 8 feet 6 inches high
  • Qty (1) French-style double doors, each door with 28-inch clear opening, Qty (1) escape hatch with a 20-inch diameter opening, and Qty (1) 30-inch personnel door; doors and hatch are aluminum, insulated, and rated IP66 minimum
  • Painted in accordance with Structural Steel Painting Council (SSPC) Specifications; coatings are to be applied by a certified SSPC professional
  • All welding in accordance with American Welding Society Structural Welding Code D1.1 for any modifications that require welding;
  • Structural panel stiffening to ABS High Speed Craft guidelines
  • Prior to any modifications, the container shall be ISO/CSC certified and shall contain a CSC plate (International Convention for Safe Containers) dated within 5 years or have met a MIL-STD-3037 inspection and have a current DDFORM2282 decal; all certification documentation, plates, and decals shall be retained, in place, and intact; construction/modifications adheres to USCG Guide to Structural Fire Protection; IP66 complete MTE
  • 14 gauge minimum panel container thickness
  • Procure and install wire transits
  • Procure materials and install a rooftop support structure adequate to support an 850 kg equipment piece; see the current design is shown below.
  • Zone 1 Insulation with Ceiling: R30 minimum, Walls: R25 minimum, and Floor: R13 minimum R-Values
  • Procure and install five standard EIA-310-D compatible racks - 42u, 19 inch; 24-inches wide, 39-inches depth, 79-inches height
  • Procure and install a collapsible roof-top fall protection system
  • Wired to accept a 3-phase power supply which shall operate either from a 480 VAC, ungrounded neutral system or 208 VAC
  • Install a step-down/isolation transformer rated to isolate and convert the ship’s 480 VAC to the 208/115 VAC for the interior distribution.
  • Interior power distribution in the MTE shall be 208/115 VAC with the neutral grounded to the MTE structure
  • Procure and install interior lighting and Qty (20) 120V outlets of varying amperage
  • Procure and install heating, ventilation, and air conditioning (HVAC) unit with 24,000 BTU cooling capacity minimum
  • Non-Flammable insulation and sound absorption

Note:  These minimum requirements and drawings are for quote purposes only and are subject to change; they are not the final specifications of the Portable Test Enclosure (MTE).

* This width is not standard; modifications will be required and it is understood ISO/CSC certifications will be rendered invalid.

Attachments

Files attached to this notice, newest first
File Type Posted
drawings.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Mobile Test Enclosure (MTE) Award Award Notice
Mobile Test Enclosure (MTE) Latest solicitation Solicitation
Mobile Test Enclosure (MTE) This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity