About this opportunity

The Naval Supply Systems Command (NAVSUP) Fleet Logistics Center Norfolk is procuring one DBRS240420000 MaxGard Interlocked Receptacle with Circuit Breaker as a critical replacement for the TSV3 Hunter vessel. This shore-power cable receptacle/box replacement is necessary due to water intrusion that has created degraded electrical safety conditions, posing risks of shore electrical power loss and potential personnel electrocution. The specific equipment required is a 200 Amp, 3 Pole 4 Wire, 3 Phase 480V, 60Hz receptacle with a Breaker Trip Rating of 200 Amp, manufactured by Thomas & Betts (now ABB Installation Products Inc.). This procurement represents a brand-name sole source acquisition using simplified acquisition procedures under a firm-fixed-price contract structure. The solicitation was posted on August 28, 2025, with responses due by August 31, 2025, and delivery required by September 30, 2025.

This procurement does not utilize any set-aside designations and is open to all qualified vendors, though the brand-name specification effectively limits competition to authorized distributors of the Thomas & Betts/ABB product. No incumbent contractor information is provided, and the contract value remains to be determined (TBD) in the solicitation documents. The procurement involves a single unit replacement for immediate delivery to address critical electrical infrastructure needs aboard the naval vessel. Performance will occur at Fort Story, VA 23459, with specific delivery to TSV3 Hunter at 1320 Barnstable County Road, Building 3090, Virginia Beach, VA. Notably, contractor personnel will not require access to military bases or piers, as ship personnel will handle installation upon receipt of the equipment.

Notice text

The TSV3 Hunter requires a one-for-one replacement of DBRS240420000 MaxGard Interlocked Receptacle with Circuit Breaker (shore-power cable receptacle/box) due to water intrusion and correct degraded electrical safety onboard TSV3 Hunter.

The vendor selected shall provide One (1) DBRS240420000 MaxGard Interlocked Receptacle with Circuit Breaker: 200 Amp, 3 Pole 4 Wire, 3 Phase 480V, 60Hz, Breaker Trip Rating 200 Amp

Files

File Type Posted
Justification for Brand Name.docx DOCX document
Pre-Solicitation Synopsis.docx DOCX document
N0018925Q0506.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
Circuit breaker, in repair/modification of NAICS 335313 Naval Supply Systems Command No set-aside
N0038326PR0R803_FMS NAICS 335931 Naval Supply Systems Command No set-aside
CBL actr/lock PWR NAICS 335311 Naval Supply Systems Command No set-aside
CB safety DEV GEN 2 NAICS 335313 Naval Supply Systems Command No set-aside
CBL actr/lock PWR NAICS 335311 Naval Supply Systems Command No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors