Mammography reporting system - ST. Louis VAMC (JC)

Closed Pre-Solicitation Posted

Not the latest version. See the latest special notice from .

Solicitation number
36C25526Q0543
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
513210 Software Publishers
Place of performance
Saint Louis, Missouri 63106, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Integrated Service Network 15 is seeking sources for a mammography reporting system replacement at the St. Louis VAMC — John Cochran Division, with responses due by August 7, 2026. This is market research only and does not obligate the government to award a contract.

The facility is located at 915 North Grand Boulevard, St. Louis, Missouri 63106-1621. Vendors must submit company information, UEI number, GSA contract details if applicable, capability statement, product brochures with specifications, and an authorized distributor letter from the original equipment manufacturer.

The statement of work requires a complete mammography reporting system to replace the existing MRS7 system, including all equipment, accessories, installation services, and project management support. Key requirements include customizable patient tracking and reporting with risk calculation models (Tyrer-Cuzick v8), integration with RIS, PACS, workstation, and voice recognition workflows, HL7 interface capability, and compatibility with Cerner EHR with OEM attestation dated within 60 days of proposal submission. Software must be manufacturer-supported at delivery with unlimited perpetual licensing. Installation must occur within 30 days of delivery and include on-site clinical and maintenance training. Vendors must provide two copies each of operator's manuals, complete technical service manuals, and system manager's manuals. Warranty coverage must include all parts and labor for at least one year following acceptance, with 8-hour response times for technical calls and 48-hour parts replacement. Optional features include trade-in options, extended warranty plans, and comprehensive training packages with travel and lodging costs. Contact Tywanna Sparks, tywanna.sparks@va.gov or 913-758-9928. Responses are due August 7, 2026 at 11:00 AM Central Time.

Notice text

Mammography Reporting System, St. Louis VAMC - JC

See attached Sources Sought Notice for details.

Files

File Type Posted
Sources Sought Notice_36C25526Q0543.pdf PDF

Notice history

Notice Type Posted
Mammography reporting system - ST. Louis VAMC (JC) Latest special notice Special Notice
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
36C255-27-AP-0383 - IVX & Cerner to Interface with EHRM Columbia, Missouri 65201, United States · NAICS 541519 Veterans Integrated Service Network 15 No set-aside
Wound Vac Cleaning Maintenance Service | St. Louis VAMC Saint Louis, Missouri 63106, United States · NAICS 811210 Veterans Integrated Service Network 15 No set-aside
Nexodose dose monitor Kansas City, Missouri, United States · NAICS 541519 Veterans Integrated Service Network 15 No set-aside
Z2DA--657-26-102JC FCA Replace Various Roofs on BLDG 1, JC 915 N Grand Blvd. St. Louis, MO 63106 · NAICS 236220 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business
J065--Imaging Service & Preventative Maintenance EHCC & MTV Evansville Health Care Center Evanville, Indiana 47715, United States · NAICS 811210 Veterans Integrated Service Network 15 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity