Live fire training facility inspection

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
FA465924Q0001
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
541350 Building Inspection Services
Place of performance
Grand Forks AFB, North Dakota, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice seeks inspection services for the non-gas fired live fire training structure at Building 639, located at Grand Forks Air Force Base. The 319th Contracting Squadron is soliciting information from contractors capable of inspecting the facility in accordance with NFPA 1403 standards, including removing and reinstalling original thermal linings. Respondents must provide a five-year certificate of inspection and return all areas to their original condition. Capability statements not exceeding five pages must be submitted by March 13, 2024.

This requirement has a total small business set-aside designation, with an estimated NAICS code of 541990 for all other professional, scientific, and technical services. There is currently no incumbent, as this inspection is a new requirement. Responses will help determine the appropriate procurement method and ensure the structure can be properly evaluated according to safety standards over the next five years.

Notice text

2 versions

Update #2 · Latest ·

SOURCES SOUGHT

THIS IS NOT A SOLICITATION! This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.

The 319th Contracting Squadron, Grand Forks AFB, North Dakota, is issuing this Sources Sought as a means of conducting market research to identify parties having the resources to provide the following:

The Contractor shall provide all materials, plans, travel, labor, equipment, and supervisory staff necessary to be capable of inspecting the non-gas fired live fire training structure of Building 639, located at Grand Forks AFB. Said supervision shall be done in accordance with the requirements of NFPA 1403, 2018 Edition, Chapter 7 and the DRAFT Statement of Work attached to this Sources Sought posting. Thus, the contractor shall remove and reinstall the original thermal linings of the facility as deemed fit to meet the NFPA 1403 Standard. Provide a comprehensive debriefing to the end user with reports that determine all findings. Provide a Certificate of inspection that is valid for 5 years. As well as cleaning and returning all areas of work back to original condition prior to inspection.

The result of this market research will contribute to determining the method of procurement.

There is currently no incumbent. This is a new requirement.

The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 541350 - Building Inspection Services.

If you are interested in this requirement, please see attached "Sources Sought Bldg 639" document for more information.

Update #1 ·

SOURCES SOUGHT

THIS IS NOT A SOLICITATION! This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary and the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.

The 319th Contracting Squadron, Grand Forks AFB, North Dakota, is issuing this Sources Sought as a means of conducting market research to identify parties having the resources to provide the following:

The Contractor shall provide all materials, plans, travel, labor, equipment, and supervisory staff necessary to be capable of inspecting the non-gas fired live fire training structure of Building 639, located at Grand Forks AFB. Said supervision shall be done in accordance with the requirements of NFPA 1403, 2018 Edition, Chapter 7 and the DRAFT Statement of Work attached to this Sources Sought posting. Thus, the contractor shall remove and reinstall the original thermal linings of the facility as deemed fit to meet the NFPA 1403 Standard. Provide a comprehensive debriefing to the end user with reports that determine all findings. Provide a Certificate of inspection that is valid for 5 years. As well as cleaning and returning all areas of work back to original condition prior to inspection.

The result of this market research will contribute to determining the method of procurement.

There is currently no incumbent. This is a new requirement.

The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 541990 – All Other Professional, Scientific, and Technical Services.

If you are interested in this requirement, please see attached "Sources Sought Bldg 639" document for more information.

Files

File Type Posted
Sources Sought Bldg 639 - 6 Mar 23.pdf PDF
Sources Sought Bldg 639.pdf PDF

Notice history

Notice Type Posted
Live fire training facility inspection Latest solicitation Solicitation
This notice Pre-Solicitation
Conference room data walls Original Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Inspection of Fire Extinguishers and Suppression Systems for AMXG at Hill AFB, Utah Hill Air Force Base, Utah 84056, United States · NAICS 561621 Air Force Sustainment Center Total Small Business
Fire Alarm/Suppression Inspection, Testing, and Maintenance Rome, New York 13441, United States · NAICS 561621 Air Force Research Laboratory No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity