Laboratory Grade Water Purification System

Closed Pre-Solicitation Posted

Solicitation number
FA301625Q
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Jbsa Lackland, Texas 78236, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Air Force Air Education and Training Command's 59th Medical Wing at Wilford Hall, JBSA Lackland, Texas, is conducting a sources sought notice for two Type 1 Reagent Grade Laboratory Water Filtration Systems. The contractor will be responsible for furnishing all labor, tools, equipment, materials, and shipping necessary to deliver, install, commission, and train 59th MDW personnel on these high-purity water systems. The systems must meet stringent laboratory specifications including total organic carbon less than 50 ppb, resistivity of 18.2 MΩ, and bacterial growth less than 1000 cfu/mL to support the facility's advanced laboratory and research functions. Installation will take place in Building 4554, Room 0B601A, at the Wilford Hall Ambulatory Surgical Center. This pre-solicitation notice was posted on June 11, 2025, with responses due by June 18, 2025.

This procurement does not utilize any set-aside designations and is classified under NAICS code 33999 (All Other Miscellaneous Manufacturing) and PSC code 4610 (Water Purification Equipment). The systems must feature specific dimensions of 72"H x 30"W x 40"D with 100-liter reservoir tanks and must be capable of 24/7 continuous operation. The contractor will be required to provide comprehensive training to 25 designated government personnel and deliver a one-year warranty on the systems. Additional requirements include obtaining necessary base passes, adhering to safety regulations, and coordinating with the designated point of contact, Mr. Tracy Wilhelm. The Performance Work Statement indicates this is currently a draft solicitation, suggesting the formal procurement process is still in development.

Notice text

Sources Sought Notice Only
Please refer to the attached draft Performance Work Statement (PWS).

The 59th Medical Wing (59th MDW) at Wilford Hall, JBSA Lackland, TX, is seeking information from potential sources capable of providing two (2) Type 1 Reagent Grade Laboratory Water Filtration Systems. The contractor will be responsible for furnishing all labor, tools, equipment, materials, and shipping necessary to deliver, install, commission, and train the 59th MDW personnel on the use of these systems IAW the PWS.

The units will be installed in Building 4554, Room 0B601A, at the Wilford Hall Ambulatory Surgical Center. The systems must meet the high-purity water standards required to support the facility’s advanced laboratory and research functions.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Individual Water Treatment Device (IWTD) Laboratory Testing Natick, Massachusetts, United States · NAICS 2213 ACC Aberdeen Proving Ground No set-aside
Demineralizer, water, IO NAICS 333310 Construction and Equipment Total Small Business
SF30-RFQ_36C25627Q0042_QA_Amendment_0001 Biloxi, Mississippi 39531, United States · NAICS 541380 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
H346--Legionella Water Testing United States · NAICS 541620 Veterans Integrated Service Network 22 Service-Disabled Veteran-Owned Small Business
F103--Boiler Water Treatment Program NAICS 325998 Veterans Integrated Service Network 12 No set-aside