The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum seeks an analytical laboratory instrument capable of acquiring real-time, simultaneous multi-modal measurement data to analyze protein behavior, with proposals due September 16. The procurement is set aside for total small business.

Place of performance is West Point, New York. The instrument must acquire fluorescence, absorbance, light scattering, and pH/conductivity data through automated experiments, with automated titrations required. Temperature and mixing speed must be controllable. The instrument shall perform experiments in phase separation, protein interactions, protein aggregation, thermal stability, ion binding, and pH stability. The contractor must supply software for experiment setup and data collection, analysis software, and filter cubes. The instrument must be reproducible to enable different users to acquire consistent results and must operate with minimal running costs without reliance on proprietary consumables. The NAICS code is 334516, Analytical Laboratory Instrument Manufacturing; the PSC code is 6630, Chemical Analysis Instruments.

Notice text

3 versions

Update #3 · Latest ·

Amended to include need for analysis software and filter cubes. Amended to include Set aside code. We require an instrument that can acquire real-time data from multiple modes of measurement simultaneously to yield insight about protein behavior. The instrument should be reproducible to facilitate different users acquiring the same results ,have minimal running costs without the use of proprietary consumables, come with software to setup experiments and collect data. Automated experiments should collect fluorescence, absorbance, light scattering, and pH/conductivity data. Automated titration sare required. Temperature and mixing speed must be controllable. The instrument should perform experiments in phase separation, protein interactions, protein aggregation, thermal stability, ion binding, and pH stability

Update #2 ·

Amended to include Set aside code. We require an instrument that can acquire real-time data from multiple modes of measurement simultaneously to yield insight about protein behavior. The instrument should be reproducible to facilitate different users acquiring the same results ,have minimal running costs without the use of proprietary consumables, come with software to setup experiments and collect data. Automated experiments should collect fluorescence, absorbance, light scattering, and pH/conductivity data. Automated titration sare required. Temperature and mixing speed must be controllable. The instrument should perform experiments in phase separation, protein interactions, protein aggregation, thermal stability, ion binding, and pH stability

Update #1 ·

We require an instrument that can acquire real-time data frommultiple modes of measurement simultaneously to yield insight about protein behavior. Theinstrument should be reproducible to facilitate different users acquiring the same results,have minimal running costs without the use of proprietary consumables, come withsoftware to setup experiments and collect data. Automated experiments should collectfluorescence, absorbance, light scattering, and pH/conductivity data. Automated titrationsare required. Temperature and mixing speed must be controllable. The instrument shouldperform experiments in phase separation, protein interactions, protein aggregation, thermalstability, ion binding, and pH stability

Similar open opportunities

Opportunity Agency Set-aside Responses due
MESO QuickPlex SQ 120BT Instrument Silver Spring, Maryland 20910, United States · NAICS 334516 Naval Supply Systems Command No set-aside
Sources Sought for (ICP-OES) Spectrometer System with an Autosampler Annapolis, Maryland 21402, United States · NAICS 334516 Naval Supply Systems Command No set-aside
Handheld X-Ray Fluorescence for ERDC GSL Vicksburg, Mississippi 39180, United States · NAICS 334516 Engineer Research and Development Center No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity