L7-090 Repair and Liner - Chemical Storage Tanks

Closed Solicitation Posted

Solicitation number
FA857126Q0087
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Georgia 31098, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Air Force Sustainment Center seeks repair of an existing chemical storage tank liner and purchase of one replacement L7-090 PVDF liner, with proposals due July 2, as amended. This is a single-source Request for Quote to the Original Equipment Manufacturer under Simplified Acquisition Procedures; no competitive set-aside applies.

Place of performance is Warner Robins, Georgia (Building 20128, Robins Air Force Base). The procurement requires repair of the existing Polyvinylidene Fluoride (PVDF) L7-090 Liner on Tank 120 via AC and DC spark testing, surface preparation, and PVDF fusion welding of all visible cracks. The contractor shall supply one new L7-090 liner fabricated from approximately 5/16-inch thick Kynar 2850 Flex sidewalls and rim and 3/8-inch thick Kynar 2850 Flex bottom, incorporating patented N-FUZE lining technology with pressure butt-welded vertical joints and extrusion welded sidewall-to-bottom construction. The new liner dimensions are approximately 48 inches by 48 inches by 72 inches deep with one 45-degree corner to accommodate reinstallation of the existing TANKeye Plus Leak Detection System. Repair is scheduled four weeks after contract award as a one-day on-site visit requiring one technician. Delivery of the new liner is scheduled ten weeks after approval drawing approval, FOB Destination to Building 20128. The contractor provides a standard one-year warranty on the new liner only; no warranty covers repair work.

Award value is not to exceed $19 million. NAICS code is 238990 (All Other Specialty Trade Contractors); PSC code is J049. Contractor personnel must complete Air Force-provided Environmental Management System awareness training and all contractor personnel must be ISO 50001 certified. The contractor must submit an approval drawing within two business days of award for Government review and approval within two business days. Amendment 0001, issued July 1, accelerated the response deadline from July 10 to July 2 and extended the delivery schedule for the spare liner from six weeks to ten weeks from award. Prevailing wage rates per Service Contract Act apply (Georgia wage determination 2015-4995, Revision 31, May 13, 2026).

Notice text

2 versions

Update #2 · Latest ·

This solicitation is being conducted under Simplified Acquisition Procedures (SAP) as a Request for Quote (RFQ) No. FA857126QOO87. This requirement is being solicited as a single source requirement to the Original Equipment Manufacturer (OEM) for the repair of L7-090 Liner and purchase of one (1) additional L7-090 Liner.

The Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.

The Contractor shall provide the following:
• Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs.
• 1 each (PVDF) Kynar® Rigid Box Liner to fit CMXG’s existing tank
• Approximately 48” x 48” x 72” deep, fabricated from ¼” thick Kynar 2850 Flex sidewalls and rim and 3/8” thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System

Amendment 0001 corrects Period of Performance for CLIN 0002 and adjust responses due date to account for the High Priority need of this effort.

Update #1 ·

This solicitation is being conducted under Simplified Acquisition Procedures (SAP) as a Request for Quote (RFQ) No. FA857126QOO87. This requirement is being solicited as a single source requirement to the Original Equipment Manufacturer (OEM) for the repair of L7-090 Liner and purchase of one (1) additional L7-090 Liner.

The Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.

The Contractor shall provide the following:
• Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs.
• 1 each (PVDF) Kynar® Rigid Box Liner to fit CMXG’s existing tank
• Approximately 48” x 48” x 72” deep, fabricated from ¼” thick Kynar 2850 Flex sidewalls and rim and 3/8” thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System