Kentucky Lock Lift Pump Station Repair/Replacement

Closed Pre-Solicitation Posted

Solicitation number
W912P5-26-Q-KLSR
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Grand Rivers, Kentucky, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Corps of Engineers Engineering District Nashville is conducting market research through a Request for Information regarding the procurement of repair and replacement services for the Kentucky Lock Lift Pump Station. The procurement seeks contractor services to supply all materials, supplies, tools, equipment, transportation, supervision, quality control, and labor necessary to complete the scope of work in accordance with industry standards and specifications. Key requirements include the procurement and installation of two new pumps rated at 40 GPM with 108 feet total dynamic head, 5.0 HP, 3450 RPM, and 460/3/60 Hz specifications, as well as the installation of new pump supports to replace damaged existing supports within the lift station. The contractor must verify whether the existing Conery base can be reused without modification or replace it if necessary, and must include costs for any pumping or removal of existing waste required to safely complete the work. The deadline for responses to this Request for Information is December 29, 2025, with the notice having been posted on December 15, 2025. This is a pre-solicitation notice issued for market research purposes only, and no reimbursement will be made for costs associated with providing information.

This opportunity is designated as a Total Small Business set-aside, limiting competition to small business concerns as defined by the Small Business Administration. The scope of work also includes the repair of a Zoeller Model G7112 grinder pump rated at 7.5 HP, 3450 RPM, and 460/3/60 Hz that has been removed from service and must be restored to full functionality. The existing lift station currently contains two grinder pumps, with one having already been removed and replaced. The work falls under NAICS code 238210 for Electrical Contractors and Other Wiring Installation Contractors and is categorized under PSC code Y1KA for Construction of Dams. While specific budget or award value information is not provided in this pre-solicitation notice, interested contractors should reference the attached "Lock Wall Lift Station Pump Repairs Reference Document" for comprehensive details regarding existing utilities, specifications, and additional technical requirements associated with the project.

Notice text

Request for Information: The Government is issuing this Request for Information to determine a competitive basis for the procurement described. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey.

This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.

Requirement: Contractor shall furnish all materials, supplies, tools, equipment, transportation, supervision, quality control, and labor necessary to complete this Scope of Work.  All materials and workmanship will be manufactured and accomplished according to industry standards and specifications. For additional information, reference the attached document, “Lock Wall Lift Station Pump Repairs Reference Document”.

  1. Two (2) new pumps, 40 GPM and 108 feet TDH, 5.0 HP, 3450 RPM, 460/3/60 Hz will be procured and installed within the Lock Wall lift station. The existing pump supports within the lift station are damaged and new pump supports will need to be installed. The contractor shall also verify if the Conery base can be reused without modification. If not, the contractor will be responsible for replacing the base. Costs estimated for this work shall include any pumping/removal of existing waste in the lift station that is required to complete this task safely. Reference the provided reference document for additional details related to existing utilities associated with the lift station.
  2. The existing lift station contains two (2) grinder pumps. One of the existing pumps has been removed and replaced. The removed pump shall be repaired to full functionality. The removed pump is a Zoeller Model G7112, 7.5 HP, 3450 RPM, 460/3/60 Hz, submersible high head grinder pump complete with 2 ½ inch horizontal discharge flange that is adaptable to 3-inch, SC/SC lower seal, 7.125-inch diameter impeller complete with 25-feet power & control cable.
  3. The contractor shall repair or replace the transducer associated with the lift station pump. The currently installed transducer is precision digital PDA6420 Split Core AC Current Transducer.
  4. The contractor shall replace “in-kind” the 2” check valve inside the wet well. The existing check valve is Flomatic Check Valves Model 508 Part Number 3235.
  5. The contractor shall replace “in-kind” the 2” ball valve inside the wet well. The existing ball valve is Flomatic Ball Valves Part Number SSBV1000-20. Verify operation of the new ball valve with the extension handle.
  6. The Contractor shall perform a functionality test to ensure the system works as intended. Test procedures describing the functionality test shall be submitted to the Government for review and approval. The following functions shall be tested to verify that they are functioning as intended by design:
    • Both pumps automatically run via the transducer system.
    • Both pumps automatically run via the float system.
    • The pumps automatically switch from the transducer system to the float system if the transducer system fails.

Period of Performance: The Period of Performance shall be performed within 30 calendar days of the award date.

Place of Performance:  

Kentucky Lock Resident Office

193 Taylor Park Rd.

Grand Rivers, KY 42045

NAICS: The anticipated NAICS code for this requirement is 238210 (Electrical Contractors and Other Wiring Installation Contractors) with a size standard of $19,000,000.

Survey: Please send responses to the Market Survey to Samantha Clay at Samantha.J.Clay@usace.army.mil  and Cierra Vega at Cierra.R.Vega@usace.army.mil by 12:00PM CT on December 29, 2025.

  1. Name of Firm:
  2. CAGE:
  3. Point of Contact (include email address)
  4. Are you classified as a small business under any of the following NAICS code:
  • 238210 (Electrical Contractors and Other Wiring Installation Contractors)

      5. If this requirement is advertised, do you anticipate submitting a quote?

      6. List three (3) projects completed within ten (10) years of the date of this notice that demonstrates experience with electrical and wiring installation:

  • Project Name / General Description:

           Contract Number (if applicable):

           Dollar Amount:

  • Project Name / General Description:

           Contract Number (if applicable):

           Dollar Amount:

  • Project Name / General Description:

           Contract Number (if applicable):

           Dollar Amount:

Similar open opportunities

Opportunity Agency Set-aside Responses due
LAKE25-101-CC lift station pump repair NAICS 237110 Pacific West Region Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors