About this opportunity
The U.S. Coast Guard is seeking a contractor to provide fuel tank dialysis cleaning service for two 10,000-gallon Jet A fuel tanks located at USCG Sector Humboldt Bay in McKinleyville, California. The contractor must provide all necessary personnel, equipment, transportation, tools, materials, supervision, and services to perform the tank cleaning, including proper handling and disposal of contaminated fuel and waste. Key tasks include setting up a safety perimeter, evacuating residual fuel, preparing the tanks for confined space entry, replacing fuel filters, and conducting full tank inspections. The contractor must complete all work within 45 calendar days after receiving the notice to proceed from the government.
This solicitation is unrestricted, with no set-aside designation. The North American Industry Classification System (NAICS) code is 562910 - Remediation Services, and the Product and Service Code (PSC) is S206 - Environmental Remediation Services. There is no information provided about potential incumbents or current contractors. The government has not specified an award value or budget range for this contract.
Notice text
2 versions
Update #2 · Latest ·
1.1 BACKGROUND
Tank Dialysis Cleaning and Inspection Service for (2) 10,000-gallon AST Jet A fuel tanks located at USCG Sector Humboldt Bay.
1. SCOPE
The Contractor must provide all personnel, equipment, transportation, tools, materials, supervision, and other items and services necessary to perform fuel tank dialysis cleaning for two 10,000-gallon Jet A fuel tanks, to include proper handling and disposal of contaminated fuel/waste product in accordance with OSHA and EPA regulations.
2. TASKS
Contractor shall perform fuel tank cleaning service for two fuel tanks with the following specifications:
- Capacity: 10,000 gallons
- Design: horizontal, Circular, UL 2085
- AST Category: Category 1
- Construction: double wall, coated steel, concrete filled secondary
- Contractor tasks shall include:
- Setting up safety perimeter around job site
- Evacuating residual fuel
- Preparing tanks for confined space entry and issuing all required permitting
- Replacing fuel filters
- Full tank inspections for both tanks
- Contractor shall perform a final inspection with fuel samples taken prior to and after tank cleaning.
- Contractor shall provide a detailed, photo-documented, after service report and provide copies to the unit.
Contractor shall complete all work, deliverables and outcomes within 45 calendar days after notice to proceed is given by the Government.
SITE VISIT: Visit is scheduled for March 28th 8 AM - 2 PM. Please email Jason Turner to be added to the visitor's log.
Primary Point of Contact/Technical Representative:
Name: Jason Turner
Phone: 937-999-8584
E-mail: Jason.D.Turner@uscg.mil
Alternate Point of Contact
Name: CWO Kurtis Collins
Phone: 707-839-6163
E-mail: Kurtis.J.Collins@uscg.mil
Submit all bids to Joseph Perez Joseph.A.Perez@uscg.mil
Update #1 ·
1.1 BACKGROUND
Tank Dialysis Cleaning and Inspection Service for (2) 10,000-gallon AST Jet A fuel tanks located at USCG Sector Humboldt Bay.
1. SCOPE
The Contractor must provide all personnel, equipment, transportation, tools, materials, supervision, and other items and services necessary to perform fuel tank dialysis cleaning for two 10,000-gallon Jet A fuel tanks, to include proper handling and disposal of contaminated fuel/waste product in accordance with OSHA and EPA regulations.
2. TASKS
Contractor shall perform fuel tank cleaning service for two fuel tanks with the following specifications:
- Capacity: 10,000 gallons
- Design: horizontal, Circular, UL 2085
- AST Category: Category 1
- Construction: double wall, coated steel, concrete filled secondary
- Contractor tasks shall include:
- Setting up safety perimeter around job site
- Evacuating residual fuel
- Preparing tanks for confined space entry and issuing all required permitting
- Replacing fuel filters
- Full tank inspections for both tanks
- Contractor shall perform a final inspection with fuel samples taken prior to and after tank cleaning.
- Contractor shall provide a detailed, photo-documented, after service report and provide copies to the unit.
Contractor shall complete all work, deliverables and outcomes within 45 calendar days after notice to proceed is given by the Government.
SITE VISIT: Visit is scheduled for March 28th 8 AM - 2 PM. Please email Jason Turner to be added to the visitor's log.
Primary Point of Contact/Technical Representative:
Name: Jason Turner
Phone: 937-999-8584
E-mail: Jason.D.Turner@uscg.mil
Alternate Point of Contact
Name: CWO Kurtis Collins
Phone: 707-839-6163
E-mail: Kurtis.J.Collins@uscg.mil
Files
| File | Type | Posted |
|---|---|---|
| SOW Fuel Tank Cleaning 2023.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| CGC manta – fuel tank cleaning | — | Total Small Business | |
| H999--Underground Fuel Storage Tank Cleaning, Inspection, Testing and Re-Fueling | Veterans Integrated Service Network 21 | No set-aside | |
| Vandenberg SFB Tank Inspection | ENDIST Omaha | Service-Disabled Veteran-Owned Small Business | |
| Cleaning, Inspection, and Hazardous Waste Removal for Two 10, 000-Gallon Oil/Water Separators | Secretary of the Air Force | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity