J065--Performance Water Systems Service Agreement
Open Pre-Solicitation Posted
- Solicitation number
- 36C24627Q0117
- Agency
-
Veterans Integrated Service Network 6
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 811210 Electronic and Precision Equipment Repair and Maintenance
- Place of performance
- Richmond VA Medical Center Richmond Virginia 23249
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Network Contracting Office 6 is conducting Sources Sought market research, on behalf of the Richmond VA Medical Center, to identify qualified businesses for a Performance Water Systems Service Agreement (PSC J065, NAICS 811210), with responses due November 23, 2026. No set-aside is used. The contracting office is in Hampton, Virginia, and the place of performance is Richmond VA Medical Center in Richmond, Virginia. The contractor must furnish all labor, transportation, parts, and expertise for preventive maintenance and emergency (unscheduled) repair of water purification equipment at that facility. Preventive maintenance must be performed by the original equipment manufacturer (OEM) or an OEM-certified contractor at OEM-specified intervals, with documentation of current OEM certification and authorization. The contractor must maintain written procedures and documented evidence of inspection for each piece of equipment, and must furnish PM kits, tools, manuals, and materials. Monthly tasks include sediment filter replacement for CWP systems, Marcor portable RO units, and seven AmeriWater Centurion RO carts, plus inspection of all equipment. Quarterly tasks include sediment and carbon block filter replacement on Millenium HX and Centurion systems, and chemicals for RO membrane cleaning on CWP systems. Interested firms submit capability statements to Natasha.Hawkins@va.gov, addressing SAM registration and Unique Entity Identifier, evidence of OEM authorization or distributorship, compliance with subcontracting limitations, and related business entities.
Notice text
The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of Richmond VA Medical Center is conducting Market Research through this Sources Sought notice to help determine the availability of qualified Businesses, capable of providing service for Performance Water Systems Service Agreement that meets the following requirements:
The Contractor shall furnish all labor, transportation, parts, and expertise necessary to provide preventive maintenance and emergency (unscheduled) repair of machines of the located at the Richmond VAMC.
Preventive Maintenance:
Preventive Maintenance (PM) shall be performed by either the OEM, or a contractor certified by the OEM at intervals in accordance with the original equipment manufacturers (OEM) specifications. The contractor must provide documentation confirming current OEM certification and authorization to perform maintenance services.
Contractor shall furnish any required PM kits, tools, manuals and materials needed to perform Preventative Maintenance.
The contractor shall perform PM according to manufacturer s specifications. The contractor shall have written procedures to be followed and documented evidence that each piece of equipment has been inspected according to those procedures.
Monthly Tasks:
Replace sediment filters for CWP systems (two LD05 20 filters per visit).
Replace sediment filters for each Marcor portable RO (GX05 10 per machine).
Replace sediment filters for each AmeriWater Centurion RO cart (GX05 10 filter for each of 7 units).
Inspect all equipment for proper function.
Quarterly Tasks:
Replace (2) 20 sediment filters for CWP systems.
Replace (2) carbon block filters for each Millenium HX RO (2 systems).
Replace (1) 10 sediment filter for each Millenium HX RO (2 systems).
Provide chemicals to clean RO membranes on both CWP systems.
Replace (1) GX05 10 filter for each of the 7 AmeriWater Centurion RO carts.
Replace (2) 2.5 x 20 Chlorplus carbon blocks for 2 Centurion systems
Attachment 1: Equipment List
Manufacturer
Equipment Name
Model #:
Serial #:
Location:
Acquisition Date
Ameriwater
Water Purification Systems
Centurion
CPM21019
2H Area
08/02/2023
Ameriwater
Water Purification Systems
Centurion
CPM21020
2H Area
08/02/2023
Ameriwater
Water Purification Systems
Centurion
CEN240015
2H Area
05/09/2024
Ameriwater
Water Purification Systems
Centurion
CEN240013
2H Area
05/09/2024
Ameriwater
Water Purification Systems
Centurion
CEN240009
2H Area
05/09/2024
Ameriwater
Water Purification Systems
Centurion
CEN240012
2H Area
05/09/2024
Ameriwater
Water Purification Systems
Centurion
CEN240007
2H Area
05/09/2024
Marcor
Millenium
HX
1369448
2H Area
09/07/2018
Marcor
Millenium
HX
1369426
2H Area
09/07/2018
Marcor
CWP
CWP
1369449
Water Room
04/01/2018
All respondents shall indicate/provide the following:
Must demonstrate the ability to comply with the limitations on subcontracting in RFO 52.219-14 / VAAR 852.219-75, as applicable. In your capability statement, describe how your firm intends to comply with this limitation throughout performance.
Is your company interested in providing a Federal Supply Schedule (FSS) quote or Open Market (indicate FSS contract #)?
Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services under the same or a related NAICS codes.
Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each.
Whether or not your company has an active SAM registration and the companies Unique Entity Identifier.
A copy of its capabilities statement.
Failure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs.
If the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered technically acceptable.
The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than November 23, 2026, at 5:00 PM EST to the attention of: Natasha.Hawkins@va.gov
Please title the subject line for responses as: Performance Water Systems Service
Files
| File | Type | Posted |
|---|---|---|
| 36C24627Q0117.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 4610--FY27 Portable Reverse Osmosis (RO) Water Purification System | Veterans Integrated Service Network 8 | No set-aside | |
| J065--RO Equipment Maintenance RFQ Amendment to Answer Industry Questions | Veterans Integrated Service Network 10 | No set-aside | |
| Water Treatment Services | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business | |
| F103--D and D laboratory steam & water testing | Veterans Integrated Service Network 6 | No set-aside | |
| AFIT/ENG-Cleanroom DI-RO Type I Ultra-Pure Water System | AFLCMC Wright Patterson AFB | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity