J065--Nurse Call Systems Maintenance

Closed Special Notice Posted

Solicitation number
36C24126Q0857
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs, Networking Contracting Office (NCO 01) in Providence, Rhode Island issued a sole-source procurement notice on October 8, 2026 for nurse call systems maintenance at Providence VA Medical Center, with responses due by October 13, 2026 at 12:00 PM Eastern Time. The intended awardee is SIGNET Electronic Systems, LLC, the only authorized Rauland Responder distributor in the New England region with full factory warranty privileges.

The contractor shall provide preventative and corrective maintenance with next business day service, including labor, mileage, and trip charges. Scope includes biannual functional assessments of Responder 4, 4K, 5, and 5K systems across multiple building locations, with detailed reports and remediation proposals. The base year requires upgrading ED and OR/Clean Core/PACU systems from Responder 4 to Responder 5K and adding nurse call components to three rooms for clinical compliance; all labor, materials, programming, and engineering are included. The contractor must provide electronic service reports within 24 hours of work completion and be located within 60 miles of the medical center. The contract runs one base year plus four one-year option periods.

Interested parties must submit capability statements demonstrating service capabilities to Contract Specialist Rosangela Pereira at Rosangela.Pereira@va.gov. The solicitation number is 36C24126Q0857; NAICS code is 541513 and PSC code is J065.

Notice text

The Department of Veterans Affairs, Networking Contracting Office (NCO 01) located in Providence, RI intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with SIGNET Electronic Systems, LLC for the following requirement:

Performance Work Statement

Nurse Call Systems Maintenance

Summary/Requirements:

The contractor shall provide preventative and corrective maintenance on the nurse call systems installed at the Providence VA Medical Center in the following locations:

Building 1/Area

Responder Version

ED

Responder 4

OR/Clean Core/PACU

Responder 4

Hemo/ICU

Responder 5

3B

Responder 5

4A

Responder 5K

4B

Responder 5

5B

Responder 5

6A

Responder 5

6B

Responder 5

B-39

Responder 5

MRI Addition (In Construction)

Responder 5

The scope of service provided is as follows:

The contractor shall provide next business day service. Labor, mileage, and trip charges shall be included.

The contractor shall perform a biannual functional assessment of each system outlined above and shall provide a report outlining the satisfactory/unsatisfactory test status of each system and end device. A follow-on plan with associated proposal for parts necessary to return the system to fully satisfactory condition shall be provided to the customer. Labor, mileage, and trip charges associated with the above outlined repairs will be included in the service contract.

Base year will include the upgrade of the ED and OR/Clean Core/PACU Responder 4 systems to Responder 5K to allow the systems to be fully supported into the future. This process includes all labor, materials, programming and engineering by the contractor to satisfy this requirement.

Base year will include the addition of nurse call components necessary to bring rooms 460, 469, and 485 into clinical compliance for nurse call. This process includes all labor, materials, programming and engineering by the contractor to satisfy this requirement.

The contractor shall provide an electronic service report for all preventative and repair work whether scheduled service or call-in repair work within 24 hours of the completion of the work order.

Qualifications of Contractors

The contractor shall be within 60 miles of the Providence VA Medical Center.

The contractor shall be factory authorized and entitled to supply, install, and service the Rauland Responder 4, 4K, 5, and 5K nurse call systems and have full factory warranty privileges.

Place of Performance

VAMC Providence

830 Chalkstone Avenue

Providence, RI 02908

Period of Performance

The contract period of performance is one-year base period plus four one-year option periods.

The NAICS code for this requirement is 541513.

SIGNET Electronic Systems, LLC is the only authorized Rauland Responder Nurse Call distributor that can supply, install, service, and has full warranty privileges in the New England region. SIGNET is authorized to supply, install, and service the Rauland Responder 4, 4K, 5, and 5K nurse call systems and have full factory warranty privileges.

This notice of intent is not a solicitation nor is it a request for proposal. However, all responsible sources may submit a capability statement demonstrating the ability to provide the requested services, in writing by Tuesday, October 13, 2026 at 12PM EST. Responses should be sent to Rosangela Pereira at Rosangela.Pereira@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government.