J065--BrainLab ExacTrac Base 4OY Service

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
36C25925Q0079
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Department of Veterans Affairs Oklahoma City VA Medical Center Oklahoma City, Oklahoma 73104, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs (VA) is seeking a contractor to provide continued support and service of the Brainlab Exactrac system at the Oklahoma VA Health Care System (OKCVAMC). The contractor will be required to perform all services in accordance with the Performance Work Statement (PWS) and to Original Equipment Manufacturer (OEM) standards, ensuring 95% uptime for the government-owned equipment. Services include preventive maintenance, software updates, and repair/replacement of parts. The contractor must provide OEM-trained technicians and use only OEM-standard or certified parts. Responses to the Sources Sought notice are due by 3:00 PM Central Time on 11/20/2024. This is a market research notice only, and no award will be made from this posting. The VA is interested in the socioeconomic status of interested companies, their subcontracting plans, and whether they hold relevant GSA/FSS contracts.

The contract is set aside for Service-Disabled Veteran-Owned Small Businesses. The VA did not provide information on any potential incumbents or current contractors. The contract period is a base plus 4 option years, but the VA did not specify an estimated award value or budget range. The VA is seeking to procure services related to the maintenance and repair of the Brainlab Exactrac radiation therapy positioning and monitoring system, which is government-owned equipment.

Notice text

BrainLab ExacTrac System service for the OKCVAMC base + 4 contract

PURPOSE:

Veterans Affairs requires a contractor to provide continued support and service of the Brainlab Exactrac system at the Oklahoma VA Health Care System. Services are to be performed in accordance with this PWS and to OEM standards, with the intent of ensuring the equipment operates as the original manufacturer intended, uninterrupted (95% uptime), in a cost-effective, efficient manner, contributing to the VA Mission.

Services are required on the government-owned systems listed in this PWS for the period of performance and at the location outlined in this PWS.

This Contract will be a non-personal services contract. The Contractor, its employees, agents and subcontractors shall not be considered government employees for any purpose. Contractor shall furnish all labor, materials, parts, equipment, tools, transportation, and supervision to provide services in accordance with this Performance Work Statement (PWS).

BACKGROUND:

Equipment: The following systems of equipment require service under this contract. This includes sub-systems, components, software, hardware, and parts.

Equipment

Description

Brand & Model

Original Equipment Manufacturer (OEM)

Serial Number

VA

PMI Number

Radiation Therapy Positioning and Monitoring System

Exactrac System

Brainlab

Tasks and Requirements

Performance and Repairs: All work performed shall be in accordance with manufacturer s specifications, including but not limited to adjustments, calibrating, cleaning, lubricating, testing, disassembly, checkout, replacement of parts, etc. required to keep the equipment in operating condition. Contractor must guarantee 95% up time for the equipment. Contractor shall guarantee that all equipment covered by this contract shall be in optimum working condition at the completion of each contracted Period of Performance. Contractor will make every attempt to maintain and repair equipment on-site within a reasonable time, unless local environment prohibits on-site attendance. Failing this, contractor will provide substitute equipment in the event a repair continues beyond the reasonable time frame.

A reasonable time frame ensures the VA mission continues uninterrupted with no loss, damage or suffering to VA patients and resources.

Preventive Maintenance: Contractor shall provide periodic preventive maintenance service on equipment within the interval(s) set by the OEM (ie, Annual, Semi-Annual, Quarterly), in scheduled month of each contracted Period of Performance, including all work between Standard Business Hours, weekend hours, and non-standard hours, and arranged through the COR. The contractor shall work with the COR, Surgery service and Sterile Processing Service to not disrupt patient care by scheduling PM visits in advance. The visits will include equipment verification by an OEM-trained technician. Before the expiration of each period of performance, the contractor shall provide the COR with a report certifying the equipment listed in this PWS has been calibrated to O.E.M. standards not less than OEM recommended interval(s) during the contract period. All parts shall be O.E.M. standard or certified.

Software Updates: Contractor shall provide any software updates, as they become available, for all equipment, at no additional cost. All software changes made become the property of the VA.

Modifications: If contractor or external hazard assessment/notification by the FDA, NCPS, or CEOSH determines that a modification is necessary to address safety concerns or reliability, installation and modification will be performed at no additional charge.

Parts: As part of the OEM-standard of service required on this contract, contractor must provide unique and/or high mortality replacement parts. All parts will be O.E.M. recommended parts. Contractor must provide repair services on batteries and handpieces, at no additional cost to the government. This includes provision of replacement/loaner parts and shipment costs, such as loaner handpieces. To maintain continuity of patient care, contractor must ship replacement/loaner handpieces overnight to the VA within 48 hours of receipt of notice by the VA that a hand piece needs to be repaired due to normal wear and tear. Once the loaner is received by the VA, the VA will ship the government-owned hand piece to the contractor.

If the government-owned hand piece is not able to be repaired the contractor must return the broken handpiece to the VA with written notification of what prevented the repair and the issues causing the part not to function the way the OEM intended.

QUALITY

Conformance Standards

Contractor shall ensure that their services, staff and equipment used in the performance of this contract conform and comply with the latest industry service standards, information, guidance, regulations and publications of the following:

AAMI-ANSI ST-79:2010 Part 7.7 standards (Servicing and Repairs of Devices in the Health Care Facility). This can be obtained at http://www.aami.org/publications/standards/st79.html

IAHCSMM - International Association of Healthcare Central Service Materiel Management

US FDA US Food and Drug Administration

CDC Centers for Disease Control and Prevention

CDRH Center for Devices and Radiological Health

ISO (As a minimum: ISO 9001:2008 Certification and ISO 13485:2003 certification (medical devices))

ASQ American Society for Quality

UL Underwriters Laboratories

OSHA Occupational Safety and Health Administration

TECHNICAL QUALIFICATIONS and PERSONNEL STANDARDS

Calibration of Vendor s Equipment: Contractor must provide the COR with certification attesting that all gauging and measurement equipment used to check and calibrate the subject items of equipment has been calibrated either according to the manufacturer s specifications or within the last twelve months against a standard that is traceable to the National Bureau of Standards.

Qualifications of Contractor OEM-Trained Technicians: Contractor shall document, in writing, their experience in working on the identical make and model equipment listed in this PWS as well as the qualifications of individuals who will work on the equipment. Where the PWS requires OEM-trained technicians, demonstration of this will also be required in the documentation.

BRIEF SCOPE OF WORK

(This is for information only)

IMPORTANTR NOTE: This Sources Sought is for information only (to determine the socioeconomic status of interested companies). No award will be made off of this posting.

LIMITATIONS OF SUBCONTRACTING: The Limitations of Subcontracting may or may not apply to a resulting solicitation from this Market Research. Vendors are advised to familiarize themselves with Federal Acquisition Regulation parts 19.505(a)(2) and 19.505(b)(1) as it pertains to subcontracting limitations. Vendors are also advised to familiarize themselves with 13 CFR 125.6 and the penalties described in this regulation.

Please communicate via e-mail to jeffery.eller@va.gov by 3:00PM, 11/20/2024 as to your company s interest and ability to perform service per this brief Scope of Work.

If interested, please provide the following:

Please state your company s business size as related to NAICS code 811210:________________

As per the Limitations of Subcontracting: (see FAR 19.505)

As Primary Contractor: what % of Total Contract Value will you retain?___________

If using a Subcontractor: what % of Total Contract Value will go to them?__________

Please provide SAMs Unique Entity Identifier number:_____________

If you have an FSS/GSA contract that includes this service:____________

Provide FSS/GSA contract number if applicable:________________

IF YOU ARE NOT INTERESTED, NO RESPONSE IS NECESSARY

Files

File Type Posted
36C25925Q0079_1.docx DOCX document

Notice history

Notice Type Posted
J065--BrainLab ExacTrac Base 4OY Service Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
J065-- Carestream Portable X-ray Service Base plus Four Department of Veteran Affairs Birmingham AL 35233, United States · NAICS 811210 Veterans Integrated Service Network 7 Total Small Business
J065--Full-service Preventative Maintenance on Siemens Symbia S NAICS 811210 Veterans Integrated Service Network 19 No set-aside
J065- Q2 SERVICES (BASE+4) Globus NYH Service Contract (VA-27-00004429) NAICS 811210 Veterans Integrated Service Network 2 No set-aside
6515--NX EQ Image Guided Surgical Navigation System (VA-26-00083972) Nationwide · NAICS 334510 VA Strategic Acquisition Center Frederick Service-Disabled Veteran-Owned Small Business
36C255-27-AP-0365 - CT Contrast Injector Maintenance Services Marion, Illinois 62959, United States · NAICS 811210 Veterans Integrated Service Network 15 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity