J059--MCC & Panelboards Replacement
Closed Pre-Solicitation Posted
- Solicitation number
- 36C25026Q0576
- Agency
-
Veterans Integrated Service Network 10
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Department of Veterans Affairs Richard L. Roudebush VA Medical Center Indianapolis IN 46202 U.S.A.
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Integrated Service Network 10 is issuing a Sources Sought notice for electrical equipment replacement services at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana, with responses due May 22, 2026 at 5:00 PM Eastern Time.
The requirement involves replacement of two existing motor control centers (MCCs) in the NW electrical equipment room with free standing panelboards and circuit breakers, and consolidation of two existing panelboards and cabinets into one consolidated panelboard in room C-B019. All work occurs within Building 1 at 1481 W. 10th Street, Indianapolis, Indiana 46202. Contractor shall provide and install new Eaton cabinets and Eaton circuit breakers, remove old equipment, and ensure the completed installation matches or exceeds existing voltage rating, ampacity, interrupting capacity, and number of operable circuits without reducing system capacity, reliability, or operational functionality.
Qualified contractors must demonstrate a minimum of five years documented experience performing MCC, switchgear, or panelboard replacements in occupied facilities; at least three completed projects within the last five years at 480 VAC or higher; demonstrated experience in healthcare or mission-critical facilities; capability for phased replacements with minimal interruption; valid Indiana electrical contractor license; and no serious or repeat OSHA violations related to electrical safety within three years. All contractors must be registered with SAM.gov. Small business, SDVOSB, or VOSB concerns claiming such status must meet respective SBA registration requirements.
NAICS 238210 (Electrical Contractors) applies with a $19.0 million business size standard. PSC J059 (Maintenance, Repair, and Rebuilding of Electrical and Electronic Equipment Components) governs the classification. This is market research only; no obligation or commitment exists at this time. Responses should address company name and address, point of contact information, SAM Unique Entity ID, socioeconomic status, and relevant past performance data, directed to jeffrey.rozema@va.gov with contracting officer contact at the Network Contracting Office, Battle Creek, Michigan.
Notice text
This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time.
This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine the interest and capability of businesses to meet the requirements listed below, with an emphasis on small business concerns.
Description of Requirement:
The Richard L Roudebush VA Medical Center has a requirement to replace two existing motor control centers (MCCs) in the NW electrical equipment room with free standing panelboards and circuit breakers. The project also includes the replacement of two existing panel boards and cabinets with one consolidated panelboard in room C-B019. The work includes the removal of the old cabinets and circuit breakers from both locations and the provision and installation of new Eaton cabinets and Eaton circuit breakers. The contractor shall be responsible for providing a complete and operational system consistent with the existing electrical distribution. Replacement shall match or exceed the existing system in voltage rating, ampacity, interrupting capacity and the number of operable circuits. The completed installation shall not reduce system capacity, reliability or operational functionality.
All work will occur at the Richard L. Roudebush VA Medical Center (RLRVAMC), 1481 W. 10th Street, Indianapolis, IN 46202. All work will occur in the interior of Building 1 on campus. RLRVAMC is a one million+ square foot medical facility consisting of several buildings that provide both inpatient and outpatient care and services. This is a fully functioning hospital that provides medical care 24 hours per day, every day of the year. Interruption of electrical services would significantly impair the ability of the hospital to continue to provide services to veterans. Upmost care is required during all work on electrical systems to minimize any disruptions to care. All work shall be planned and executed to avoid unplanned outages. Disruptive testing or power curtailment work shall be completed during off hours.
Contractor Qualifications:
The contractor shall be a firm regularly engaged in the installation, modification, and replacement of electrical distribution equipment of similar size, complexity and voltage class, and
Have a minimum of five years documented experience performing MCC, switchgear or panelboard replacements in occupied facilities, and
Can show at least three completed projects within the last five years involving MCC or switchgear replacement with voltages 480 VAC, and
Can demonstrate previous work in healthcare, laboratory or mission-critical facilities, and
Possess demonstrated experience performing phased replacements and maintaining partial system operation with planned outages and tie-ins with minimal interruption, and
Have no record of OSHA serious/repeat violations within the last three years related to electrical safety, and
The contractor shall hold a valid electrical contractor license in the state of Indiana, and
The contractor shall demonstrate experience working in occupied healthcare facilities requiring strict outage coordination and operational continuity.
The associated North American Industry Classification System (NAICS) Code is 238210 Electrical Contractors and Other Wiring Installation Contractors, and the Business Size Standard is $19.0M. The associated Product Service Code is J059 Maintenance, Repair, and Rebuilding of Equipment Electrical and Electronic Equipment Components.
Requested Information:
To aid acquisition planning, contractors that are interested and capable of meeting this requirement are asked to provide a response via the email address listed below. Please provide at minimum the following information in your response:
(1) Business name and address
(2) Point of contact name, phone number and e-mail address
(3) SAM Unique Entity ID (UEI)
(4) Socio-economic status
(5) Any relevant past performance and/or capability information
Additional information:
All contractors must be registered with the System for Award Management (SAM) at https://sam.gov.
Any contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.103.
Any contractor that believes they are capable and desires to claim preference for SDVOSB or VOSB status must be registered with the SBA Veteran Small Business Certification Program.
Responses due to the Contracting Officer, Jeffrey Rozema, by Friday, May 22, 2026, at 5:00 PM Eastern Time. Please e-mail all responses to jeffrey.rozema@va.gov.
Files
| File | Type | Posted |
|---|---|---|
| 36C25026Q0576.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA--Project No. 583-22-106- Replace Electrical Panels & Expand Distribution. | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| J061--Sources Sought Emergency Switchgear Repairs 539 | Veterans Integrated Service Network 10 | No set-aside | |
| H312--Fire Alarm Maintenance Service Contract FY27 - NEW Base + Four - 583 | Veterans Integrated Service Network 10 | No set-aside | |
| C211--589A6-24-410, Replace MDP Panel Bld 89| EKH | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--NRM| 460-26-007 Electrical Distribution Inspection Repairs | NCO 4 Construction East (VA-26-00057558) | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity