J059--EMERGENCY LOW VOLTAGE (480) SOURCE SWITCHGEAR and AUTOMATIC TRANSFER SWITCH (ATS) AND THE UTILITY LOW VOLTAGE (480) SOURCE SWITCHGEAR AND ATS
Closed Solicitation Posted
- Solicitation number
- 36C24726Q0680
- Agency
- Veterans Integrated Service Network 7 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 335313 Switchgear and Switchboard Apparatus Manufacturing
- Points of contact
-
- Marcus Watts marcus.watts@va.gov (334) 727-0550
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Integrated Service Network 7 seeks annual preventive maintenance on Emergency Low Voltage (480) and Utility Low Voltage (480) switchgear and automatic transfer switches at Ralph H. Johnson VA Medical Center in Charleston, South Carolina, with proposals due August 4, 2026. This is a 100 percent Service-Disabled Veteran-Owned Small Business set-aside with a 50 percent maximum subcontracting limitation for services.
Place of performance is Ralph H. Johnson VA Medical Center, Charleston, South Carolina. Work includes inspection, cleaning, calibration, and testing of ISO parallelling switchgear with Asco ATS units and Eaton Circuit Breakers (Emergency Low Voltage system) and Eaton parallelling switchgear with Eaton circuit breakers (Utility Low Voltage system), including 12 Automatic Transfer Switches per system, Master Control Cubicles, Generator Control Cubicles, and Fire Pump ATS units. Services must comply with NFPA-99, NFPA 110, UL, OSHA, and VA standards, performed by OSHA-trained personnel with manufacturer certification and calibration equipment. Only foremen and supervisors require initial PIV credential issuance; contractor personnel may access the site under escort during credentialing processing. The base period runs September 1, 2026 through August 31, 2027, with four one-year option periods. Work is limited to normal business hours Monday–Friday, 7:00 AM to 3:30 PM, with provisions for scheduled emergency outside-hours service requiring at least two weeks' advance notice. Offerors must submit a Certificate of Compliance at time of offer and comply with prevailing wage requirements per Department of Labor Wage Determination 2015-4427. Site visits are available between July 27 and August 3, 2026. The NAICS code is 335313, and the PSC is J059.
Notice text
N/a
Attachments
| File | Type | Posted |
|---|---|---|
| 36C24726Q0680 0001.docx | DOCX document | |
| 36C24726Q0680.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| J059--EMERGENCY LOW VOLTAGE (480) SOURCE SWITCHGEAR and AUTOMATIC TRANSFER SWITCH (ATS) AND THE UTILITY LOW VOLTAGE (480) SOURCE SWITCHGEAR AND ATS | Solicitation | |
| J059--EMERGENCY LOW VOLTAGE (480) SOURCE SWITCHGEAR and AUTOMATIC TRANSFER SWITCH (ATS) AND THE UTILITY LOW VOLTAGE (480) SOURCE SWITCHGEAR AND ATS | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity