J041--Chiller Plant/ ARF Services Contract

Closed Pre-Solicitation Posted

Solicitation number
36C24226Q0208
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Stratton VA Medical Center Albany, New York 12208, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This is a Sources Sought Notice issued by the Department of Veterans Affairs Veterans Health Administration, Veterans Integrated Service Network 2, seeking to identify potential contractors capable of providing comprehensive maintenance, operation, and repair services for chiller plant and operating room cooling systems at the Stratton VA Medical Center in Albany, New York. The procurement covers complex cooling equipment including one 750-ton and two 1000-ton Trane centrifugal chillers, three cooling towers, variable frequency drives, and associated OR chillers located in Building #54 and the Main Hospital sub-basement. Key requirements include preventive maintenance, 24-hour emergency response capabilities, annual equipment testing, tower cleanings, valve and actuator maintenance, and year-round cooling season support. The evaluation will focus solely on determining the appropriate acquisition strategy, with contractors required to submit a capabilities statement attesting to proper certification in accordance with the Performance Work Statement. The submission deadline is 10:00 AM EST on December 22, 2025, with interested contractors directed to email natalie.acevedo@va.gov with company information, a brief capability overview, and certification documentation.

This Pre-Solicitation Notice contains no set-aside designation and does not identify any current incumbent contractors. No award value or budget range has been specified in this market research announcement, as no formal solicitation document currently exists and no contract will be awarded from this notice. The procurement falls under NAICS Code 238220 (Plumbing, Heating, and Air-Conditioning Contractors) and Product Service Code J041 (Maintenance/Repair/Rebuild of Refrigeration, Air Conditioning, and Air Circulating Equipment). Respondents are advised that this notice is for information and planning purposes only and does not constitute a commitment by the Government, nor will contractors be notified of evaluation results. The Government will use responses to evaluate the available contractor pool and determine the most appropriate acquisition strategy for this specialized HVAC maintenance requirement.

Notice text

This is a SOURCES SOUGHT NOTICE for market research purposes only to determine the

availability of potential businesses with capabilities to provide the service described in the

Statement of Work (SOW) / Performance Work Statement (PWS). Potential offerors are invited to provide information via e-mail to

natalie.acevedo@va.gov. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition according to Performance Work Statement (PWS).

Potential contractors shall provide, at a minimum, the following information to

natalie.acevedo@va.gov:

1) Name, address, point of contact name, phone number, and e-mail address.

2) Brief capability statement with enough information to determine if the company can meet the requirement. The Capabilities Statement for this sources sought is not expected to be a Request for Quote (RFQ) nor does it restrict the Government to an ultimate acquisition approach but rather provide a short statement regarding the company's ability to provide the services as detailed in the Statement of Work. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement.

3) Statement attesting, they are properly certified in accordance with the SOW/PWS.

The capabilities will be evaluated solely for the purpose of determining the appropriate

acquisition strategy for this requirement. The Government must ensure there is an adequate competition among the potential pool of available contractors using SBA website.

This synopsis is for information and planning purposes only and is not to be construed as a

commitment by the Government nor will the Government pay for information solicited. This

synopsis is not a solicitation announcement for Request for Quote (RFQ). No formal solicitation

document exists at this time, and no contract will be awarded from this announcement.

Respondents will not be notified of the results of the evaluation. Interested contractors should respond via email by 10:00 AM (EST) on December 22, 2025.

PERFORMANCE WORK STATEMENT SUMMARY:

General: The Stratton VA Medical Center in Albany New York is seeking services for Central Chiller Plant and OR Chillers operation, maintenance and repair services. The intent is to cover preventive maintenance and repairs on all Main chiller plant equipment and OR chillers in the inventory listed below, as stipulated in this performance work statement.

Description of Services/Introduction: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform Chiller Maintenance and repairs Service as defined in this Performance Work Statement except for those items specified as government furnished property and services. The contractor shall meet the standards in this contract.

Equipment:

Main chiller Building # 54 Maintenance, Operation, Inspection, Repair.

1) 1 Trane Centrifugal Chiller 750-ton 1000# R-123

2) 2 Trane Centrifugal Chiller 750-ton 1000# R-123

3) 3 Trane Centrifugal Chiller 1000-ton 1700# R-123

4) Main Chiller Building Roof Cooling tower #1 BAC Model 3604A-2

5) Main Chiller Building Roof Cooling tower #2 BAC Model 3604A-2

6) Main Chiller Building Roof Cooling tower #3 BAC Model 3456C-2

7) Variable Frequency Drives

8) Equipment from Attachment A, B,C, D chiller plant inventory

Main Hospital Sub basement OR Chiller Maintenance, Operation, Inspection, Repair.

OR Chiller 1

Manufacturer: Trane

Model: RTUD110F

Serial: U22J03995

OR Chiller 2

Manufacturer: Trane

Model: RTUD110F

Serial: U22J03994

Variable Frequency Drives

Equipment from Attachment B OR /ARF plant inventory

Objectives: This contract will produce a tangible, implementable solution that assures safe efficient operation and maintenance of the Main Hospital chiller plant and OR Chillers Listed in the inventory at the Stratton VA Medical Center.

Scope: Services to be provided are:

Preventive Maintenance schedule sees attachment C

Covered items main chiller plant Valves, actuators, pumps, motors, vfd, see attachment A

Covered items OR chiller plant Valves, actuators, pumps, motors, vfd, see attachment B

Covered items ARF Chiller stated in attachment A

All services currently covered under the existing contract 47QSWA20D002A/ MOD 47QAWA20D002A

Chiller Operation / Automation

Repairs Normal PM s and 24-hour emergency response to alarms and equipment failures called in by FMS personnel

Operation integrity

Eddy Current testing on a 3-year basis option year 2 2029 See attachment D

Year-Round cooling season

(2) Tower cleanings per year for Towers 1-2

One Tower Cleaning per year for Tower 3

Annual cleaning of plate and frame heat exchanger

DISCLAIMER

This Sources Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

Files

File Type Posted
36C24226Q0208.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
4120--rental of two chillers for one year Asheville, North Carolina 28805, United States · NAICS 238220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business
Z2NZ--Turn Key Chiller Equipment (Purchase and Install) Pineville, Louisiana 71360, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
J041--Supply - Upgrade Chiller 3 Controls - NWI Grand Island VA Medical Center Grand Island NE 68803, United States · NAICS 238220 Veterans Integrated Service Network 23 No set-aside
C221--402-27-001 Repair Chiller 3 (AE) Veterans Affairs Medical Center Augusta ME 04330, United States · NAICS 541330 Veterans Integrated Service Network 1 Service-Disabled Veteran-Owned Small Business
J041--Condenser Coils Replacement for the VA Illiana Health Care System (VAIHCS), located at 1900 E. Main Street, Danville, IL 61832. See Solicitation · NAICS 238220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity