About this opportunity
This pre-solicitation notice seeks maintenance services for 19 freezers located at various research facilities of the Kansas City VA Medical Center. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15 is requesting semi-annual inspections and preventative maintenance, including calibration of temperature controls, cleaning of condenser coils, inspection of doors and hinges, electrical systems testing, and replacement of defective parts according to the contract. Responses are due by January 8, 2024.
The opportunity is set aside for total small businesses. The predominant NAICS code is 811412 for appliance repair and maintenance services. Contractors will provide maintenance for freezers ranging in temperature from -80 to -120 degrees Celsius. Key requirements include coordination with research budget staff, following VA equipment standards, and safety protocols for potential bloodborne pathogen exposure.
Notice text
FREEZER MAINTENANCE
STATEMENT OF WORK - RESEARCH SERVICE
Provide a minimum of two inspections per year. During these inspections complete the following for the 19 freezers ( -80Cs):
Check calibration of temperature controls and make necessary adjustments.
Check heat exchanger temperature to determine proper operation when applicable.
Run amperage draw on compressor to check with name-plate specifications.
Check cycle timer when applicable.
Clean condenser coil.
Check proper operation of door enclosures and hinges.
Check all electrical connections and contactors.
Check calibration of temperature recorder(s).
Provide equipment logs.
Provide to management the Inspection Report which lists conditions that need attention, their priority rating and estimated budget amounts.
Replace defective parts as needed based on contract agreement during the visit.
Contractor Check-in The contractor s representative will schedule all work for Research Service. Contractor s representative will contact the Budget Analyst in Research at 816-861-4700 ext. 57062 or 52755 prior to performance of services.
Contractor shall provide all parts (If any parts are not covered reference them in the quote), tools, test equipment, software, labor, travel, and equipment necessary to provide inspections, perform preventive maintenance for the below -80s -degree freezers located in the Kansas City VAMC Research department. This work shall be accomplished on a semi-annual basis.
Contractor shall ensure that equipment serviced by this contract follows the most up-to-date published edition of the applicable VA standards. The contractor will be responsible to ensure that Contractor Employees providing work on this contract are fully trained, accredited and completely competent to perform the required work. Equipment used in performance of the contract by Contractor Employees will function in conformance with the latest published edition of the applicable industry standards.
Defective parts must be replaced according to contract agreement. If another trip is required Provide in advance quote for the services.
The contractor s filed service employee shall always wear visible identification while on the premises of the VA Medical Center. Smoking is prohibited inside of buildings and only allowed in designated areas. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search, Violation of the VA regulation may result in citation answerable in the United States (Federal) District Court.
All vehicles will be locked, and the keys removed while performing service on the Medical Center s property. This is intended to protect the contractor s property and provide for safety of the Medical Center s personnel. Vehicle(s) shall be identified. Parking in the appropriate designated parking areas is expected. Information on parking is available from the on-site VA Police. The VA Medical Center will not invalidate or make reimbursement for parking violations of the contractor for any condition.
In performance of this contract, the contractor shall take such safety precautions as the Contracting Officer or designee may determine to be reasonably necessary to protect the lives and health of the occupants of any building. The Contracting Officer or designee will notify the contractor of any non-compliance with the foregoing provisions and action to be taken.
There is a potential for exposure to blood-borne or other infectious material with equipment throughout the hospital. All maintenance persons must use the Universal Precautions (i.e., decontamination of medical equipment, wearing protective gloves, aprons, and goggles) during the cleaning and maintenance/repair procedures required by this contract. BSCs that have been used for work involving infectious materials must be decontaminated before HEPA filters are changed or internal repair work is done. The contractor shall post signs at the door to the laboratory indicating that decontamination is in progress and entry is limited. In addition, a warning sign should also be displayed at the face of the BSC during the decontamination procedure.
The C&A Requirements do not apply, and a Security Accreditation Package is not required.
Equipment covered by this agreement is listed in the Equipment list section of this agreement and will determine the areas covered during inspections.
Freezers (-80s) List - Research
updated 6/30/23
Â
Manufacturer
Equipment Category
Location
1
THERMO SCIENTIFIC
K-FREEZERS: BLOOD BANK
F1.113-F-KC
Â
Model: 990
Â
Â
2
FISHER CORP
K-FREEZERS: BLOOD BANK
F2.110
Â
Model: 8956
Â
Â
3
FISHER CORP
K-FREEZERS: BLOOD BANK
F2.110
Â
Model: 8956
Â
Â
4
FISHER CORP
K-FREEZERS: BLOOD BANK
F2.110
Â
Model: 8956
Â
Â
5
FISHER SCIENTIFIC
K-FREEZERS: BLOOD BANK
F2.110
Â
Model: IU1786A
Â
Â
6
THERMO FISHER
KC-FREEZER
F2.110
Â
Model: 88600A
Â
Â
7
SANYO
KC-FREEZER
F3.110
Â
Model: MDF-U51VA
Â
Â
8
Haier
KC-FREEZER
F3.110
Â
Model: DW-86L578J
Â
Â
9
New One
Â
F3.110
10
FISHER CORP
K-FREEZERS: BLOOD BANK
F4.109-F-KC
Â
Model: 8956
Â
Â
11
SO LOW ENVIRONMENTAL EQUIP
FREEZER
F4.109-F-KC
Â
Model: PR120-5
Â
Â
12
Frigidaire
KC-Freezing UNIT
F4.109-F-KC
Â
Model: LFFN15M5HWB
Â
Â
13
SO LOW ENVIRONMENTAL EQUIP
K-FREEZERS: BLOOD BANK
F4.109-F-KC
Â
Model: PV8522
Â
Â
14
MayTag Appliances
Â
F4.120-F-KC
Â
Model: MQU1554AEW L1
S/N: 11107551EC
Â
15
ISOTEMP RESEARCH, INC
KC-FREEZER
F4.120-F-KC
Â
Model: none
Â
Â
16
General Electric Appliances
KC-FREEZER
F4.108-F-KC
Â
Model:FUM17DTCRWH
Â
Â
17
THERMO SCIENTIFIC
K-FREEZERS: BLOOD BANK
F5.121-F-KC
Â
Model: 990
Â
Â
18
Fisher Scientific
FREEZER
F5.112
Â
model: 13-986-153
Â
Â
19
PANASONIC
KC-FREEZER
6.163-6-KC
Â
Model: MDF-U500VXC-PA
Â
Â
Files
| File | Type | Posted |
|---|---|---|
| 36C25524Q0098_1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| J041--36C25524Q0098 | Refrigerator and freezer maintenance | KC | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J041--Preventive and Corrective Maintenance for Ice Machines | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| 36C25227Q0048 - coolers and freezer | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business Sole Source | |
| Refrigerator-freezer, S | Medical Supply Chain | Total Small Business | |
| Refrigeration unit | Naval Supply Systems Command | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity