36C25524Q0098_1.docx

DOCX document 29 KB Posted

Attached to
J041--36C25524Q0098 | Refrigerator and freezer maintenance | KC
Solicitation number
36C25524Q0098
Issued by

About this file

This presolicitation notice and related federal contract opportunity document outline requirements for refrigerator and freezer maintenance services at the Kansas City VA Medical Center. The contracting office seeks a contractor to provide semi-annual inspections and preventative maintenance for 19 freezers between -80 and -120 degrees Celsius located in various research facilities. The contractor must check and calibrate temperature controls, clean condenser coils, inspect doors and hinges, test electrical systems, and replace defective parts according to the contract agreement. The response deadline is January 7, 2024 at 23:00 Central Time. The contractor will coordinate access with research budget staff and follow VA equipment standards and safety protocols. The opportunity is set aside for small businesses and has an NAICS code of 811412 for appliance repair and maintenance.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Presolicitation Notice Presolicitation Notice

SUBJECT*
36C25524Q0098 | Refrigerator and freezer maintenance | KC

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
66048
SOLICITATION NUMBER*
36C25524Q0098
RESPONSE DATE/TIME/ZONE
01-07-2024 23:00 CENTRAL TIME, CHICAGO, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
SET-ASIDE
SBA
PRODUCT SERVICE CODE*
J041
NAICS CODE*
811412
PLACE OF PERFORMANCE
Kansas City VA Medical Center

4801 Linwood Blvd

Kansas City MO

POSTAL CODE
64128
COUNTRY
USA

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway

Leavenworth KS 66048

POINT OF CONTACT*

Contract Specialist Ashley Schmitt ashley.schmitt@va.gov 913-946-1974

ADDITIONAL INFORMATION

DESCRIPTION

FREEZER MAINTENANCE

STATEMENT OF WORK - RESEARCH SERVICE

1. Provide a minimum of two inspections per year. During these inspections complete the following for the 19 freezers ( -80Cs):

a. Check calibration of temperature controls and make necessary adjustments.

b. Check heat exchanger temperature to determine proper operation when applicable.

c. Run amperage draw on compressor to check with name-plate specifications.

d. Check cycle timer when applicable.

e. Clean condenser coil.

f. Check proper operation of door enclosures and hinges.

g. Check all electrical connections and contactors.

h. Check calibration of temperature recorder(s).

i. Provide equipment logs.

j. Provide to management the Inspection Report which lists conditions that need attention, their priority rating and estimated budget amounts.

k. Replace defective parts as needed based on contract agreement during the visit.

2. Contractor Check-in – The contractor’s representative will schedule all work for Research Service. Contractor’s representative will contact the Budget Analyst in prior to performance of services.

3. Contractor shall provide all parts (If any parts are not covered reference them in the quote), tools, test equipment, software, labor, travel, and equipment necessary to provide inspections, perform preventive maintenance for the below -80s -degree freezers located in the Kansas City VAMC Research department. This work shall be accomplished on a semi-annual basis.

4. Contractor shall ensure that equipment serviced by this contract follows the most up-to-date published edition of the applicable VA standards. The contractor will be responsible to ensure that Contractor Employees providing work on this contract are fully trained, accredited and completely competent to perform the required work. Equipment used in performance of the contract by Contractor Employees will function in conformance with the latest published edition of the applicable industry standards.

5. Defective parts must be replaced according to contract agreement. If another trip is required Provide in advance quote for the services.

6. The contractor’s filed service employee shall always wear visible identification while on the premises of the VA Medical Center. Smoking is prohibited inside of buildings and only allowed in designated areas. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search, Violation of the VA regulation may result in citation answerable in the United States (Federal) District Court.

7. All vehicles will be locked, and the keys removed while performing service on the Medical Center’s property. This is intended to protect the contractor’s property and provide for safety of the Medical Center’s personnel. Vehicle(s) shall be identified. Parking in the appropriate designated parking areas is expected. Information on parking is available from the on-site VA Police. The VA Medical Center will not invalidate or make reimbursement for parking violations of the contractor for any condition.

8. In performance of this contract, the contractor shall take such safety precautions as the Contracting Officer or designee may determine to be reasonably necessary to protect the lives and health of the occupants of any building. The Contracting Officer or designee will notify the contractor of any non-compliance with the foregoing provisions and action to be taken.

9. There is a potential for exposure to blood-borne or other infectious material with equipment throughout the hospital. All maintenance persons must use the “Universal Precautions” (i.e., decontamination of medical equipment, wearing protective gloves, aprons, and goggles) during the cleaning and maintenance/repair procedures required by this contract. BSCs that have been used for work involving infectious materials must be decontaminated before HEPA filters are changed or internal repair work is done. The contractor shall post signs at the door to the laboratory indicating that decontamination is in progress and entry is limited. In addition, a warning sign should also be displayed at the face of the BSC during the decontamination procedure.

10. The C&A Requirements do not apply, and a Security Accreditation Package is not required.

11. Equipment covered by this agreement is listed in the Equipment list section of this agreement and will determine the areas covered during inspections.

Freezers (-80s) List - Research updated 6/30/23

Manufacturer
Equipment Category
Location
1
THERMO SCIENTIFIC
K-FREEZERS: BLOOD BANK
F1.113-F-KC

Model: 990

2
FISHER CORP
K-FREEZERS: BLOOD BANK
F2.110

Model: 8956

3
FISHER CORP
K-FREEZERS: BLOOD BANK
F2.110

Model: 8956

4
FISHER CORP
K-FREEZERS: BLOOD BANK
F2.110

Model: 8956

5
FISHER SCIENTIFIC
K-FREEZERS: BLOOD BANK
F2.110

Model: IU1786A

6
THERMO FISHER
KC-FREEZER
F2.110

Model: 88600A

7
SANYO
KC-FREEZER
F3.110

Model: MDF-U51VA

8
Haier
KC-FREEZER
F3.110

Model: DW-86L578J

9
New One

F3.110

10
FISHER CORP
K-FREEZERS: BLOOD BANK
F4.109-F-KC

Model: 8956

11
SO LOW ENVIRONMENTAL EQUIP
FREEZER
F4.109-F-KC

Model: PR120-5

12
Frigidaire
KC-Freezing UNIT
F4.109-F-KC

Model: LFFN15M5HWB

13
SO LOW ENVIRONMENTAL EQUIP
K-FREEZERS: BLOOD BANK
F4.109-F-KC

Model: PV8522

14
MayTag Appliances

F4.120-F-KC

Model: MQU1554AEW L1
S/N: 11107551EC
15
ISOTEMP RESEARCH, INC
KC-FREEZER
F4.120-F-KC

Model: none

16
General Electric Appliances
KC-FREEZER
F4.108-F-KC

Model:FUM17DTCRWH

17
THERMO SCIENTIFIC
K-FREEZERS: BLOOD BANK
F5.121-F-KC

Model: 990

18
Fisher Scientific
FREEZER
F5.112

model: 13-986-153

19
PANASONIC
KC-FREEZER
6.163-6-KC

Model: MDF-U500VXC-PA

*=Required Field
Presolicitation Notice

Presolicitation Notice

File details come from the government source that posted it. Updated .