This presolicitation notice and related federal contract opportunity document outline requirements for refrigerator and freezer maintenance services at the Kansas City VA Medical Center. The contracting office seeks a contractor to provide semi-annual inspections and preventative maintenance for 19 freezers between -80 and -120 degrees Celsius located in various research facilities. The contractor must check and calibrate temperature controls, clean condenser coils, inspect doors and hinges, test electrical systems, and replace defective parts according to the contract agreement. The response deadline is January 7, 2024 at 23:00 Central Time. The contractor will coordinate access with research budget staff and follow VA equipment standards and safety protocols. The opportunity is set aside for small businesses and has an NAICS code of 811412 for appliance repair and maintenance.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Presolicitation Notice Presolicitation Notice
| SUBJECT* |
| 36C25524Q0098 | Refrigerator and freezer maintenance | KC |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 66048 |
| SOLICITATION NUMBER* |
| 36C25524Q0098 |
| RESPONSE DATE/TIME/ZONE |
| 01-07-2024 23:00 CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| SET-ASIDE |
| SBA |
| PRODUCT SERVICE CODE* |
| J041 |
| NAICS CODE* |
| 811412 |
| PLACE OF PERFORMANCE |
| Kansas City VA Medical Center |
4801 Linwood Blvd
Kansas City MO
| POSTAL CODE |
| 64128 |
| COUNTRY |
| USA |
CONTACT INFORMATION
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway
Leavenworth KS 66048
POINT OF CONTACT*
Contract Specialist Ashley Schmitt ashley.schmitt@va.gov 913-946-1974
ADDITIONAL INFORMATION
DESCRIPTION
FREEZER MAINTENANCE
STATEMENT OF WORK - RESEARCH SERVICE
1. Provide a minimum of two inspections per year. During these inspections complete the following for the 19 freezers ( -80Cs):
a. Check calibration of temperature controls and make necessary adjustments.
b. Check heat exchanger temperature to determine proper operation when applicable.
c. Run amperage draw on compressor to check with name-plate specifications.
d. Check cycle timer when applicable.
e. Clean condenser coil.
f. Check proper operation of door enclosures and hinges.
g. Check all electrical connections and contactors.
h. Check calibration of temperature recorder(s).
i. Provide equipment logs.
j. Provide to management the Inspection Report which lists conditions that need attention, their priority rating and estimated budget amounts.
k. Replace defective parts as needed based on contract agreement during the visit.
2. Contractor Check-in – The contractor’s representative will schedule all work for Research Service. Contractor’s representative will contact the Budget Analyst in prior to performance of services.
3. Contractor shall provide all parts (If any parts are not covered reference them in the quote), tools, test equipment, software, labor, travel, and equipment necessary to provide inspections, perform preventive maintenance for the below -80s -degree freezers located in the Kansas City VAMC Research department. This work shall be accomplished on a semi-annual basis.
4. Contractor shall ensure that equipment serviced by this contract follows the most up-to-date published edition of the applicable VA standards. The contractor will be responsible to ensure that Contractor Employees providing work on this contract are fully trained, accredited and completely competent to perform the required work. Equipment used in performance of the contract by Contractor Employees will function in conformance with the latest published edition of the applicable industry standards.
5. Defective parts must be replaced according to contract agreement. If another trip is required Provide in advance quote for the services.
6. The contractor’s filed service employee shall always wear visible identification while on the premises of the VA Medical Center. Smoking is prohibited inside of buildings and only allowed in designated areas. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search, Violation of the VA regulation may result in citation answerable in the United States (Federal) District Court.
7. All vehicles will be locked, and the keys removed while performing service on the Medical Center’s property. This is intended to protect the contractor’s property and provide for safety of the Medical Center’s personnel. Vehicle(s) shall be identified. Parking in the appropriate designated parking areas is expected. Information on parking is available from the on-site VA Police. The VA Medical Center will not invalidate or make reimbursement for parking violations of the contractor for any condition.
8. In performance of this contract, the contractor shall take such safety precautions as the Contracting Officer or designee may determine to be reasonably necessary to protect the lives and health of the occupants of any building. The Contracting Officer or designee will notify the contractor of any non-compliance with the foregoing provisions and action to be taken.
9. There is a potential for exposure to blood-borne or other infectious material with equipment throughout the hospital. All maintenance persons must use the “Universal Precautions” (i.e., decontamination of medical equipment, wearing protective gloves, aprons, and goggles) during the cleaning and maintenance/repair procedures required by this contract. BSCs that have been used for work involving infectious materials must be decontaminated before HEPA filters are changed or internal repair work is done. The contractor shall post signs at the door to the laboratory indicating that decontamination is in progress and entry is limited. In addition, a warning sign should also be displayed at the face of the BSC during the decontamination procedure.
10. The C&A Requirements do not apply, and a Security Accreditation Package is not required.
11. Equipment covered by this agreement is listed in the Equipment list section of this agreement and will determine the areas covered during inspections.
Freezers (-80s) List - Research updated 6/30/23
| Manufacturer |
| Equipment Category |
| Location |
| 1 |
| THERMO SCIENTIFIC |
| K-FREEZERS: BLOOD BANK |
| F1.113-F-KC |
Model: 990
| 2 |
| FISHER CORP |
| K-FREEZERS: BLOOD BANK |
| F2.110 |
Model: 8956
| 3 |
| FISHER CORP |
| K-FREEZERS: BLOOD BANK |
| F2.110 |
Model: 8956
| 4 |
| FISHER CORP |
| K-FREEZERS: BLOOD BANK |
| F2.110 |
Model: 8956
| 5 |
| FISHER SCIENTIFIC |
| K-FREEZERS: BLOOD BANK |
| F2.110 |
Model: IU1786A
| 6 |
| THERMO FISHER |
| KC-FREEZER |
| F2.110 |
Model: 88600A
| 7 |
| SANYO |
| KC-FREEZER |
| F3.110 |
Model: MDF-U51VA
| 8 |
| Haier |
| KC-FREEZER |
| F3.110 |
Model: DW-86L578J
| 9 |
| New One |
F3.110
| 10 |
| FISHER CORP |
| K-FREEZERS: BLOOD BANK |
| F4.109-F-KC |
Model: 8956
| 11 |
| SO LOW ENVIRONMENTAL EQUIP |
| FREEZER |
| F4.109-F-KC |
Model: PR120-5
| 12 |
| Frigidaire |
| KC-Freezing UNIT |
| F4.109-F-KC |
Model: LFFN15M5HWB
| 13 |
| SO LOW ENVIRONMENTAL EQUIP |
| K-FREEZERS: BLOOD BANK |
| F4.109-F-KC |
Model: PV8522
| 14 |
| MayTag Appliances |
F4.120-F-KC
| Model: MQU1554AEW L1 |
| S/N: 11107551EC |
| 15 |
| ISOTEMP RESEARCH, INC |
| KC-FREEZER |
| F4.120-F-KC |
Model: none
| 16 |
| General Electric Appliances |
| KC-FREEZER |
| F4.108-F-KC |
Model:FUM17DTCRWH
| 17 |
| THERMO SCIENTIFIC |
| K-FREEZERS: BLOOD BANK |
| F5.121-F-KC |
Model: 990
| 18 |
| Fisher Scientific |
| FREEZER |
| F5.112 |
model: 13-986-153
| 19 |
| PANASONIC |
| KC-FREEZER |
| 6.163-6-KC |
Model: MDF-U500VXC-PA
| *=Required Field |
| Presolicitation Notice |
Presolicitation Notice
File details come from the government source that posted it. Updated .