HVAC Replacement at USCG STA Washington

Closed Solicitation Posted

Solicitation number
30252PR260000011
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Bolling AFB, District of Columbia 20032, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Coast Guard is soliciting quotes for the replacement of an HVAC system at U.S. Coast Guard Station Washington under solicitation number 30252PR260000011. The scope of work requires the contractor to perform a complete HVAC replacement including heat load calculations, removal and disposal of existing equipment, installation of new EPA-approved A2L refrigerant-based equipment (preferably R-454B), replacement of all line-sets, wiring, conduit, disconnects, and thermostats, and comprehensive system testing and commissioning. Key requirements include nitrogen purging and brazing of all refrigerant connections, pressure testing to 400 psi with a 24-hour hold, vacuum pull to 300 microns with decay testing, and Test and Balance procedures to verify correct airflows. The procurement will be awarded on a Firm-Fixed Price basis to an eligible responsive source with an active SAM.gov vendor record meeting small business size requirements. All quotes must be submitted via email to Samuel T. Salerno at Samuel.T.Salerno@uscg.mil by noon Eastern Time on April 30, 2026, with written questions also due by April 30, 2026.

This solicitation is a 100% Total Small Business set-aside utilizing NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors) with a small business standard of $19.0 million. The work is to be performed at Building 92, U.S. Coast Guard Station Washington, located at 3870 Giovannoli Street SW, Washington, DC 20032, on Joint Base Andrews. The contractor must commence work no later than seven calendar days after notice to proceed and complete all work within 21 working days from contract award. Performance and payment bonds are not required for this procurement. Site visits are strongly encouraged prior to bid submission to familiarize bidders with the existing conditions and coordinate with the Station Safety Officer and Environmental Protection Specialist.

Notice text

HVAC replacemet in accordance with the Attached SOW, to include:

a. Determine heat load calculations for the HVAC system using installed ducting system.  Use heat load calculations to determine an appropriate size/capacity for indoor and outdoor units utilizing installed ducting. Provide owner with a written copy of load calculations. If it is determined that any duct work needs to be modified, changed or resized in any way due to the heat load calculations, contractor shall provide and install. New unit shall be EPA approved A2L based refrigerant either R-454B or R-32, preferably R-454B. Contractor shall pull and entire new line-set to include new suction lines and liquid lines that run from heat pump to air handler. Contractor shall install a new liquid line drier for each circuit and locate the new liquid line drier indoors near the air handler to prevent unnecessary corrosion from outside elements.

b. Remove and dispose of the current outdoor and indoor units.  Unit will not have refrigerant in it.

c. Replace wiring and conduit from existing service disconnects to new pieces of equipment.  Replace any corroded or damaged conduit or wiring found during the demo of existing equipment. If disconnects are not fused, then contractor shall replace any and all associated disconnects with new fused ones.

d. Replace all thermostat control wiring inside and outside with new UV rated wire.  Provide and replace existing thermostat to match the system function.   

Files

File Type Posted
30252PR260000011 STA Washington HVAC Load Test - 1442.pdf PDF
SOW - STA Washington HVAC.pdf PDF
FAR Clauses.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
Or-bandon marsh NWR-bandon HVAC NAICS 238220 — No set-aside
Replacement of 10 Ton HVAC Unit, Bldg. 11, PR ANG Carolina, Puerto Rico 00979, United States · NAICS 238220 Army National Guard Total Small Business
Gwmp - arho bunker HVAC NAICS 238220 Intermountain Region Service-Disabled Veteran-Owned Small Business
Two sets of HVAC units or Mobile Ground Control Station Edwards, California 93523, United States · NAICS 238220 Shared Services Center Total Small Business
Replace HVAC Rooftop Units at Building 2275 March Air Reserve Base, California 92518, United States · NAICS 238220 Army National Guard No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity