HVAC Cooling Tower
Closed Pre-Solicitation Posted
A newer solicitation was posted. See the latest solicitation from .
- Solicitation number
- FA441826Q0008
- Agency
- Air Mobility Command Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- PSC
- 4120 Air Conditioning Equipment
- Place of performance
- Charleston AFB, South Carolina 29404, United States
- Points of contact
-
- Daniel Teeter daniel.teeter@us.af.mil (843) 963-7744
- Taylor McDaniel taylor.mcdaniel.1@us.af.mil (843) 963-4491
Notice details come from SAM.gov. Updated .
About this opportunity
Joint Base Charleston's 628th Civil Engineering Squadron is seeking commercial contractor supplies to provide a Vertical Discharge Cooling Tower for Building 469 located at Joint Base Charleston Air Base in South Carolina. The Department of the Air Force Air Mobility Command issued this sources sought notice on January 27, 2026, with responses due by January 29, 2026. The procurement requires an open circuit induced-draft vertical discharge cooling tower, specified as EVAPCO Model AT 29-4K21 or an equivalent product, that must include a 5-year parts and labor warranty along with factory start-up and commissioning services performed by a manufacturer representative. The government will evaluate contractor responses to assess the market capability and may use this feedback to refine the Salient Characteristics specifications prior to issuing a formal solicitation. Respondents must submit information electronically to daniel.teeter@us.af.mil, though this sources sought notice does not constitute a binding commitment from the government, and no costs associated with responding will be reimbursed.
This procurement is designated as a Total Small Business set-aside under NAICS Code 333415 (Air-Conditioning and Warm Air Heating Equipment Manufacturing), with a size standard of 1,250 employees. The cooling tower specification includes detailed technical parameters: design conditions of 95°F dry bulb and 80.7°F wet bulb, water inlet and outlet temperatures of 95°F and 85°F respectively, and a water flow capacity of 1,418.1 gallons per minute. The equipment must feature 316 stainless steel construction for the cold water basin and upper components, a 5-probe electronic water level control package, stainless steel basin heaters, a fan vibration switch, sump sweeper piping with high flow eductors, fan motor shaft grounding rings, and VFD service-rated fan motors, with a maximum footprint of 9 feet by 23 feet. No specific award value or budget range is disclosed in this sources sought notice, and no incumbent contractors are identified. The government has not committed to issuing a formal solicitation and reserves the right to proceed or modify the requirement based on responses received.
Notice text
SOURCES SOUGHT: THIS IS NOT A REQUEST FOR PROPOSAL BUT A REQUEST FOR INFORMATION FOR PLANNING PURPOSES ONLY! It does not constitute a solicitation and/or quote and is not to be construed as a commitment by the Government.
Joint Base Charleston anticipates this requirement to remain a total small business set-aside. The North American Industry Classification Systems {NAICS) Code proposed 333415. The size standard for NAICS is 1,250 Employees.
Purpose:
The purpose of this sources sought is to seek out commercial contractor supplies to provide a Vertical Discharge Cooling Tower located at Bldg 469 on Joint Base Charleston (JB CHS) - Air Base (AB), SC 29404-5021 for the 628th Civil Engineering Squadron (CES).
Request:
The contractor is responsible for providing an open circuit induced-draft vertical discharge cooling tower, EVAPCO Model AT 29-4K21 or equal. The contractor shall also include a 5 year parts/labor warranty, and factory start-up and commissioning from a manufacturer representative. Attached is a copy of the Salient Characteristics.
As stipulated in FAR 15.201, responses to this notice are not considered offers and cannot be accepted by the Government to form a binding contract. No solicitation exists; therefore, do not request a copy of the solicitation. The decision to solicit a contract shall be solely within the Government's discretion.
Any information submitted by respondents to this sources sought is voluntary. This sources sought notice is not to be construed as a commitment by the Government, nor will the Government reimburse any costs associated with the submission of information in response to this notice. Respondents will not be individually notified of the results of any government assessments. The Government's evaluation of the contractor's responses will factor into any necessary alterations to the Salient Characteristics.
Responses should be submitted electronically to the following e-mail address:
daniel.teeter@us.af.mil
RESPONSES ARE DUE NO LATER THAN 29 January 2026, at 4:00 PM EST.
Attachments
| File | Type | Posted |
|---|---|---|
| FY26 HVAC B469 Cooling Tower Salient Characteristics.pdf |
Notice history