H356-- Chimney Stack Inspection and Testing Grand Junction CO. VAMC

Closed Pre-Solicitation Posted

Solicitation number
36C25926Q0583
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
332313 Plate Work Manufacturing
Place of performance
Department Of Veterans Affairs Grand Junction Vamc Co 81501

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Integrated Service Network 19 is conducting market research to identify contractors capable of performing Class II inspection and non-destructive testing of a reinforced concrete chimney stack at the Grand Junction VA Medical Center, with responses due July 8, 2026. This procurement is set aside for Service-Disabled Veteran-Owned Small Businesses.

Work is performed at 2121 North Avenue, Grand Junction, Colorado 81501. The requirement comprises three contract line items: site survey to determine process and equipment, Class II inspection and non-destructive testing using Schmidt Hammer rebound testing, and crane rental contingency. Deliverables include a detailed process and schedule, 360-degree chimney sketches identifying test locations, photographs of defects, and a comprehensive written report within 30 business days documenting all deficiencies, test results, observations, and recommendations.

Contractors must demonstrate qualifications including a registered Professional Engineer with chimney inspection experience, Level II NDT certification per ASNT standards, and Level II rope access training per SPRAT requirements. The contract is anticipated as firm fixed-price.

Responses must include company information, business size certifications, pricing structure availability, Buy American Act compliance documentation, and for small businesses, subcontracting limitations and the nonmanufacturer rule questionnaire. Responses are limited to eight pages. The contracting officer is Kenneth Finchum (kenneth.finchum@va.gov, 303-712-5746), located at the Network Contracting Office in Greenwood Village, Colorado 80111. NAICS 332313; PSC H356.

Notice text

Chimney Stack Inspection and Testing Gand Junction CO. VAMC

Files

File Type Posted
VHA Directive 7717 D 2023-06-13.pdf PDF
36C25926Q0583.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
554-27-117 Conduct Concrete and Civil Site Repairs. Aurora, Colorado 80045, United States · NAICS 238110 Veterans Integrated Service Network 19 Service-Disabled Veteran-Owned Small Business
H379-- Facility Hood Cleaning and Inspection VA Northern Arizona Healthcare System 500 N Hwy 89 Prescott AZ 86313 · NAICS 561790 Veterans Integrated Service Network 22 Service-Disabled Veteran-Owned Small Business
Annual Inventory and Inspection of Fire and Smoke Doors Dallas, Texas 75216, United States · NAICS 541350 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business
J012--Fire Suppression Testing Remains the same 32608, United States · NAICS 811310 Veterans Integrated Service Network 8 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity