H356-- Chimney Stack Inspection and Testing Grand Junction CO. VAMC
Closed Pre-Solicitation Posted
- Solicitation number
- 36C25926Q0583
- Agency
-
Veterans Integrated Service Network 19
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 332313 Plate Work Manufacturing
- Place of performance
- Department Of Veterans Affairs Grand Junction Vamc Co 81501
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Integrated Service Network 19 is conducting market research to identify contractors capable of performing Class II inspection and non-destructive testing of a reinforced concrete chimney stack at the Grand Junction VA Medical Center, with responses due July 8, 2026. This procurement is set aside for Service-Disabled Veteran-Owned Small Businesses.
Work is performed at 2121 North Avenue, Grand Junction, Colorado 81501. The requirement comprises three contract line items: site survey to determine process and equipment, Class II inspection and non-destructive testing using Schmidt Hammer rebound testing, and crane rental contingency. Deliverables include a detailed process and schedule, 360-degree chimney sketches identifying test locations, photographs of defects, and a comprehensive written report within 30 business days documenting all deficiencies, test results, observations, and recommendations.
Contractors must demonstrate qualifications including a registered Professional Engineer with chimney inspection experience, Level II NDT certification per ASNT standards, and Level II rope access training per SPRAT requirements. The contract is anticipated as firm fixed-price.
Responses must include company information, business size certifications, pricing structure availability, Buy American Act compliance documentation, and for small businesses, subcontracting limitations and the nonmanufacturer rule questionnaire. Responses are limited to eight pages. The contracting officer is Kenneth Finchum (kenneth.finchum@va.gov, 303-712-5746), located at the Network Contracting Office in Greenwood Village, Colorado 80111. NAICS 332313; PSC H356.
Notice text
Chimney Stack Inspection and Testing Gand Junction CO. VAMC
Files
| File | Type | Posted |
|---|---|---|
| VHA Directive 7717 D 2023-06-13.pdf | ||
| 36C25926Q0583.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 554-27-117 Conduct Concrete and Civil Site Repairs. | Veterans Integrated Service Network 19 | Service-Disabled Veteran-Owned Small Business | |
| H379-- Facility Hood Cleaning and Inspection | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business | |
| Annual Inventory and Inspection of Fire and Smoke Doors | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| J012--Fire Suppression Testing | Veterans Integrated Service Network 8 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities