The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16 solicited boiler plant gas detection testing services at its Biloxi, Mississippi facility, with a solicitation deadline of August 21 and a posted cancellation effective August 28, 2026. The solicitation (36C25626Q1147) has been cancelled due to insufficient available funds; offerors should disregard submissions and have no contractual obligations.
The cancelled procurement required testing of an installed boiler plant gas detection system comprising one GASGARD XL CO Control Panel (MSA Safety, Model A-GASGARDXL: 8-2-0-0), six Killark CO Sensors (Hubbell, Model VA301D2C0-C0), one GasPoint II Gas Transmitter (Honeywell, Model VA301D2C0MB-C0) monitoring carbon monoxide, nitrogen, carbon dioxide, and sulfur dioxide, and one Honeywell Sensepoint XCD Sensor (P/N: SPXCDULNTXFM) monitoring lower explosive limit. The NAICS code was 213112, Support Activities for Oil and Gas Operations; PSC code H266, Equipment and Materials Testing—Instruments and Laboratory Equipment.
Contractor certification requirements included compliance with the Immigration and Nationality Act of 1952, with attestation that no illegal aliens or non-compliant foreign nationals would be employed. Service Contract Act prevailing wage determination No. 2015-5117 (Revision 30) for Pulaski County, Arkansas and surrounding counties applied, with fringe benefits of $5.55 per hour (or $5.09 under Executive Order 13706), mandatory paid leave, and uniform allowances. Offerors were required to provide three past performance references demonstrating relevant experience.
Notice text
2 versions
Update #2 · Latest ·
boiler
Update #1 ·
Boiler Plant Gas Detection Testing
Files
| File | Type | Posted |
|---|---|---|
| 36C25626Q1147 0002.docx | DOCX document | |
| 36C25626Q1147 0001.docx | DOCX document | |
| ATTACHMENT PAST PERFORMACE QUESTIONAIRE.docx | DOCX document | |
| ATTACHMENT CONTRACTOR CERTIFICATION.docx | DOCX document | |
| 36C25626Q1147.docx | DOCX document | |
| Pulaski Co WD 2015-5117 rev 30.txt | TXT text file | |
| ATTACHMENT LIST OF PAST PERFORMANCE REFERENCES.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| H266--Boiler Plant Gas Detection Testing | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| N045--Boiler 3 Oxygen Analyzer and Steam Flow Meter | Veterans Integrated Service Network 7 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities