GeneMapper ID-X

Closed Special Notice Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
W81XWH21R0074
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Dover AFB, Delaware, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This Special Notice was published by the US Army Medical Research Acquisition Activity on behalf of the Defense Health Agency's Armed Forces Medical Examiner System located at Dover Air Force Base. The notice requests a Firm-Fixed Price contract with Life Technologies Corporation for the purchase and delivery of GeneMapper ID-X software upgrades to support forensic DNA analysis at the Armed Forces DNA Identification Laboratory.

The Special Notice provides details for a sole source procurement of three GeneMapper ID-X version 1.6 full software install upgrades and fifty client upgrades. Interested contractors must identify their capabilities to the contact by July 1, 2021 if they believe a competitive procurement is in the government's best interest. The software upgrades are needed to perform STR analysis on DNA sample files from human remains and must meet specified requirements including compatibility with various panels, Windows 10 operation, security patching, and enhanced user interface and data analysis capabilities.

Notice text

This Notice of Intent to sole source by the US Army Medical Research Acquisition Activity (USAMRAA), Fort Detrick, MD acting on behalf of the Defense Health Agency (DHA), Armed Forces Medical Examiner System (AFMES), located at Dover Air Force Base requests a Firm-Fixed Price (FFP) contract with Life Technologies Corporation for the purchase and delivery, of three version 1.6 GeneMapper ID-X software full install upgrades and Fifty version 1.6 GeneMapper ID-X client upgrades.

The GeneMapper ID-X version 1.6 software STR analysis software is needed to perform data analysis on short tandem repeat 3500XL Genetic Analyzer data files from human remains process at the Armed Forces DNA Identification Laboratory and shall meet the following characteristics:

Specifications:

  • Shall support data transfer to probabilistic genotyping software with streamlined data export.
  • Shall be compatible with 3500 Data Collection Software v4.
  • Shall provide CODIS compatibility, with CODIS 8, CMF3.2, R.16, and CMF3.3 formats.
  • Shall provide off-scale data recovery with higher first-pass success rate for database samples.
  • Shall provide an improved usability and functionality to the user interface, including sample sorting, editing and deleting of alleles, reporting, and printing.
  • Shall provide updated panel manager to accommodate advancements in recent STR chemistries.
  • Shall be able to analyze 3500 Genetic Analyzer sample files generated from PowerPlex Fusion, AmpFlSTR Globalfiler, Minifiler, and Yfiler.
  • Shall be Windows 10 compatible
  • Shall provide quarterly Oracle security patches for the software.
  • Shall have following Enhanced Command Line Interface Functionality:
  • Process multiple commands under the same login
  • Export and import the database
  • Move sample to a new project
  • Export the information in the sample info tab
  • Generate a PDF using the sample file name
  • Print PDF in landscape or portrait orientation
  • Print PDF with page size of A3, A4, A5, legal or letter
  • Shall have the following Enhanced User Interface
    • Select multiple peaks and assign artifact label
    • Normalization in Analysis Method set to “Off” as Default
    • Retain zoom in plot view on Y axis after scrolling
    • Project list is sorted based on date created as a default.
    • Analysis Method and Size Standard drop-down menus sorted alphabetically
    • Use of arrow key to go to the next sample within a sample plot view
    • New sorting option in genotype table to sort by marker name only
    • 3500 Capillary lot information updated in Sample Info view
    • Ability to enter stutter distance greater than 8.5
    • Added confirmation step before deleting an allele
    • Option to display size standard normalization factor from Data Collection in the Samples table and include in report
    • Export Genotypes table with stutter alleles
    • Partial Locus Indicator (PLI)
  • Shall have the ability to have a login drop down that will show active users,
  • Shall have ability to dismiss “Reason for change” box using keyboard commands
  • Shall have ability to purge audit records according to specified time periods
  • Shall have an enhance peak detection algorithm for addressing low level peaks adjacent to high level peaks
  • Shall have enhanced profile comparison tool functionality
  • Shall have enhance print capabilities to print on paper of different sizes with landscape orientation, print the label edit viewer table from the plot view, ability to add custom labels and printing of quality values from the plot view.

The North American Industry Classification System (NAICS) for this requirement is 335990 and PSC 6160.

This Special Notice of Intent is not a request for competitive quotes. Information received in response to this notice will be considered solely for the purpose of determining whether a competitive procurement is in the best interest of the Government.

All questions and responses concerning this notice shall be emailed to Brian Miller at brian.d.miller1.civ@mail.mil, subject W81XWH21R0066.

Interested concerns must identify their capability in writing to the above email address no later than 3:00 PM ET Local, 1 July 2021.

Notice history

Similar open opportunities

Opportunity Agency Set-aside Responses due
Notice of Intent DNA Synthesizer Frederick, Maryland 21702, United States · NAICS 334516 — No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity