GEN-620 120V-2000W-7. 5kW-60Hz-16yr-TSW Geneforce Emergency Power System
Closed Pre-Solicitation Posted
- Solicitation number
- PANHCA-25-P-0000-009017
- Agency
-
Medical Command
Department of the Army, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238290 Other Building Equipment Contractors
- Place of performance
- Washington 98431, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Medical Command is seeking to procure a specialized Geneforce Emergency Power System (GEN-620) designed for critical medical facility backup power needs. The generator is specifically intended to support two refrigerators and two -20C freezers with a robust power management system featuring 2000 Watts of continuous output and 4000 Watts of surge power capability. Key technical requirements include automatic power switching in less than one second, a compact mobile unit with dimensions no larger than 35" x 18" x 24", and multiple voltage outputs including 120V, 110V, and 108V. The pre-solicitation notice indicates the system must be gas/diesel free, UL listed for safety, and include specific electrical receptacle configurations. The solicitation is set to be open from May 7, 2025, to May 18, 2025, with potential contractors expected to meet comprehensive technical specifications and power management standards.
The opportunity is designated as a Total Small Business set-aside, targeting contractors within the NAICS category 238290 (Other Building Equipment Contractors) and PSC category 6150 (Miscellaneous Electric Power And Distribution Equipment). The generator system offers an impressive 12-16 year battery life expectancy with rechargeable batteries lasting up to five years and includes a two-year warranty. While specific award value ranges are not explicitly stated, the technical complexity and specialized medical application suggest a potentially significant contract opportunity. The system's advanced features include a solar charge controller, multi-stage charging capabilities, voltage regulation, and comprehensive temperature and electrical protection mechanisms. Interested small businesses must carefully review the detailed technical specifications and be prepared to demonstrate compliance with the Army Medical Command's stringent requirements for emergency power infrastructure.
Notice text
See Attachment for Description
Files
| File | Type | Posted |
|---|---|---|
| Generator Description.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Sources Sought – FY27 Temporary Backup Generator and Transformer Lease and Sustainment – Winn Army Community Hospital, Fort Stewart, Georgia | Mission and Installation Contracting Command | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity