Gas fired humidifier

Closed Solicitation Posted

Solicitation number
W51AA125Q0012
Agency
Department of the Army Department of Defense
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
PSC
N041 Installation Of Equipment- Refrigeration, Air Conditioning, And Air Circulating Equipment
Place of performance
Tobyhanna, Pennsylvania 18466, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army is soliciting proposals for a GS 00-CS Nortec Single Zone Gas Fired Humidifier for Tobyhanna Army Depot. The solicitation (W51AA125Q0012) requires removing and replacing an existing NORTEC GSTC-300NDV gas-fired humidifier in room 1A-278, with a new like-in-kind humidifier capable of 300 lb/hr capacity. Contractors must provide all labor, materials, equipment, and supervision for installation, including factory-authorized startup and commissioning. The solicitation requires contractors to submit equipment submittals and shop drawings within 10 days of award and provide startup and commissioning reports within 30 days of installation completion. Responses are due by December 16, 2024, at 12:00 PM, and the contract will be awarded under NAICS code 333415 with a size standard of 1,250 employees.

The solicitation is an unrestricted procurement with no specific set-aside designations. The place of performance is located at Tobyhanna Army Depot in Tobyhanna, Pennsylvania. Payment will be processed through Wide Area Workflow (WAWF) with HQ0303 as the pay office. The project involves comprehensive installation requirements, including electrical and control connections, integration with the existing Modular Air Handling Unit (MAHU01), and compliance with environmental and safety regulations. Contractors must ensure proper modifications to existing ductwork and piping systems, install water filters and necessary switches, and complete a comprehensive installation that meets all technical specifications outlined in the detailed project documentation.

Notice text

GS 00-CS NORTEC SINGLE ZONE, GAS FIRED HUMIDIFIER WITH STAND. INCLUDES WATER FILTERS, SWITCHES, DUCT MODIFICATIONS AND PIPE MODIFICATIONS INCLUDING FACTORY AUTHORIZED CHECK, TEST START-UP & INSTALLATION. 

SEE STATEMENT OF WORK AND ATTACHED SPECS.
 

Attachments

Files attached to this notice, newest first
File Type Posted
SOLICITATION W51AA125Q0012.pdf PDF
Nortec-1.pdf PDF
Nortec-2.pdf PDF
Nortec-3.pdf PDF
Nortec-10.pdf PDF
1A-4-292.pdf PDF
Nortec-9.pdf PDF
Nortec-5.pdf PDF
Nortec-4.pdf PDF
Nortec-8.pdf PDF
1A-4-297.pdf PDF
Nortec-6.pdf PDF
Nortec-7.pdf PDF
1A-5-416.pdf PDF
Show all 14

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity