FY26 NASA ames research center survey
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- W912DY26RA061
- Agency
-
Engineering Support Center Huntsville
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 541330 Engineering Services
- PSC
- P400 Salvage- Demolition Of Buildings
- Place of performance
- 64 Facilities at Moffett Blvd, Mountain View, CA 94035 94035
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The US Army Corps of Engineers, Engineering Support Center Huntsville, is soliciting pre-demolition environmental surveys at NASA Ames Research Center in San Francisco, with proposals due June 1 and questions due May 25.
Place of performance is Moffett Boulevard, Mountain View, California. The contract requires environmental sampling and analysis of designated facility structures to quantify asbestos-containing materials (ACM), other regulated materials (ORM), lead-based paint (LBP), and polychlorinated biphenyls (PCBs) in paint, as well as waste stream analysis for RCRA 8 metals. The contractor must complete laboratory testing and analysis within workdays specified in the Performance Work Statement following field sampling completion. All sampling, recommendations, and follow-on actions must comply with federal, state, and local regulations. The deliverable is an individual Pre-Demolition Assessment Report for the installation.
The NAICS code is 541330, Engineering Services, and the PSC code is P400, Salvage—Demolition of Buildings. No set-aside applies. The solicitation operates on Central Standard Time.
Notice text
NASA has tasked the US Army Corps of Engineers, Engineering andSupport Center, Huntsville, to initiate a Facility Reduction requirement at the AMES research center inSan Francisco, CA. Buildings are considered excess and will be demolished. The purpose of thiscontract is to procure Pre-demolition surveys according to the requirements set forth in thisPerformance Work Statement (PWS).The objective is to plan and complete the environmental sampling facilities as identified in the PWS.The objective of the Performance Work Statement is to plan and complete the environmentalsampling of facilities at the installation. The structures of concern are listed in Table I of the PWS. Thesampling will determine ACM and ORM materials and complete a Waste Stream Analysis for RCRA 8metals, lead-based paint (LBP) and PCB?s-in-paint for those parts of the structure currently identifiedas potentially having any painted components. Following sampling, the Contractor shall be able tocompletely quantify the environmental contamination present and the methods required to removeand dispose of contamination in a safe manner. All sampling shall be planned and performed inaccordance with Federal, State, and local regulations for the installation. All recommendations forfollow-on actions shall also be in accordance with Federal, State, and local regulations. Laboratorytesting and analysis shall be completed within the workdays identified in table two following therespective site sampling field activity completion. The results of the site investigation and samplingeffort will be provided in an individual Pre-Demolition Assessment Report for the installationRefer to the PWS and attached documents for requirement specifics.*Projnet Questions due by 25 May 2026.**Note the solcitation is in CST - Central Standard Time*
Notice history
| Notice | Type | Posted |
|---|---|---|
| FY26 NASA ames research center survey | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Virginia Department of Environmental Quality Regulatory Oversight for Wallops Flight Facility | Shared Services Center | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity