About this opportunity

The Department of the Army Corps of Engineers Engineering District Omaha seeks tank inspection services at Joint Base Lewis-McChord, Washington, with proposals due May 21, 2026. The procurement is a Total Small Business set-aside.

Work includes three API 653 tank inspections (two internal inspections with wiper seal replacement on facilities J12184 and J12187, and one external inspection on facility J42003) and fourteen STI inspections, all performed in accordance with applicable federal, state, and local laws, standards, and regulations. Place of performance is Joint Base Lewis-McChord, WA. The NAICS code is 541990, All Other Professional, Scientific, and Technical Services; the PSC code is Z1GC, Maintenance of Fuel Storage Buildings. Addition 0001 added a question set, and Change 0002 added Attachment Js to the solicitation.

Notice text

3 versions

Update #3 · Latest ·

Conduct 3ea API 653 inspections (2 internal with wiper seal replacement on FAC J12184 and J12187) and (1 external inspection on FAC J42003); conduct 14ea STI inspections at Joint Base Lewis McChord, WA, in accordance with all laws standards, federal regulations, as well as any state and local regulations and guidelines. *****Addition 0001 Question Set Addition***** Change 0002 Addition of Attachment Js.

Update #2 ·

Conduct 3ea API 653 inspections (2 internal with wiper seal replacement on FAC J12184 and J12187) and (1 external inspection on FAC J42003); conduct 14ea STI inspections at Joint Base Lewis McChord, WA, in accordance with all laws standards, federal regulations, as well as any state and local regulations and guidelines. *****Addition 0001 Question Set Addition*****

Update #1 ·

Conduct 3ea API 653 inspections (2 internal with wiper seal replacement on FAC J12184 and J12187) and (1 external inspection on FAC J42003); conduct 14ea STI inspections at Joint Base Lewis McChord, WA, in accordance with all laws standards, federal regulations, as well as any state and local regulations and guidelines.

Similar open opportunities

Opportunity Agency Set-aside Responses due
Vandenberg SFB Tank Inspection Vandenberg SFB, CA 93437 · NAICS 541990 ENDIST Omaha Service-Disabled Veteran-Owned Small Business
Fort Campbell, KY - API 653 External Tank Inspection 42223 · NAICS 541990 ENDIST Omaha Service-Disabled Veteran-Owned Small Business
J091--Aboveground Fuel Tank Inspection Services - Kansas City VAMC Department of Veterans Affairs Kansas City VA Medical Center Kansas City MO 64128, United States · NAICS 562910 Veterans Integrated Service Network 15 No set-aside
Fort Leavenworth Underground Fuel Tank Testing and Repair Services Fort Leavenworth, Kansas 66027, United States · NAICS 541620 MICC Fort Eustis Total Small Business
Joint base lewis mcchord multi domain task force buildings 3223-3224, washington Joint Base Lewis McChord, Washington 98433 · NAICS 236220 ENDIST Seattle Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors