Fuel Tank Repair and Maintenance -Seymour Johnson AFB, NC
Closed Pre-Solicitation Posted
- Solicitation number
- W9128F26SM007
- Agency
-
ENDIST Omaha
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 237120 Oil and Gas Pipeline and Related Structures Construction
- Place of performance
- North Carolina 27531, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers (USACE)-Omaha District is conducting a Sources Sought Notice to identify capable contractors for repairs and maintenance of two vertical aboveground storage tanks (Tank 1 and Tank 2) at Seymour Johnson Air Force Base in North Carolina. All work must comply with American Petroleum Institute (API) 653 standards and the DoD Aboveground Storage Tank Standard AW 78-24-27, with scope items including tank bottom perimeter replacement, hydrostatic testing, piping system repairs, thermal relief line replacement, tank level arm replacement, stair repairs, internal ladder replacement, inspection hatch repairs, chime sealant replacement, containment area repairs, wiper seal replacement, and final API 653 inspection reporting. Responses must be submitted from prime construction contractors with a minimum bonding capacity of $5 million per single job by 1200 Mountain Time on February 20, 2026, sent to Contract Specialist Phillip.L.Wickham@usace.army.mil and Contracting Officer Jessica.L.Beckman@usace.army.mil. This is a planning notice only and does not constitute a binding solicitation, guarantee of future award, or request for proposals, though it will inform the government's procurement planning for upcoming solicitations. Interested firms must submit a narrative response not exceeding 5 pages that includes company details, CAGE Code, UEI, small business classification status, SAM registration confirmation, relevant prior experience, business size, details of similar projects, construction timeline projections, project references with contact information, and specific bonding capacity documentation.
There is no set-aside designation for this opportunity, and no incumbent or current contractor is identified in the notice. The estimated project cost ranges from $5 million to $10 million, with a performance period of 450 calendar days from the notice to proceed. The applicable NAICS code is 237120 (Oil and Gas Pipeline and Related Structures Construction), and the PSC category is Y1GC (Construction of Fuel Storage Buildings). This is a planning notice for informational and market research purposes only; prior federal government contract work is not a prerequisite for submitting a response, and all costs associated with responding are the responsibility of the interested party. The government will not pay for any information or administrative costs incurred in connection with this Sources Sought submission.
Notice text
Sources Sought Response Form
Sources Sought Notice # W9128F26SM007
PURPOSE: By way of this Sources Sought Notice, the USACE-Omaha District intends to determine the extent of capable small business or other than small business firms that are engaged in providing the requirement described hereunder. The responses to this notice will be used for planning purposes for upcoming procurements. Therefore, this notice does not constitute a Request for Proposal (RFP), Quotation or Bid; it does not guarantee the future issue of an RFQ/RFP/IFB; nor does it commit the government to contract for any supply, service, or construction. There is no solicitation currently available.
Further, this Agency will not accept unsolicited proposals. Respondents are advised that this Agency will not pay for any information or administrative cost incurred in response to this Notice. All costs associated with responding to this Notice will be solely at the responding party's expense. At this time, proprietary information is not being requested, and respondents shall refrain from providing proprietary information in response to this Sources Sought Notice.
PROJECT DESCRIPTION: This project includes repairs and maintenance of two vertical aboveground storage tanks –Facility 10241 (Tank 1) and Facility 10242 (Tank 2), located at Seymour Johnson, AFB, NC. :
The repair and maintenance items below shall be performed to comply with American Petroleum Institute (API) 653 and all applicable design criteria and standards provided in paragraph Design Criteria and Reference Publications below. The DoD Aboveground Storage Tank (AST) Standard AW 78-24-27 shall govern where it conflicts with API 650 or API 653. All Repairs shall be conducted in accordance with the most current codes and standards applicable with each repair. Contractor is required to obtain all necessary permits required for this project and review the State regulations concerning repair of AST’s. Complete the API 653 Repairs based on the design references and criteria provided herein. This includes, but is not limited to, design, construction, all necessary labor, equipment, and materials for satisfactory operation of the
project.
Work to include: replace the perimeter of the tank bottom, perform hydrostatic test, repair issue piping, repair low suction piping, replace thermal relief lines, remove mechanical tape gauge, replace tank level arms, repair tank stairs, repair water draw -off system, provide stilling wells, repair floating pan, replace internal ladder, repair inspection hatches, replace tank chime sealant, repair containment area, repair rank grounding, provide scaffold supports, replace wiper seals, repair cathodic protection, provide tank data plate, repair tank coatings, provide tank strapping chart, and provide final API 653 inspection report.
Estimated Project Solicitation Issue date: TBD
Small Businesses are reminded under FAR 52.219-14© (1), Limitations on Subcontracting Services. At least 50 percent of the cost of contract performance incurred for personnel shall be expended for employees of the concern. Prior Government contract work is not required for submitting a response to this Sources Sought synopsis.
(For Construction): Project Period of Performance: 450calendar days from construction NTP.
RESPONSES: Please respond to all information requested in this notice not later than 1200 Mountain Time, Friday 20 February 2026 Please include the Sources Sought Notice Identification Number (W9128F26SM007) in the subject line of the email submission with Attention to:
Contract Specialist Phillip.L.Wickham@usace.army.mil
Contracting Officer Jessica.L.Beckman@usace.army.mil
REQUIRED INFORMATION TO BE SUBMITTED IN RESPONSE TO THIS NOTICE:
- Company Name, address, phone number, point of contract, email, web address:
- CAGE Code and Unique Entity Identifier (UEI):
- North American Industry Classification System Code (NAICS):
- State whether your firm is classified by the Small Business Administration as any of the following:
Small Business
Small Disadvantaged Business
Service-Disabled Veteran Owned Small Business (SDVOSB)
Section 8(a)
Women Owned Small Business (WOSB)
HUBZone
None of the above
*If none of the above, are you a large business?
- Is your company currently registered in System for Award Management (SAM)?
- Has your company performed work for the federal government? Has you company performed work for the federal government under a different name or UEI/DUNS #, or as a member of a Joint Venture (JV)? If yes, provide an explanation:
CAPABILITIES AND SUBMISSION REQUIREMENTS:
SUBMISSION DETAILS:
All interested, capable, qualified, and responsive contractors are encouraged to reply to this request.
NAICS code 237120 – Oil and Gas Pipeline Related Structures Construction
Interested PRIME CONTRACTORS ONLY should submit a narrative demonstrating their experience in construction projects of similar nature as described in the Project Description. Responses are requested only from: POTENTIAL PRIME CONSTRUCTION CONTRACTORS WITH COMPANY BONDING CAPABILITY (SINGLE JOB) OF AT LEAST $5 Million Narratives shall be no longer than 5 pages Email responses are required.
Please include the following information in your response/narrative:
•Business size to include any official teaming arrangements as a partnership or joint venture
•Details of similar projects and state whether you were the Prime or Subcontractor
•Start and end dates of construction work
•Project references (including owner with phone number and email address)
•Project cost, term, and complexity of job
•Information on your bonding capability - SPECIFICALLY IDENTIFY CAPACITY OF PERFORMANCE AND PAYMENT BONDS
In accordance with FARS 36.204 the magnitude of this project is expected to range between $5 Million and $10 Million.
COMMENTS:
Provide comments or identify any concerns your company has regarding the planned solicitation. Note that the Government will not be responding to inquiries about the proposed solicitation at this time. Your responses and comments will be used by Government personnel to assess the viability and scope of the proposed solicitation and will be kept in strictest confidence. Telephone inquiries will not be accepted.
Files
| File | Type | Posted |
|---|---|---|
| Sources Sought _SMJ_Tank Repair.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| DESC2103C - Bulk Fuel Storage Tanks Phase II, Yokota Air Base, Japan | ENDIST Japan | No set-aside | |
| Fort Campbell, KY - API 653 External Tank Inspection | ENDIST Omaha | Service-Disabled Veteran-Owned Small Business | |
| Fort Leavenworth Underground Fuel Tank Testing and Repair Services | MICC Fort Eustis | Total Small Business | |
| Vandenberg SFB Tank Inspection | ENDIST Omaha | Service-Disabled Veteran-Owned Small Business | |
| FMC Rochester- Install Above Ground Tanks | Federal Medical Center Rochester | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity