Fuel tank integrity testing

Awarded Intent to Bundle Requirements (DoD-Funded) Posted

Solicitation number
31125PR260000720
Agency
Set-aside
No set-aside

Opportunity facts

Contract number
31125PR260000720

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Coast Guard is conducting a service-disabled veteran-owned small business (SDVOSB) set-aside for external and internal inspections of aboveground fuel tanks and potassium sodium tanks at USCG Base Cape Cod in Bourne, Massachusetts, with award targeted for June 25, 2026.

The contractor must perform external inspections of six tanks in accordance with Steel Tank Institute SP001 standards and internal inspections with wall thickness testing per API 653 on three tanks: one 30,000-gallon JP-8 tank and two 15,000-gallon JP-8 tanks located adjacent to Taxiway Delta. Work spans four years with a staggered inspection schedule: Year 1 covers the 30,000-gallon tank; Year 2 covers the two 15,000-gallon tanks; Year 3 covers two 10,000-gallon gasoline tanks near the Mini Mart; and Year 4 covers the two 5,000-gallon potassium sodium tanks and remaining 5,000-gallon and 6,000-gallon tanks. All inspections must be completed within 45 calendar days of Notice to Proceed.

Deliverables include completed STI SP001 AST records, a detailed condition report documenting observed deterioration, test results, and remaining service life predictions, and repair cost estimates. The contractor must develop a Safety Plan using USACE EM 385 framework, an Environmental Protection Plan addressing storm water, and ensure all personnel pass NCIC background checks. Work hours are 7:00 A.M. to 4:00 P.M., Monday through Friday, excluding Federal Holidays. Solicitation number is 3112SP26000270; contact Jason Williams at 571-608-4843.

Notice text

1.1 SCOPE: The Contractor shall provide all personnel, equipment, tools, materials, supervision, and other items and services necessary to perform external inspections of aboveground fuel tanks, and potassium sodium tanks.  Internal inspections and tank wall thickness measurements shall be included in inspection for three (3) tanks – one (1) 30,000 gallon JP-8 tank, and two (2) 15,000 gallon JP-8 tanks located adjacent to taxiway delta.    Contractor shall provide a detailed report of conditions found to include estimates for repairs. All work located at USCG Base Cape Cod in Bourne, MA 02542.  

1.1.2 REQUIRED WORK: This list should not be considered complete. It represents the general items needed to complete the contract requirements. Base Cape Cod manages six (6) above ground tanks that are greater than or equal to 6,000 gallons, that are used for the storage of fuel products.  Three (3) above ground tanks, used for the storage of gasoline, are located adjacent to Coast Guard Base Cape Cod’s (BCC) Mini Mart.  Two (2) of the tanks adjacent to BCC’s Mini-Mart have a 10,000 gallon capacity the third tank has a 6,000 gallon capacity.  Three (3) above ground tanks, used to store JP-8 (aviation fuel), are located adjacent to Taxiway Delta behind building 3170.  Two (2) of the tanks adjacent to Taxiway Delta have a 15,000 gallon capacity, the third tank has 30,000 gallon capacity. Base Cape Cod also manages two 5,000 gallon potassium sodium tanks located behind building 124. Inspect the tanks in accordance with Steel Tank Institute (STI) SP001 and complete the STI SP001 AST record. Perform wall thickness testing, and internal inspection IAW API 653.  Wall thickness testing, and internal inspection to only be completed on 30,000-gallon tank, and two (2) 15,000-gallon tanks located adjacent to taxiway delta.   Drafting a report on the condition of the tanks including any observed deterioration, the results of tests, and predictions of the expected service life remaining.

1.1.3 TANK INSPECTION SCHEDULE: Work shall be completed over a four (4) year period. Year 1; Inspect 30,000 gallon tank adjacent to taxiway delta Year 2, Inspect two (2) 15,000 gallon tanks adjacent to taxiway delta Year 3, Inspect two (2) 10,000 gallon tank adjacent to CGEX Year 4, Inspect 5,000 gallon tank adjunct to CGEX & (2) 5,000 gallon Potassium Sodium Tanks

SEE SOW FOR FULL DETAILS

Awarded contract 31125PR260000720 to unknown vendor for unknown amount on 2026-06-25.

Files

File Type Posted
SF1449-21 SOLICITATION.pdf PDF
Tank Integrity Testing Statement of Work.doc DOC document
DEI CLAUSE FOR SOLICITATIONS.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Vandenberg SFB Tank Inspection Vandenberg SFB, CA 93437 · NAICS 541990 ENDIST Omaha Service-Disabled Veteran-Owned Small Business
Maintenance and Repairs of Aboveground Storage Tanks (AST) and Underground Storage Tanks (UST) at the Naval Station Newport; Naval Undersea Warfare Center, Newport Rhode Island and Other Areas of Responsibility (AOR) Newport, Rhode Island 02841, United States Naval Facilities Engineering Command No set-aside
Drydock Repairs USCGC HATCHET (WLIC-75309) NAICS 33661 — Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity