Freeze Dry System- Brand Name or Equal -Brand Name and Equal (BNE)

Closed Solicitation Posted

Solicitation number
FDA-RFQ-CBER-2026-135296
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Silver Spring, Maryland, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The FDA Office of Acquisition and Grant Services seeks one benchtop freeze dryer (lyophilizer) system with related equipment and services, with quotations due September 28, 2026 at 12:00 PM Eastern Time and written questions due September 25, 2026 at 4:00 PM EDT. This is an unrestricted, full and open competition structured as a Brand Name or Equal procurement on a Lowest Price Technically Acceptable basis without discussion.

Place of performance is Silver Spring, Maryland. The system must achieve a collector temperature of -84°C or colder, approximately 2.5 liters ice capacity, a 12-port drying chamber for simultaneous multi-sample processing, and operate on 230V/50-60 Hz electrical configuration. Condenser coils must be stainless steel or PTFE-coated. Initial flask sets (150 mL and 300 mL), tubing, clamps, and adapters are included. A compatible vacuum pump is already available and should not be quoted.

The procurement comprises seven contract line items: the base unit, 12-port drying chamber manifold, initial flask sets, tubing/clamps/adapters, shipping and delivery to the FDA facility, on-site installation and operational verification, and a standard one-year manufacturer warranty covering parts and labor. Delivery is required within 60 days of award. Pricing shall be firm fixed and inclusive of all shipping and applicable fees with no additional charges accepted post-award. The NAICS code is 334516, Analytical Laboratory Instrument Manufacturing, with a small business size standard of 1,000 employees or fewer. The PSC code is 6640, Laboratory Equipment and Supplies.

Notice text

Notice of Combined Synopsis/Solicitation. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation; quotes are being requested, and a separate written solicitation will not be issued. The NAICS for this requirement is: 334516. The government is not obligated to make an award. The Government is not obligated to pay costs incurred by the Contractor during quote preparation and quote submission.

Background: The U.S. Food and Drug Administration (FDA) laboratory requires a benchtop freeze dryer (lyophilizer) system to support ongoing scientific research and sample preservation activities. Lyophilization (freeze-drying) is a critical process used to preserve the stability and integrity of biological samples, pharmaceuticals, and other moisture-sensitive materials by removing water content through sublimation under vacuum. The required system must achieve a collector temperature of -84 °C or colder to accommodate samples with lower freezing points, including those containing organic solvents. The system must be configured for 230V/50-60 Hz operation consistent with the FDA laboratory's electrical infrastructure.

Minimum Performance Requirements/Salient Characteristics:

This is a Brand Name or Equal requirement. Products other than the aforementioned are acceptable but shall meet all the salient characteristics contained in the Minimum Technical Requirements below:

All of the following system requirements are minimum requirements. Equivalent requirements that differ from these minimum requirements shall be justified by the proposing vendor and evaluated prior to purchase:

General

The contractor shall provide One (1) benchtop freeze dryer (lyophilizer) system meeting the following minimum technical specifications, including all required accessories, tubing, clamps, adapters, and standard warranty necessary for full system assembly and operation:

•           Collector Temperature: -84 °C or colder (to accommodate samples containing organic solvents such as acetonitrile or methanol)

•           Collector Capacity: Approximately 2.5 liters of ice capacity before defrost cycle

•           Condenser Type: Stainless steel or PTFE-coated coils (corrosion-resistant construction)

•           Drying Chamber: 12-port drying chamber or manifold for simultaneous multi-sample processing

•           Accessories: Initial set of flasks (150 mL and 300 mL), all necessary tubing, clamps, and adapters required for full system assembly

•           Electrical: 230V, 50/60 Hz configuration

Place of Performance:
The prospective vendor should provide insured shipping of equipment to:

U.S. Food and Drug Administration,
Attn: Kyung Sung
10903 New Hampshire Ave, Building 52/72. Room 3248
Silver Spring, MD 20993

Period of Performance:

Performance begins on the date of formal government acceptance and continues through the end of the manufacturer's warranty period.
 

Quotes are due by email on or before September 28 2026, by 12:00 P.M. (Eastern Standard Time) and should be sent to brandon.rafus@fda.hhs.gov.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
REFRIGERATOR-FREEZER, and 6 more items Medical Supply Chain Total Small Business
FREEZER,MECHANICAL,FO and 1 more item Subsistence No set-aside
Freezer,mechanical,FO Subsistence No set-aside
CSS - NVision POLARIS (Brand Name or Equal) NAICS 334516 Office of Logisitics and Acquisition Operations No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors