About this opportunity

The Department of the Navy's Naval Sea Systems Command seeks Phase I SBIR proposals for a fire-resistant joiner bulkhead material or system for ships, with responses due November 25, 2026. The set-aside is Total Small Business, so the solicitation carries no restrictive eligibility constraint.

The topic, DoD SBIR DON27BZ01-NV002, asks for a material or system that increases the fire resistance of shipboard joiner bulkheads and contains compartment-level fires so damage control teams can extinguish them before they spread. Proposals must meet Navy requirements for weight, fit, cost, fire, smoke, and toxicity. The source identifies weight as the first technical challenge: any bulkhead solution must not add significant weight, because joiner bulkheads are numerous onboard and added weight would impair ship performance. Focus areas are Advanced Materials and Sustainment & Logistics. Keywords include intumescent coatings, bio-composites, bulkhead fire containment, and high-performance fibers.

Compliance markers are CMMC Level 2 (Self) and ITAR: No. The notice is coded NAICS 541715 (Research and Development in the Physical, Engineering, and Life Sciences, except Nanotechnology and Biotechnology) and PSC AC12 (National Defense R&D Services).

Notice text

DoD SBIR topic DON27BZ01-NV002

Component: NAVY

Command: NAVSEA

Phase: SBIR Program Phase I Action

Technology Areas: None

Focus Areas: Advanced Materials; Sustainment & Logistics

Keywords: Fire Safety; Intumescent Coatings; Bio-Composites; Bulkhead Fire Containment; Fire Protection; High-performance Fibers

ITAR: No

CMMC: Level 2 (Self)

Objective:

Develop a material/system to increase the fire-resistance of joiner bulkheads on ships and compartment-level fire containment while meeting Navy requirements for weight, fit, cost, fire, smoke and toxicity.

Description:

Fire represents a grave hazard to Navy vessels. Recent fire events have propagated through joiner bulkheads and resulted in significant fire damage, which poses a substantial threat to personnel and equipment. Uncontrolled fires can propagate throughout a ship and cause extensive damage to machinery, equipment, and ship compartments; additionally, fires represent an extreme risk to ship personnel. The Navy has made numerous improvements to make ships more fire-resistant but is seeking improvement for containment of compartment-level fire events seen in recent and historical ship fires (i.e., USS OSCAR AUSTIN, USS CONYNGHAM, USS STARK, and the cruise ship Star Princess). More fire-resistant joiner bulkheads would allow damage control teams to contain and extinguish fires more easily before they could grow to threaten the ship. Innovation is needed to meet Navy goals with regard to weight, cost, fit, and performance.

The Navy seeks an improved fire-resistant joiner bulkhead that would reduce the damage ships sustain during fires, as well as improve safety for the crew.

Development of a fire-resistant joiner bulkhead faces several technical challenges. First, any fire-resistant joiner bulkhead must not have a significant weight increase. Given the quantity of joiner bulkheads onboard ships, any weight increase could add significant weight to the ships, which will impair and degrade ship performance. Second, the improved joiner bulkheads must not excessively exceed the width of current joiner bulkheads. Destroyers have confined spaces and for the comfort and operational capability of the crew, any new joiner bulkhead cannot greatly exceed the dimensions of the existing panels. Third, any fire-resistant joiner bulkhead must be a cost-effective solution for the Navy. In particular, the fire-resistant joiner bulkhead must not substantially increase the costs to install at the shipyard. The reason for this concern is that joiner bulkheads sometimes require modification at the shipyards to fit the exact dimensions of the ship. Any solution that requires expensive edge treating or would otherwise be cost-prohibitive to modify at the shipyards will not be considered. Lastly, the improved joiner bulkhead must meet or exceed the requirements to be certified for shock and fire performance as AN-30 class per MIL-STD-3020 and pass Navy Fire, Smoke, Toxicity (FST) testing per MIL-STD-1623. This is a vital requirement to demonstrate that any new material in the joiner bulkhead will not release dangerous particulates as it burns or fails if there is an impact.

Research into fire-resistant materials has revealed several technology advances in the areas of intumescent coatings, coatings that incorporate nanomaterials to aid in thermal regulation, or advanced high-performance fibers; however, there is no current commercial solution available. The Navy is also open to bio-composites, bio-polymers, or other materials that have the potential to provide superior fire-resistance with reduced toxicity as compared to many commercially available products.

Phase I:

Develop a concept for a fire-resistant joiner bulkhead that meets the requirements above. Demonstrate the feasibility of the concept in meeting the Navy needs prescribed above and establish that the concept can be developed into a useful product for the Navy. Establish feasibility of a new fire-resistant material/system via small-scale testing. If the Phase I Option is exercised, include the initial design specifications and a capabilities description to build a prototype solution in Phase II.

Phase II:

Develop and deliver a prototype fire-resistant joiner bulkhead for evaluation. (Note: The prototype will be evaluated to determine capability in meeting the performance goals defined in the Phase II SOW.) Demonstrate product performance through prototype evaluation, modeling, and demonstration over the required range of parameters as defined by the Navy. Participate in an extended evaluation in a land-based test environment to refine the prototype into a design that will meet Navy requirements. Prepare a Phase II manufacturing and development plan, including drawings of connection details, to transition the improved fire-resistant joiner bulkhead to Navy use.

Phase III:

Support the Navy in transitioning the fire-resistant joiner bulkhead to Navy use. Develop installation and maintenance manuals for the improved fire-resistant joiner bulkhead to support transition to the Fleet.

Many potential commercial applications for improved fire-resistant joiner bulkheads exist; examples include commercial shipping, construction, aerospace, and automotive industries.