Fire Protection for Robins North
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- FA857124Q0019
- Agency
- Air Force Sustainment Center Air Force Materiel Command, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Macon, Georgia 31216, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks proposals to provide fire protection systems for two sandblasting booths at Robins North Air Force Base in Georgia. The Air Force Sustainment Center is procuring the installation of new wet pipe sprinkler systems and ceiling horn/strobes. Proposals are due by the date specified, and the contract will have a one year base period of performance from January 2024 to January 2025. Pricing must be fixed and firm. Proposals will be evaluated for compliance with specifications and terms defined in the purchase description.
There are no set-aside designations specified. The work involves installation of fire protection systems under NAICS 238210 and PSC R499. The place of performance will be at Robins North Air Force Base in Macon, Georgia. The solicitation does not name any incumbent or current contractors. The contract type will be fixed unit price for the one year base period and four one-year options, but the solicitation does not specify potential award values. Safety and reporting requirements are defined in attached contract data requirement lists.
Notice text
The Contractor shall provide all materials, parts, travel, tools, installation and labor necessary in regard to fire
protection systems for the sanding booths at Robins North to the Commodities Maintenance Group (CMXG) at
Robins Air Force Base (AFB), Georgia.
The contractor shall install fire protection systems comprising of both fire suppression and fire alarms in
accordance with the following criteria: Two (2) new wet pipe sprinkler with low drainage point for existing
sandblasting booth at Robins North Sprinkler styles will be Chrome recessed Pendants 155 deg. QR 5.6 KFactor
OR Horizontal Sidewall sprinkler 155 Deg. QR 5.6 or 8.0 K-Factor Two (2) ceiling Horn/Strobes will be added at the opening of the sanding booths and tie into the existing NAC circuit
Attachments
| File | Type | Posted |
|---|---|---|
| IMG_0612.jpg | JPG image | |
| IMG_0615.jpg | JPG image | |
| IMG_0621.jpg | JPG image | |
| IMG_0619.jpg | JPG image | |
| IMG_0614.jpg | JPG image | |
| IMG_0620.jpg | JPG image | |
| IMG_0617.jpg | JPG image | |
| IMG_0611.jpg | JPG image | |
| IMG_0613.jpg | JPG image | |
| IMG_0616.jpg | JPG image | |
| IMG_0618.jpg | JPG image | |
| 73956 Appendix C.docx | DOCX document | |
| 73956 PD.pdf | ||
| Solicitation - FA857124Q0019.pdf | ||
| 73956 CDRL A001 Contractor_s Safety Plan.pdf | ||
| 73956 CDRL A002 Accident Incident Report.pdf |
Show all 16
Notice history
| Notice | Type | Posted |
|---|---|---|
| Fire Protection for Robins North | Award Notice | |
| Fire Protection for Robins North | Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity