Fire Hydrant Relocation
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest pre-solicitation from .
- Solicitation number
- FA940124B0003
- Agency
-
Nuclear Weapons Center
Air Force Materiel Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 237110 Water and Sewer Line and Related Structures Construction
- PSC
- S114 Utilities- Water
- Place of performance
- Albuquerque, New Mexico 87111, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Materiel Command Nuclear Weapons Center is seeking sources to perform the renovation of the current Fire Hydrant System at Kirtland Air Force Base in New Mexico. The work involves capping three existing fire hydrants, installing two new fire hydrants and two new isolation valves, and performing related civil, mechanical, and demolition work. Key requirements include providing shop drawings for government approval, complying with various airfield, construction, and safety codes/standards, obtaining necessary permits and waivers, coordinating access and schedules with the airfield, and providing a complete and warranted project. The period of performance is 207 calendar days from contract award.
This opportunity is set aside for small businesses under NAICS code 237110 - Water and Sewer Line and Related Structures Construction, with a $45 million size standard. The Air Force reserves the right to consider a small business set-aside for the subsequent competitive acquisition. Interested businesses must provide a statement of capabilities demonstrating experience with concrete construction projects by June 14, 2024.
Notice text
This is the initial step in the planning process for the renovation of the current Fire Hydrant System.
Files
| File | Type | Posted |
|---|---|---|
| Sources Sought.pdf | ||
| SoW MHMV 100217 Hydrants-Build_Final r.1.pdf | ||
| Sources Sought.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Replace Two 12, 470V to 480V Transformers | Award Notice | |
| MHMV 230056, Replace Two 12, 470V to 480V Transformers | Pre-Solicitation | |
| Replace Two 12, 470V to 480V Transformers | Solicitation | |
| This notice | Pre-Solicitation | |
| MHMV 230056, Replace Two 12, 470V to 480V Transformers | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Fire Alarm/Suppression Inspection, Testing, and Maintenance | Air Force Research Laboratory | No set-aside | |
| 2-STEP SEALED BID - TINKER AFB WWYK250019 Remove and Replace Fire Sprinkler in Plasma Booth Dust Collectors and Replace the Building F/A System, B3221 | Air Force Sustainment Center | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity