FEMA Region VI: Motor Control Panel Replacement
Closed Pre-Solicitation Posted
- Solicitation number
- 0909202602
- Agency
-
Federal Emergency Management Agency
Department of Homeland Security
- Responses due
- Set-aside
- Woman-Owned Small Business
Opportunity facts
- NAICS code
- 221122 Electric Power Distribution
- PSC
- S112 Utilities- Electric
- Place of performance
- Denton, Texas, United States
Notice details come from SAM.gov. Updated .
About this opportunity
FEMA Region VI intends to solicit a Woman-Owned Small Business contractor for the Electric Motor Control Center Replacement project at its facility in Denton, Texas, with a presolicitation response deadline of September 9, 2026. The requirement is set aside for eligible SBA Certified WOSB concerns under the Women-Owned Small Business Program.
Work is located at 800 North Loop 288, Denton, Texas 76209, and the contractor must demonstrate the ability to perform within a 150-mile radius of Denton. The project scope includes removal of the existing aging electrical main panel (installed in 1962), installation of a new modern motor control center with panels, wiring, breakers, switches, and mounting hardware, integration with existing facility infrastructure, implementation of safety protocols, safe removal and disposal of hazardous materials, inspections, quality assurance, cleanup, and final project documentation.
The contractor must provide qualified personnel including skilled, licensed journeymen electricians and a dedicated foreman or site supervisor. All contractor personnel require background investigations and security clearances appropriate to their job functions, U.S. citizenship or permanent residency status, and completion of required security training including unauthorized disclosure, OPSEC, and insider threat awareness briefings.
Period of performance is 90 days from Notice to Proceed, with deliverable milestones including planning and preparation within 14 days, roster submission within 2 days, demolition and removal within 35 days of planning completion, installation within 35 days of demolition completion, cleanup within 3 days of installation, and final inspection and reporting within 1 day. Work must comply with OSHA, NFPA 70E, and applicable local electrical standards. A one-year warranty on parts and labor is required following final government acceptance.
NAICS 221122 (Electric Power Distribution); PSC S112 (Utilities—Electric).
Notice text
Agency: Department of Homeland Security
Sub-Agency: Federal Emergency Management Agency
Office: FEMA Region 6
FEMA Region 6 intends to issue a solicitation for the Electric Motor Control Center Replacement project at the FEMA Region 6 facility located at 800 North Loop 288, Denton, Texas 76209.
The purpose of this project is to replace the facility’s aging Electric Motor Control Center, also referred to as the electrical main panel, to support operational continuity, improve safety, reduce operational risk, and ensure compliance with applicable regulatory requirements.
The anticipated work includes removal of the existing deteriorated electrical main panel and associated components; installation of a new modern motor control center; installation of panels, wiring, breakers, switches, mounting hardware, and replacement parts; integration of the new system with existing facility infrastructure; implementation of safety protocols; safe removal and disposal of obsolete electrical components and hazardous materials; inspections; quality assurance checks; cleanup; and final project documentation.
The contractor will be expected to provide qualified personnel, including skilled, licensed journeymen electricians and a dedicated foreman or site supervisor for oversight, coordination, and quality assurance. The contractor will also be expected to develop and maintain a comprehensive project schedule, minimize disruption to facility operations, maintain uninterrupted electrical service to critical areas wherever possible, and provide temporary power solutions as needed.
This requirement is anticipated to be set aside for eligible SBA Certified Women-Owned Small Business (WOSB) concerns under the Women-Owned Small Business Program.
Due to the mission-critical nature of this requirement and the need for timely response and completion of work, the Government requires the contractor to demonstrate the ability to perform within a 150-mile radius of Denton, Texas.
Site Visit
A site visit will be conducted as follows:
Date: Wednesday, September 9, 2026
Time: 10:00 a.m. Central Time
Location: FEMA Region 6 Campus, Federal Regional Center
Address: 800 N. Loop 288, Denton, TX 76209
Attendance at the site visit is not required but is strongly encouraged.
Offerors are requested to bring business cards to the site visit, if available.
All interested vendors that intend to attend the site visit should submit the following information to Contract Specialist Barbara Gonzalez no later than 7:00 a.m. Central Time on Tuesday, September 8, 2026:
- Company name
- Primary point of contact name
- Phone number
- Names of all attendees who will represent the firm at the site visit
Site visit attendance information shall be sent to:
Barbara Gonzalez
Contract Specialist
barbara.gonzalez@fema.dhs.gov
Anticipated Solicitation Posting
The full solicitation, including the Statement of Objectives, specifications, drawings, applicable clauses, provisions, and submission instructions, is anticipated to be posted to SAM.gov. Interested vendors are responsible for monitoring SAM.gov for the solicitation and any amendments.
Tentative Offer Due Date
Tentative offers will be due no later than:
Date: Wednesday, September 16, 2026
Time: 12:00 noon Central Time
Quotes or proposals shall be submitted in accordance with the instructions provided in the solicitation. Unless otherwise stated in the solicitation, submissions shall be emailed to:
Barbara Gonzalez
Contract Specialist
barbara.gonzalez@fema.dhs.gov
Neddra Tucker
Contracting Officer
neddra.tucker@fema.dhs.gov
Classification Information
Set-Aside: SBA Certified Women-Owned Small Business Program Set-Aside
FAR Reference: FAR 19.15
NAICS Code: 221122, Utilities, Electric
Place of Performance: Denton, TX 76209, United States
Evaluation Information
The evaluation will be conducted in accordance with FAR 52.212-2 and the evaluation factors stated in the solicitation. Due to the mission-critical nature of this requirement and the need for timely response and completion of work, the Government requires the contractor to demonstrate the ability to perform within a 150-mile radius of Denton, Texas.
A site visit will be conducted on Tuesday, September 8, 2026, at 10:00 a.m. Central Time at FEMA Region 6 Campus, 800 N. Loop 288, Denton, TX 76209. Attendance at the site visit is not required but is strongly encouraged. Offerors are requested to bring business cards to the site visit, if available.
Files
| File | Type | Posted |
|---|---|---|
| SOO - Electric Panel Motor Control Center - Draft.pdf |
On GovTribe