About this opportunity

The CDC Office of Acquisition Services seeks preventative maintenance and ISO/IEC 17025 accredited calibration of four environmental chambers at the NIOSH Pittsburgh campus, with proposals due May 19. The procurement is a total small business set-aside conducted under FAR Subpart 13.1 Simplified Acquisition Procedures as a firm fixed-price RFQ for commercial items.

Place of performance is the NIOSH Bruceton Campus, Building 40, 626 Cochrans Mill Road, Pittsburgh, Pennsylvania 15236. The work must be completed on or before June 30, 2026, within six months of contract award. The vendor must perform standard preventative maintenance per manufacturer specifications for four Russells Technical Products environmental chambers (models WMD-1407-20-HCD-1125-5-AC, WMD-288-GCMD-6-6-AC, WMD-900-30-30-MUA-AC, and WMD-900-30-30-MUA-60-AC) and deliver ISO/IEC 17025 accredited calibration across five temperature points (−50.0°C, −17.5°C, 15.0°C, 47.5°C, 80.0°C) and five humidity levels (0.0%, 22.5%, 45.0%, 67.5%, 90.0% RH at 40.0°C). Section 10 requires performance by either Russells Technical Products, Inc. or their authorized subcontractor. Calibration results and 17025 calibration certificates must be delivered within one week of completion. The vendor must coordinate with government technicians prior to travel; typical working hours are 9:00 AM to 3:30 PM. All travel costs are included in the contract price. The government provides facility access, electrical connections, compressed air, and municipal water connections; spare parts inventory is unavailable. NAICS code is 333415; PSC code is 6636.

Notice text

The purpose of this contract is for the preventative maintenance and ISO/IEC 17025 accredited calibration of four environmental chambers located on the NIOSH Pittsburgh campus. The equipment requires basic maintenance and regular calibration in order to maintain ISO/IEC 17025 accreditation and to be able to accurately conduct respirator approval and audit testing..

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Preventative Maintenance Gas Detection System (Re-Bid) Cherry Point, North Carolina 28533, United States · NAICS 811310 Naval Air Systems Command Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity