Establish new contract for Effluent Decontamination System and fund base year f

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
68HERC24Q0132
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

More information

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. EPA, Office of Research and Development (ORD), Safety, Health, and Environment Management Program (SHEM) located in Cincinnati, OH has a requirement for a multi-year comprehensive service program for the performance of preventative maintenance and unscheduled repair of the WR2 Effluent Decontamination System. The EPA intends to negotiate on a sole source basis with Biosafe Engineering for the maintenance of this system, which includes labor and travel costs, and a warranty on all parts installed. The procurement will be accomplished under FAR Part 12 Commercial Procedures and FAR Part 13 Simplified Acquisition Procedures, with the government intent to award a single, firm-fixed price purchase order.

This procurement has a NAICS code of 562211, Hazardous Waste Treatment and Disposal, with a size standard of $47.0M. The EPA requires two (2) preventive maintenance inspections during a twelve-month period, and the contractor shall provide a warranty on all parts installed for a minimum of ninety (90) days following installation. Responses to this notice must be received by 12:00pm Eastern Time on June 17, 2024, and a determination not to compete this acquisition based on responses is solely within the discretion of the government.

Notice text

Synopsis: Preventative Maintenance Contract for the AWBERC WR2 Effluent Decontamination System
The U.S. EPA, Office of Research and Development (ORD), Safety, Health, and Environment Management Program (SHEM) located in Cincinnati, OH has a requirement for a multi-year comprehensive service program for the performance of preventative maintenance and unscheduled repair of the WR2 Effluent Decontamination System (wastewater sterilizer, serial number 031006) located in the subbasement of the Andrew W. Breidenbach Environmental Research Center. The EPA intends to negotiate on a sole source basis, under the authority of FAR 13.106-1(b)(i) with Biosafe Engineering for the maintenance of this system. NAICS Code 562211, Hazardous Waste Treatment and Disposal, applies to this procurement and the size standard is $47.0M. This procurement consists of maintaining the WR2 Effluent Decontamination System according to factory specifications and to ensure that the instrument meets or exceeds the State of Ohio biohazardous waste regulations. This includes all labor and travel costs.
The EPA requires two (2) preventive maintenance inspections during a twelve-month period. The contractor shall provide a warranty on all parts installed at the end of this contract. Such warranty on parts shall be effective for a minimum of ninety (90) days following installation of such parts on covered equipment. Specifics of the coverage on this agreement include but are not limited to the following:
a) Certification that all thermocouples are each accurately calibrated against a NIST traceable standard.
b) The pressure sensor is to be checked and tested for accuracy.
c) The HEPA filter on the unit is to be replaced during one of the two preventative maintenance inspections.
d) During the first preventive maintenance inspection and after decontamination, the unit is to be opened and checked for corrosion, scale formation and/or wear. As a preventative measure, descaling of the interior, heating coil, and cooling coil is to occur and will involve the following:
i) The Contractor shall supply dry citric acid flake (150 kg or more) along with the proper drums, supply pumps, and hoses needed for injection.
ii) Using the dry citric acid crystals, a 5-10% aqueous citric acid will be prepared and injected into the empty vessel.
iii) After injection of the citric acid solution, the WR2 Effluent Decontamination System will be either heated or run through a complete cycle.
iv) After the cycle is completed and the instrument has cooled, the manway door will be opened, and the efficacy of the descaling procedure will be evaluated. If the Project Officer determines on inspection that excessive residual scale remains on the heating and cooling coils, then this descaling procedure will be repeated during the second preventive maintenance inspection.
v) After the descaling treatment, the drums, pump, delivery hose, and other equipment will be disconnected and returned to the Contractor and will not be stored at the AWBERC U.S. EPA site.
vi) The acid injection port will be isolated, so the unit will run normally.
e) The Man-way gasket is to be replaced and checked for leakage after installation.
f) Lubricate and check the torque on the Man-way bolts.
g) The control panel is to be inspected for proper operation.
h) The PLC/controllers are to be inspected for proper operation and overhauled or replaced if necessary.
i) The remote diagnostic capability using the remote interface installed in 2019 shall be tested/verified.
j) All solenoid valves are to be checked for proper operation.
k) All ball valves and actuators are to be inspected and rebuilt if necessary.

l) The unit is to be checked for leaks.
m) The dry well used for spore testing is to be examined and the lid gasket checked for integrity. The gasket is to be replaced if it shows signs of wear.
This procurement will be accomplished under FAR Part 12 Commercial Procedures and FAR Part 13 Simplified Acquisition Procedures. It is the Government intent to award a single, firm-fixed price purchase order. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETATIVE QUOTATIONS. This notice satisfies the requirement at FAR 5.201(b)(1) for publicizing the proposed contract action. Sources wishing to be considered MUST submit documentation to the office identified in this notice. Supporting evidence must be furnished in enough detail to demonstrate compliance. Information MUST be sent electronically via email to: Bryan Sweeney, Contract Specialist, sweeney.bryan@epa.gov. Telephone requests will not be honored. Responses must be received by 12:00pm Eastern Time on June 17, 2024. A determination not to compete this acquisition based on responses to this notice are solely within the discretion of the Government.
Contracting Office Address:
CAD
US Environmental Protection Agency
26 West Martin Luther King Drive
Mail Code: W136
Cincinnati OH, 45268-0001
USA
Place of Performance:
US Environmental Protection Agency
National Risk Management
Research Lab
26 W Martin Luther King Dr
Cincinnati OH, 45258
USA
Point of Contact(s): Contract Specialist Bryan Sweeney sweeney.bryan@epa.gov
Contracting Officer Mark Ingram Ingram.mark@epa.gov

Notice history

Notice Type Posted
Establish new contract for Effluent Decontaminatio Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Sources Sought and RFI (Recompete 68HERC21D0006) NAICS 541620 — No set-aside
Single Purchase of an Agilent 8890 GC System Custom with dual ECD detectors NAICS 221310 EPA Region 4 No set-aside
Request for Information (RFI) NAICS 562910 — No set-aside
Wastewater pretreatment plant operation and maintenance services Washington, District of Columbia 20228, United States · NAICS 561210 Bureau of Engraving and Printing Competitive 8(a)
Waste Water Treatment Plant Services Praia da Vitoria Azores 9760- Portugal · NAICS 221320 Air Forces Europe and Africa No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity