Elevator and Escalator Inspection and Maintenance Services at the Bonneville Lock and Dam Project
Closed Solicitation Posted
- Solicitation number
- W9127N21Q0001
- Agency
-
ENDIST Portland
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Place of performance
- Cascade Locks OR 97014 USA
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks offers to provide elevator and escalator inspection and maintenance services at the Bonneville Lock and Dam Project for the U.S. Army Corps of Engineers, Portland District. The contractor shall perform full services including monthly, annual, biennial, and five-year inspections for 20 elevators and escalators in compliance with applicable safety codes and manufacturer recommendations. A mandatory site visit is scheduled for December 3, 2020. The agency will award a firm fixed-price, performance-based service contract and include option years. Offerors must have an active SAM registration by the December 10, 2020 submission deadline.
There are no set-asides designated for this requirement. It is classified under NAICS code 811310 with an $8 million size standard and is unrestricted. Performance will take place at the Bonneville Dam Security Office in Cascade Locks, Oregon. Inspections include cleaning, lubrication, adjustment, calibration and repairs to maintain the equipment condition. The solicitation seeks a commercial, performance-based service contract for full elevator repair and maintenance services.
Notice text
Description of Services: The Contractor shall provide full elevator repair and maintenance services at Bonneville Lock and Dam. Elevator and escalator services are for the monthly inspections and maintenance of 20 elevators/escalators and all necessary work performed relative to cleaning, lubrication, adjustment and calibration of the equipment where applicable to return each elevator to the specified condition. Inspection schedules include monthly, annual, every two-year, and five-year inspections. Maintenance services shall be in compliance with American Society of Mechanical Engineers (ASME) Safety Code for Elevators and Escalators, ASME 17.1, Oregon Elevator Specialty Code (OAR 918-400-0455 and 918-400-0458), and Washington Administrative Code (WAC 296-96-00500), as well as the manufacturer’s recommendations and other applicable laws, regulations, rules, ordinances, codes.
A Site Visit date is set for 3 Dec 2020. Meeting location: Bonneville Dam Security Office, HWY 84, exit 40, Cascade Locks, OR 97014. See RFQ for details.
Contract type: This RFQ will result in a firm fixed price commercial, performance-based servicecontract. The Government will include options in the contract.
Set Aside and Codes: This is an unrestricted, full and open acquisition. This effort is classified through the North American Industry Classification System (NAICS) under code 811310 – Commercial and Industrial Machinery and Equipment ($8M). The FSC is J035 – Maintenance, Repair, and Rebuilding of Equipment- Service and Trade Equipment.
All contractors are required to be register and maintain an active SAM entity registration in order to be eligible for contract awards, as prescribed by the regulation at FAR Subpart 4.11. In order to eligible for the contract award resulting from this solicitation, Offerors are advised to take immediate action to ensure your SAM entity registration is current and/or will be current at the time of proposal receipt by this contracting office.
Quoters are reminded to review the RFQ for instructions on the submission of questions with respect to this RFQ.
Files
| File | Type | Posted |
|---|---|---|
| B.08 W9127N21Q0001 Elevator Maintenance Bonn Final RFQ package.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Elevator and Escalator Inspection and Maintenance Services at the Bonneville Lock and Dam Project | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Bonneville Powerhouse II Unwatering Pump Replacement | ENDIST Portland | Total Small Business | |
| John Day Below-the-Hook Lifting Devices Repair and Recertification | ENDIST Portland | No set-aside | |
| Elevator Repair and Maintenance Support Services | ACC Aberdeen Proving Ground | Total Small Business | |
| Navigation lock tainter valve (TV) repair, TV1 | ENDIST Portland | No set-aside | |
| John day DAM navigation lock tainter valve (TV) repairs TV3 and TV4 | ENDIST Portland | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity