About this opportunity

The Department of the Air Force Air Mobility Command is seeking an Architect-Engineer (A-E) to conduct an engineering design study for upgrading or replacing the outdated switchgear and motor control center equipment in Mission Buildings B820 and B830 at Cavalier Space Force Station in North Dakota. The scope of work requires the selected A-E to provide a Class 4 cost estimate and recommendations to modernize the power distribution system, optimizing energy efficiency, reliability, resiliency, and performance. The study must explore both upgrading the existing equipment with new technology and replacing the equipment through reengineering. The resulting design package will be used for a future solicitation. Interested parties are invited to submit a capabilities package by June 11, 2024.

This opportunity is not set aside for any particular business size or type. The applicable NAICS code is 541330 - Engineering Services. No potential incumbents or current contractors are named. The pre-solicitation notice does not provide any information about award values or budget ranges. The timeline for services is not explicitly stated, but the engineering design study is the focus of the current requirement.

Notice text

“Scope of Work: The Architect-Engineer (A-E) shall conduct an engineering design study, to include a Class 4 cost estimate (accuracy defined as – 20% to +30%) and provide recommendations to upgrade and/or replace the existing outdated switchgear and motor control center equipment in Mission Buildings B820 and B830 at Cavalier Space Force Station (CSFS), North Dakota.

Goal: Provide cost effective, feasible, and sustainable options that will upgrade the Tactical Support Switchgear (SWGR) and Motor Control Centers (MCC) while optimizing the p[power distributions system’s energy efficiency, reliability, resiliency and performance. The upgraded equipment, SWGE and MCC’s must retain their local and remote controls, their voltage and current protection and monitoring as well as any existing capabilities. Additionally, the study must be conducted within the context of the defined short-term and long-term mission requirements of CSFS. Given that existing manufactured parts are no longer available to conduct routine and preventative maintenance on the switchgear and corresponding equipment, the study must explore both upgrading the existing equipment with modernized technology as well as replacing the existing equipment via reengineering.

Files

Notice history

Notice Type Posted
EGYN121012E Repair Outdated Electrical Switchgear Study B820-830 Latest pre-solicitation Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Architect and Engineering Services Ohio 44473, United States · NAICS 541310 Reserve Command Total Small Business
Architect and Engineering Services Ohio 44473, United States · NAICS 541310 Reserve Command Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity