Doble Leasing for Hydropower Test Center SAD, SAM
Closed Pre-Solicitation Posted
- Solicitation number
- W9127824L0030
- Agency
- ENDIST Mobile US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334515 Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
- Place of performance
- Mobile, Alabama 36602, United States
- Points of contact
-
- Joan Rensink joan.a.rensink@usace.army.mil (251) 441-6172
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers, Mobile District, intends to solicit and negotiate a contract for the leasing of test equipment to be used at hydropower facilities in the Mobile and Savannah Districts. The equipment to be leased includes the M4100 Insulation Analyzer, M4110 Leakage Reactance Interface, M4300 Transport Cart, and MFL Liquid Test Cell and Carrying Case. This equipment is required to meet NERC standard PRC-005 and SAD maintenance standards for generation equipment testing. The contract is anticipated to be a Fixed Price agreement under NAICS code 334515, with a size standard of 750 employees. Interested parties are requested to provide capability statements within 15 days, which the government will review to determine if a competitive procurement is appropriate.
This opportunity is not set-aside, and the government intends to solicit and negotiate with only one source, Doble Engineering, 123 Felton St. Marlborough, MA 01752 USA, under the authority of FAR 6.302-1, Only One Responsible Source and No Other Supplier or Services Will Satisfy Agency Requirements. The contract value or budget range is not specified, but the equipment to be leased includes the items mentioned above.
Notice text
The government intends to solicit and negotiate with only one source, Doble Engineering, 123 Felton St. Marlborough, MA 01752 USA under the authority of FAR 6.302-1, Only One Responsible Source and No Other Supplier or Services Will Satisfy Agency Requirements. Doble test equipment is required to meet NERC standard PRC-005, as well as all SAD maintenance standards regarding generation equipment testing. Equipment that is to be leased includes M4100 Insulation Analyzer, M4110 Leakage Reactance Interface, M4300 Transport Cart (used to move the M4100), and MFL Liquid Test Cell and Carrying Case. See attached
Attachments
| File | Type | Posted |
|---|---|---|
| W9127824L0030 Special Notice to Sole Source.pdf |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity