The Department of the Air Force Special Operations Command at Cannon Air Force Base, New Mexico is procuring one DMC Duplex Pump Control Panel (460V/7.5 HP) with specialized technical specifications including surge protection, phase monitoring, NEMA starters, control power transformer, and alarm system, along with four Flygt ENM-10 Liquid Level Sensors with 40-foot cables to replace an inoperative unit in Building 1402. The procurement includes both purchase and installation services for this critical infrastructure replacement. Vendors must be registered in the System for Award Management and will be evaluated based on technical acceptability, past performance, and price, with the award going to the lowest-priced, technically acceptable vendor. The solicitation was issued on June 23, 2025, with questions due by June 26, 2025, and quotes due by July 3, 2025 at 2:30 PM Mountain Daylight Time. All quotes must be submitted via email to designated contracting personnel, with specific formatting requirements and restrictions on file submissions.

This procurement is designated as a 100% total small business set-aside under NAICS code 335314 (Relay and Industrial Control Manufacturing) with a size standard of 750 employees. The solicitation includes a single source justification document indicating the government's preference for Flygt brand components to maintain compatibility with the existing lift station system, suggesting that Flygt or its authorized dealers may have a competitive advantage. While no specific contract value is disclosed in the available documents, the procurement involves specialized industrial control equipment and professional installation services. The work will be performed at Cannon Air Force Base in Clovis, New Mexico, specifically at Building 1402 where the existing inoperative lift station control panel requires replacement. The government will not provide contract financing, with invoice instructions to be provided upon award.

Notice text

2 versions

Update #2 · Latest ·

Cannon AFB, NM requires requires the purchase of one (1) DMC Duplex Pump Control Panel (FLOAT) 460V / 7.5 HP, N3R Painted Galv Encl w/ Inner Swing Panel, Main CB, Surge Protection, Phase Monitor, Pump CBs, CB for External Transformer, NEMA Starters, Control Power Transformer, Pump Alternator w/ SW, 22mm Pilots and SW, ETMs, Alarm Buzzer w/ Integral Silence, Dry Contacts and Four (4) Flygt ENM-10 Liquid Level Sensors w/ 40' Cable. Including installation. This is to replace the current inoperative one located in BLDG 1402.

Update #1 ·

Cannon AFB, NM requires requires the purchase and installation of one (1) DMC Duplex Pump Control Panel (FLOAT) 460V / 7.5 HP, N3R Painted Galv Encl w/ Inner Swing Panel, Main CB, Surge Protection, Phase Monitor, Pump CBs, CB for External Transformer, NEMA Starters, Control Power Transformer, Pump Alternator w/ SW, 22mm Pilots and SW, ETMs, Alarm Buzzer w/ Integral Silence, Dry Contacts and Four (4) Flygt ENM-10 Liquid Level Sensors w/ 40' Cable. Including installation. This is to replace the current inoperative one located in BLDG 1402.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Small Arms Firing Range (SAFR) Cleaning and Maintenance Services Cannon AFB, New Mexico 88103, United States · NAICS 562910 Air Force Special Operations Command Total Small Business
Pump, centrifugal NAICS 333914 Land and Maritime No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity