Det 1 Fuel Tank

Closed Solicitation Posted

Solicitation number
W50S78-26-Q-A004
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

PSC
9140 Fuel Oils
Place of performance
Jbsa Lackland, Texas 78236, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army National Guard seeks procurement of one 1000-gallon diesel fuel tank with secondary containment and associated dispensing equipment, with proposals due September 2, 2026 at 2:00 PM local time. The procurement is set aside 100% for women-owned small business (WOSB) concerns.

Place of performance is Lackland Air Force Base, Texas (DoDAAC F9J1DT), with delivery required within 60 calendar days from award. The specification calls for an Envirosafe FG Cube 1000-gallon fuel tank or equal, with secondary containment, standard and emergency vents, powered fuel pump delivering a minimum flow rate of 10 gallons per minute with metered capability, and a 25-foot retractable hose with reel. The tank must be corrosion-resistant and rated for outdoor continuous operation across an ambient temperature range of –20°F to 120°F. All exterior surfaces and non-metallic components must retain at least 90% tensile strength and resist cracking or chalking after a minimum of 1,000 hours of UV exposure per ASTM G154 or ASTM D432. All electrical control boxes, valves, and auxiliary electronic components must be rated NEMA 4X (watertight, dust-tight, and corrosion-resistant).

NAICS code is 332420 (Metal Tank Heavy Gauge Manufacturing) with a size standard of 750 employees. PSC code is 9140 (Fuel Oils). The contract is firm fixed price. Evaluation factors are price and technical acceptance, with a 10% price evaluation preference available to HUBZone small business concerns that do not waive the preference. Contact is Mark Green at 945-7127.

Notice text

The 149th FW has a requirement for a 1000 gallon fuel tank. Minimum Requirements for Storage and Dispensing of Diesel Fuel: 1000 gallon storage with secondary containment, tank needs standard and emergency vents, powered fuel pump meeting standard flow rates with metered capability, 25 foot retractable hose with reel, tank must be corrosion resistant to withstand prolonged environmental conditions. 

See attachments for full description:

1. Solicitation W50S78-26-Q-A004

2. Product Description - Fuel Tank

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Tank, fuel, engine NAICS 336390 Land and Maritime Woman-Owned Small Business
Tank, fuel, aircraft NAICS 336413 Aviation No set-aside
Tank, fuel, engine NAICS 336390 Land and Maritime Total Small Business
Tank, fuel, portable NAICS 336310 Land and Maritime No set-aside
Tank, fuel, engine NAICS 336310 Land and Maritime Total Small Business