DACA675260023200 - United States Army Corps of Engineers (USACE) seeks to lease approximately 6, 500 gross square feet of warehouse space in Seattle, WA for Storage & Laboratory Space
Closed Pre-Solicitation Posted
- Solicitation number
- DACA675260023200
- Agency
-
ENDIST Seattle
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 531120 Lessors of Nonresidential Buildings (except Miniwarehouses)
- Place of performance
- Seattle, Washington 98134, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The United States Army Corps of Engineers, Seattle District, intends to lease approximately 5,800 to 7,000 gross square feet of contiguous warehouse and laboratory space in Seattle, Washington, with proposals due by June 30, 2026. No set-aside is anticipated. The space must be located within a delineated area spanning Seattle's north end (bounded by Alaskan Way and Broad Street north to Interstate 5, then by Mercer Street, Lake Washington, and the Lake Washington coast south to Rainier Avenue, and by Puget Sound to the west) and must occupy a prime business park setting with modern or tastefully rehabilitated design.
The lease term is 60 months with annual option periods. The space must provide 24-hour unrestricted government access, parking for eight government vehicles plus private vehicle parking, loading dock capability (turning radius 35–45 feet; truck dimensions 15–35 feet length × 11–12 feet height × 96 inches width), freight elevator if above ground level, HVAC climate control maintaining 70–76 degrees Fahrenheit, 30-amp 110V electrical service, hot and cold water, garbage and recycling facilities, and sound proofing and isolation. Lessor must maintain all utilities with separate meters for government-only measurement and provide janitorial services and building maintenance.
The government will award to the offeror whose proposal represents best value considering price (including construction costs and potential lessor buildout contributions) and technical factors weighted approximately equally. Technical evaluation includes location, neighborhood characteristics, building access, floor plan efficiency, business adjacency compatibility, building appearance, electricity provision, and security features. Lease award requires OMB Circular A-11, Appendix B, operating lease qualification. Lessors must submit evidence of ownership or control, accessibility and fire protection compliance documentation, environmental and asbestos certifications, and SAM registration prior to award. Proposals should be emailed to cenwsre-rfp@usace.army.mil with questions directed to Kim La at (206) 858-1750 or thu.k.la@usace.army.mil.
Notice text
PRE-SOLICITATION NOTICE/ADVERTISEMENT – UNITED STATES ARMY CORPS OF ENGINEERS
The U.S. Government, by and through United States Army Corps of Engineers (USACE), seeks to lease the following space:
State: Washington
City: Seattle
Delineated Area:
North: Intersection of Alaskan Way and Broad St, north to 5th Ave N, east on Mercer St to Rt 5, then south on Rt 5 to east on E Mercer St, E Mercer St to south on 28th Ave, continue south onto Martin Luther King Jr Way E, then east to E Harrison St, continue E Harrison St onto Lake Washington Blvd E, Lake Washington Blvd E to Lake Washington Coast.
South: Intersection of Lake Washington coast and Rainier Ave S, east on Rainier Ave S to 51st Ave S, south on 51st Ave S to S Ryan Way, east on S Ryan Way continuing onto S Boeing Access Rd, S Boeing Access Rd to Rt 5, south on Rt 5 to Interurban Ave S, northwest on Interurban Ave S to S 133 St, south on S 133rd St to E Marginal Way S, north on E Marginal Way to S 130th St, S 130th St to S 132nd St, west on S 130th St to 24th Ave S, north on 24th Ave S to S 128th St, west on 128th to Ambaum Blvd SW, north on Ambaum Blvd SW to 16th Ave SW, north on 16th Ave SW to SW Roxbury St, west on SW Roxbury St to 34th Ave SW, north on 34th Ave SW to SW Barton St, west on SW Barton St continue through California Ave SW and SW Brace Point Dr to Coast of Puget Sound.
East: Intersection of Lake Washington Blvd E and Lake Washington Coast, south to Intersection of Lake Washington coast and Rainier Ave S.
West: Intersection of SW Brace Point Dr and coast of Puget Sound, north of intersection of SW Brace Point Dr and coast of Puget Sound to Broad St.
Gross Square Feet (ABOA): 5,800 to 7,000
Space Type: Warehouse
GOV Parking Spaces (Total): Eight (8)
Full Term: 60 months
Option Term: Annual/None
Additional Requirements:
- Space must be located in a prime business park area with attractive surroundings with a prevalence of modern design and/or tasteful rehabilitation in modern use.
- Space shall be located in a professional office setting and preferably not within close proximity to residential areas, railroad tracks, or power transmission lines.
- Space should not be located within the 100-year flood plain or wetland unless the Government has determined it to be the only practicable alternative.
- Space should not located near establishments whose primary operation is the sale of alcoholic beverages, firearms sold/discharged, marijuana dispensaries, or where there are tenants or invitees related to drug treatment or detention facilities.
- Employee and visitor entrances of the Building must be connected to public sidewalks or street by continuous, accessible sidewalks.
- Subleases are not acceptable.
- Space configuration shall be conducive to an efficient layout. Considerations for an efficient layout include, but are not limited to, the following: size and location of interior fire (support) walls, size and number of columns, column placement, bay depts, window size and placement, convector size and placement, electrical and telephone accessibility, and angles, curves, or offsets that will result in an inefficient use of space.
- The following space configurations will not be considered: Space with atriums and other areas interrupting contiguous space, extremely long or narrow runs of space (more than twice as long as wide), irregularly shaped space configurations or other unusual building features adversely affective usage.
- Columns cannot exceed two (2’) square feet and space between columns and/or walls cannot be less than twenty (20’) feet.
- The offered space must meet or be capable of meeting Government requirements for Security, Fire Life Safety and Handicapped Accessibility.
- The Government requires a fully serviced lease. All services, utilities, and tenant alterations are to be provided as part of the rental consideration.
- The Government will have access to the space 24 hours a day, 7 days a week. Normal hours of operation are Monday through Friday 0800 to 1700 (excluding weekends and Federal holidays).
Offered space must meet Government requirements for fire safety, accessibility, seismic, and sustainability standards per the term of the Lease. A fully serviced leased is required. Offered space shall not be in the 1-percent-annual change floodplain (formerly referred to as “100-year” floodplain). The government reserved the right to conduct a cost benefit analysis included move and replication costs.
Entities are advised to familiarize themselves with the telecommunications prohibitions outlined under Section 889 of the FY19 National Defense Authorization Act (NDAA), as implemented by the Federal Acquisition Regulation (FAR). For more information, visit: https://acquisition.gov/FAR-Case-2019-009/889_Part_B.
Expressions of Interest Instructions/Requirements:
Please provide the following basic information and descriptions pertaining to the building you propose for consideration.
All submissions should include the following information:
- Name of owner;
- Age of building;
- Total existing gross square feet;
- Site plan depicting the building and parking;
- Floor plan and gross square footage of the proposed space;
- Identification of on-site parking;
- Address or described location of building;
- Location on map demonstrating the building lies within the delineated area;
- A narrative and map describing proximity of the building to the nearest bus and/or train stop, and major transportation routes;
- Evidence of ownership, if building submitted by owner. Non-owners (e.g. brokers) must provide evidence of authority granted by property owner to submit the property;
- Any information related to title issues, easements, or restrictions on the use of the building; and
- Provide expected rental rate per rentable square foot.
Expressions of Interest Due: 06/30/2026
Market Survey (Estimated[EN1] ): 07/15/2026
Occupancy (Estimated): intermittent
Send Expressions of Interest to:
Realty Specialist Name: Kim La
Email Address: thu.k.la@usace.army.mil, cenwsre-rfp@usace.army.mil
Phone Number: (206) 858-1750
Government Contact Information: michael.l.arne@usace.army.mil; (206) 498-3911[EN2]
Real Estate Contracting Officer: Thomas Seymour
Files
Similar open opportunities
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners