CSS 99147 Mini Splits Scranton, PA (PA162)
Closed Solicitation Posted
- Solicitation number
- W15QKN-26-Q-A168
- Agency
-
ACC Picatinny
Army Contracting Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- PSC
- Z1AA Maintenance Of Office Buildings
- Place of performance
- Scranton, Pennsylvania 18509, United States
- Points of contact
- More information
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Contracting Command-Rock Island at Fort Dix seeks installation of a mini-split HVAC system, renovation of corridor walls in a heated storage building, and construction of perimeter fencing and gates at the Scranton Armed Forces Reserve Center in Pennsylvania, with proposals due August 28. The procurement is set aside for small business and requires submission through PIEE.
Place of performance is Dunmore, Pennsylvania 18509. The contract period runs 180 calendar days from notice to proceed, with work scheduled September 15, 2026 through March 14, 2027. Work hours are 0800–1630, Monday–Friday, excluding federal holidays.
The mini-split scope includes installation of a 208/230-volt single-phase heat pump with minimum SEER rating of 19 (approximately 15,000 BTU) in the Training Center computer room, complete with refrigerant lines, disconnect switch, electrical connections, condensate drain pump, and collection pan. HSB corridor work entails removal of existing finishes, installation of a commercial steel hollow metal door with panic device and electronic access controls, vinyl wall protection sheets (0.060 thick, 750 linear feet), stainless steel corner moldings, vinyl cove base molding, drywall patching and painting, and entrance canopy installation. MEP fence work requires removal of 32 linear feet of existing fence and installation of approximately 1,225 linear feet of 6-foot-high chain link fence with 3 strands of barbed wire (7-foot total height), a 42-foot aluminum cantilever slide gate, a 16-foot double swing gate, and six 8-inch concrete-filled pipe bollards. All concrete work must conform to ASTM C 94/C 94M with minimum 3000 psi compressive strength and shall not be performed below 38 degrees Fahrenheit.
NAICS code is 236220, Commercial and Institutional Building Construction, with a $45,000,000 size standard. Mandatory site visits occur August 19 or 20, 2026 at 10:00 AM EDT. Evaluation uses lowest price technically acceptable methodology. Performance and payment bonds are required and due within 10 calendar days of award. Bid guarantee of 20 percent of quote price or $3 million (whichever is less) is required for quoted prices exceeding $150,000. Davis-Bacon prevailing wage determination PA20260091 Mod 03 applies, effective through May 18, 2026.
Notice text
THIS SOLICITATION IS SET ASIDE FOR SMALL BUSINESS.
ALL PROPOSALS SHALL BE SUBMITTED THROUGH PIEE.
THE U.S.ARMY CONTRACTING COMMAND - ROCK ISLAND AT FORT DIX HAS A NEW CONSTRUCTION REQUIREMENT IN SUPPORT OF THE U.S. ARMY 99TH READINESS DIVISION. THIS PROJECTED IS LOCATED WITH THE 99TH READINESS DIVISION B REGION: CSS 99147 - INSTALL MINI SPLIT LOCATED AT THE SCRANTON AFRC 3401 OLYPHANT AVE SCRANTON, PA 18509.
Files
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Adal building 78, BCE and fire facility | Pennsylvania National Guard | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity