Commercial Diesel Generator Set, 600kW Standby 60Hz
Closed Solicitation Posted
- Solicitation number
- W911S226U3180
- Agency
-
MICC Fort Drum
Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 335312 Motor and Generator Manufacturing
- Place of performance
- 4525 Camp Hale Rd Fort Drum, NY 13602 13602
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum seeks a commercial diesel generator set, 600kW standby 60Hz, with proposals due May 13. This procurement is a Total Small Business set-aside, restricting competition to small business concerns.
Place of performance is Fort Drum, New York. The generator must meet specifications including 600DQCA model configuration, 60Hz frequency, 277/480 volts three-phase Wye four-wire output, EPA Tier 2 emission certification, UL 2200 listing, steel sound-attenuated Level 2 enclosure in green, 2400-gallon UL142-compliant sub-base fuel tank with dual stub-up connection, Power Command 2.3 controller with LCD display, 1200-amp three-pole circuit breaker rated at 100 percent, 24-volt DC spring-closed motorized louvers for cooling air inlet and outlet, external 12-amp regulated battery charger, radiator cooling with 50-degree Celsius ambient capability, coolant heater rated 208/240/480 volts AC for below-40-degree Fahrenheit ambient operation, low-coolant-level shutdown, and two-year base warranty. The NAICS code is 335312, Motor and Generator Manufacturing; PSC code is 6115, Generators and Generator Sets, Electrical.
Notice text
2 versions
Update #2 · Latest ·
Amended to include set aside code. Characteristics:600DQCA, Diesel Genset, 60Hz, 600kW, Duty Rating - Standby Power (ESP), Emission Certification, EPA, Tier 2, NSPS CI Stationary Emergency, Listing- UL 2200, Voltage - 277/480, 3 Phase, Wye, 4 Wire, Alternator - 60Hz, Wye, 480 Volts,105C ? Standby, Alternator Heater, 120 Volt AC, Steel Sound Attenuated Level 2Enclosure, with Exhaust System, Enclosure Color - Green, Steel, Cooling Air Outlet -Horizontal, Sound Attenuated, Louvers - Air Inlet, 24 Volts DC Spring Closed, Motor Opened, Louvers - Air Outlet, 24 Volts DC Spring Closed, Motor Opened, Distribution Panel - Prewired AC Features, Fuel Tank - Sub Base, 2400 Gallon, UL142 Compliant, Listing, ULC - S601 ? 07, Alarm - High Fuel Fill, Fuel Tank Connection - Dual Stub Up,Fuel Water Separator, Control Mounting - Left Facing, Power Command 2.3 Controller, LCD Control Display, Stop Switch - Emergency, Externally Mounted, Signals - Auxiliary,8 Inputs/8 Outputs, Control Display Language ? English, Circuit Breaker or Entrance Boxor Terminal Box - Right Only, Terminal Box- Low Voltage, Left- None, Circuit Breaker -1200A, Right, 3P, UL 600, IEC 415, UL Serv Ent, 100%, Circuit Breaker or Entrance Boxor Terminal Box, Top Entry, Left- None, Bottom Entry, Right, Engine Air Cleaner - Normal Duty, External Battery Charger - 12 Amp, Regulated, Engine Cooling - Radiator, 50CAmbient, Shutdown - Low Coolant Level, Coolant Heater - 208/240/480 Volts AC, Below40F Ambient Temperature, Genset Warranty - 2 Years Base, Literature ? English, Packing -None, Base Mounted Housing, OTECD, OTEC Transfer Switch- Electronic Control:
Update #1 ·
Characteristics:600DQCA, Diesel Genset, 60Hz, 600kW, Duty Rating - Standby Power (ESP), Emission Certification, EPA, Tier 2, NSPS CI Stationary Emergency, Listing- UL 2200, Voltage - 277/480, 3 Phase, Wye, 4 Wire, Alternator - 60Hz, Wye, 480 Volts,105C ? Standby, Alternator Heater, 120 Volt AC, Steel Sound Attenuated Level 2Enclosure, with Exhaust System, Enclosure Color - Green, Steel, Cooling Air Outlet -Horizontal, Sound Attenuated, Louvers - Air Inlet, 24 Volts DC Spring Closed, Motor Opened, Louvers - Air Outlet, 24 Volts DC Spring Closed, Motor Opened, Distribution Panel - Prewired AC Features, Fuel Tank - Sub Base, 2400 Gallon, UL142 Compliant, Listing, ULC - S601 ? 07, Alarm - High Fuel Fill, Fuel Tank Connection - Dual Stub Up,Fuel Water Separator, Control Mounting - Left Facing, Power Command 2.3 Controller, LCD Control Display, Stop Switch - Emergency, Externally Mounted, Signals - Auxiliary,8 Inputs/8 Outputs, Control Display Language ? English, Circuit Breaker or Entrance Boxor Terminal Box - Right Only, Terminal Box- Low Voltage, Left- None, Circuit Breaker -1200A, Right, 3P, UL 600, IEC 415, UL Serv Ent, 100%, Circuit Breaker or Entrance Boxor Terminal Box, Top Entry, Left- None, Bottom Entry, Right, Engine Air Cleaner - Normal Duty, External Battery Charger - 12 Amp, Regulated, Engine Cooling - Radiator, 50CAmbient, Shutdown - Low Coolant Level, Coolant Heater - 208/240/480 Volts AC, Below40F Ambient Temperature, Genset Warranty - 2 Years Base, Literature ? English, Packing -None, Base Mounted Housing, OTECD, OTEC Transfer Switch- Electronic Control:
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Portable Solar Generator | MICC Fort Drum | Total Small Business | |
| Diesel Engine, Starter Motor, Magnetic Contactors, Powerpack & Alternators Supporting 800kW, 60 Hz DPGDS - Non-Commercial NSN's | Land and Maritime | No set-aside | |
| Reciprocating Air Compressor | MICC Fort Drum | Total Small Business | |
| Sources Sought – FY27 Temporary Backup Generator and Transformer Lease and Sustainment – Winn Army Community Hospital, Fort Stewart, Georgia | Mission and Installation Contracting Command | No set-aside | |
| Emergency Diesel Generator and Automatic Transfer Switch Rental | Naval Sea Systems Command | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity