Air Mobility Command is preparing to procure a breathing air compressor system for the 436th Civil Engineer Squadron Fire Department at Dover Air Force Base, Delaware, with responses due by June 23, 2026. This is a Total Small Business set-aside. The Bauer brand is required due to integration with existing service contract FA449725C0008; substitution of a different brand would void the current service contract, compromise operational continuity of life-safety equipment, and result in increased costs, loss of warranty coverage, and potential non-compliance with NFPA standards.

The system must be NFPA 1901 and 1989 (current edition) compliant and include a 6,000 PSI all-in-one unit rated 15–25 horsepower, three SCBA fill stations accommodating cylinders up to 31 inches overall length, a 100-foot high-pressure cabinet-enclosed hose reel, a sound-attenuating enclosure with slam-action latches, an automatic condensate drain system with noncorrosive reservoir and integrated float sensor with automatic "Full" indication and compressor shutdown, and safety alarms with an emergency stop button. Contact TSgt Grant Hadrava, NCOIC Logistics, 436 CES/CEF, at Grant.hadrava@us.af.mil or (302) 677-4414 for questions.

Notice text

The Government requires a breathing air compressor system for use by fire department emergency responders. The system must be NFPA 1901 and 1989 (current edition) compliant and include: an all-in-one unit with 6,000 PSI storage capacity and 15-25 horsepower; three SCBA fill stations accommodating cylinders up to 31" overall length; a 100-foot high-pressure cabinetenclosed hose reel; a sound-attenuating enclosure with slam-action latches; an automatic condensate drain system with a noncorrosive reservoir, integrated float sensor, and automatic "Full" indication with compressor shutdown; and safety alarms with an emergency stop button. Due to an existing breathing air system currently under service contract FA449725C0008, the Bauer brand is required due to unit integration. Procuring a different brand would be incompatible with the existing service infrastructure, would void the current service contract, and could compromise the safety and operational continuity of life-safety equipment used by emergency responders. Substitution of a different brand would result in increased costs, loss of warranty coverage, and potential non-compliance with NFPA standards as configured.

Files

Notice history

Notice Type Posted
CE SCBA Air Compressor Latest pre-solicitation Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Bauer Rebuild Kit Tinker AFB, Oklahoma 73145, United States · NAICS 333912 Air Force Sustainment Center Total Small Business
Breathing apparatus, SE NAICS 326299 Construction and Equipment Total Small Business
Hub, air compressor NAICS 333912 Land and Maritime Total Small Business
Parts kit, compressor NAICS 333912 Land and Maritime Total Small Business
Piston, compressor NAICS 333912 Land and Maritime Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity