Cascade SCBA system

Closed Solicitation Posted

Solicitation number
W911S225U1548
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Deliver to address: James FerraroBLDG: 772: 6446-Indiana Ave.Fort Leonard Wood, MO. 65473 65473

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum is procuring a CASCADE SCBA (Self-Contained Breathing Apparatus) System through this solicitation. The system requires extensive technical specifications including a NEMA 4 rated electrical enclosure with UL listed control panel, a minimum 5-stage compressor with 20 HP electric motor, and capability to produce 6000 PSI with a charging rate of at least 25 SCFM. Critical safety features must include CO/H2S monitoring systems with audible alarms, emergency stop functionality, automatic condensate drain systems, and comprehensive safety shutdowns for low oil pressure and high temperature conditions. The system must be capable of simultaneously filling three SCBA or SCUBA cylinders and include a NFPA 1901 2016 Edition compliant 3-position containment fill station. The solicitation was posted on August 12, 2025, with responses due by August 20, 2025, providing contractors with an eight-day response window after an amendment extended the original one-day timeline.

This opportunity is designated as a Total Small Business set-aside, restricting competition to qualified small business entities. The solicitation falls under NAICS code 334519 (Other Measuring and Controlling Device Manufacturing) and PSC code 4240 (Safety and Rescue Equipment), indicating the specialized nature of the breathing apparatus system being procured. Performance will take place at Fort Leonard Wood, Missouri, specifically at 6446 Indiana Ave, Fort Leonard Wood, MO 65473. The system specifications indicate this is likely a single-unit procurement given the detailed technical requirements for one comprehensive CASCADE SCBA system. No incumbent contractors, specific award values, or budget ranges are identified in the solicitation notice.

Notice text

2 versions

Update #2 · Latest ·

Implemented Amendment only opened for a day pushed to 7 days. UNICUS IV:MUST HAVE A NEMA 4 RATED ELECTRICAL ENCLOSURE w/ UL LISTED CONTROL PANELMUST COME WITH PARTS AND REPAIR MANUALSMUST HAVE AIR INLET FILTER MAINTENANCE INDICATORMUST HAVE A VIRUS FREE INTAKE FILTERATION SYSTEMMUST HAVE (4) ASME CODE STAMPED AIR CYLINDERS INSTALLED IN AN INTEGRAL RACKMUST HAVE A P5 B-SECURUS PURIFICATION SYSTEMMUST BE AT LEAST A 5 STAGE COMPRESSOR MUST HAVE AT LEAST A 20 HP ELECTRIC MOTORMUST HAVE A PLC BASED CONTROLLER WITH AT LEAST A 6.75? SCREENMUST HAVE EMERGENCY STOP PUSH BUTTONMUST HAVE A NFPA 1901 2016 EDITION COMPLIANT 3 POSITION CONTAINMENT FILL STATION TO FIT SCBA OR SCUBA CYLINDERS UP TO 31?MUST HAVE CO/H2S MONITORING SYSTEM WITH AUDIBLE ALARMMUST BE ABLE TO FILL (3) SCBA OR SCUBA CYLINDERS SIMULTAINEOUSLY MUST BE 208V 3PHMUST BE CAPABLE OF PRODUCING 6000 PSIMUST HAVE A CHARGING RATE OF AT LEAST 25 SCFMMUST HAVE A SYSTEM OF AUDIBLE ALARMS WITH SAFETY SHUTDOWNSMUST HAVE COMPRESSOR LOW OIL PRESSURE AND HIGH TEMPERATURE SHUTDOWNSMUST HAVE AUTOMATIC CONDENSATE DRAIN SYSTEM WITH NON-CORROSIVE CONDENSATE RESERVOIR w/ INDICATOR TO SHUTDOWN WHEN FULLMUST HAVE SOUND ATTENUATING ENCLOSURE WITH TURN LATCH AND LIFT OFF TYPE HINGES

Update #1 ·

UNICUS IV:MUST HAVE A NEMA 4 RATED ELECTRICAL ENCLOSURE w/ UL LISTED CONTROL PANELMUST COME WITH PARTS AND REPAIR MANUALSMUST HAVE AIR INLET FILTER MAINTENANCE INDICATORMUST HAVE A VIRUS FREE INTAKE FILTERATION SYSTEMMUST HAVE (4) ASME CODE STAMPED AIR CYLINDERS INSTALLED IN AN INTEGRAL RACKMUST HAVE A P5 B-SECURUS PURIFICATION SYSTEMMUST BE AT LEAST A 5 STAGE COMPRESSOR MUST HAVE AT LEAST A 20 HP ELECTRIC MOTORMUST HAVE A PLC BASED CONTROLLER WITH AT LEAST A 6.75? SCREENMUST HAVE EMERGENCY STOP PUSH BUTTONMUST HAVE A NFPA 1901 2016 EDITION COMPLIANT 3 POSITION CONTAINMENT FILL STATION TO FIT SCBA OR SCUBA CYLINDERS UP TO 31?MUST HAVE CO/H2S MONITORING SYSTEM WITH AUDIBLE ALARMMUST BE ABLE TO FILL (3) SCBA OR SCUBA CYLINDERS SIMULTAINEOUSLY MUST BE 208V 3PHMUST BE CAPABLE OF PRODUCING 6000 PSIMUST HAVE A CHARGING RATE OF AT LEAST 25 SCFMMUST HAVE A SYSTEM OF AUDIBLE ALARMS WITH SAFETY SHUTDOWNSMUST HAVE COMPRESSOR LOW OIL PRESSURE AND HIGH TEMPERATURE SHUTDOWNSMUST HAVE AUTOMATIC CONDENSATE DRAIN SYSTEM WITH NON-CORROSIVE CONDENSATE RESERVOIR w/ INDICATOR TO SHUTDOWN WHEN FULLMUST HAVE SOUND ATTENUATING ENCLOSURE WITH TURN LATCH AND LIFT OFF TYPE HINGES

Similar open opportunities

Opportunity Agency Set-aside Responses due
Breathing apparatus, SE NAICS 339999 Construction and Equipment No set-aside
Breathing apparatus, SE NAICS 326299 Construction and Equipment Total Small Business
Facepiece, breathing EQ NAICS 315990 Construction and Equipment Service-Disabled Veteran-Owned Small Business
Fuel Dispenser Maintenance Fort Drum, New York 13602, United States · NAICS 811310 MICC Fort Drum Total Small Business
Ballistic Glass Panels Fort Leavenworth, KS 66027 · NAICS 332999 MICC Fort Drum Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity