C26-032 Altitude Test Chamber Blower Replacement

Closed Solicitation Posted

Solicitation number
FA812526Q0078
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Tinker AFB, Oklahoma 73145, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Air Force Materiel Command Air Force Sustainment Center seeks procurement of one Altitude Test Chamber Blower Replacement unit, with proposals due September 18, 2026 at 1:00 PM CST. The procurement is a small business set-aside. Amendment 2, effective September 12, posted Q&As and extended the due date from September 4 to September 18; contractors must acknowledge receipt of the amendment prior to the new deadline.

Place of performance is Tinker Air Force Base, Oklahoma City, Oklahoma. The replacement blower must be a Dearing Compressor and Pump Co. Pressure Blower System, Part Number DSP-2505-8CM-6-50 or equal, with identical form, fit, and function to the current Model 38406A (Serial Number 27335). Technical specifications include a centrifugal multistage design rated for inlet air pressure of 28 to 31 inches HgA, inlet air temperature from 0°F to 115°F, output capacity of 2,000 SCFM, and outlet pressure of 6 psig. The motor is 100 HP TEFC premium efficient, rated 460 VAC, 3-phase, 60 Hz at 3,600 rpm (or fixed-speed 3,550 rpm per Q&As), and the unit must mount on powder-coated I-Beam steel with all coupling components and rotational safety guards included. All components must be new. The contractor is responsible for manufacturing, functional testing, and shipping only; the government performs installation. Delivery is due within 19 weeks from award. The PSC code is 4310 (Compressors and Vacuum Pumps), NAICS 333912 (Air and Gas Compressor Manufacturing). Award goes to the responsible offeror offering the lowest evaluated price conforming to solicitation requirements, evaluated on technical merit and price reasonableness. Personnel must comply with TAFBI 31-101, AF 10-245, and TAFBP 31-101 badge requirements, with a $50 charge for lost or willfully damaged badges.

Notice text

3 versions

Update #3 · Latest ·

Amendment 2 posted to incorporate Q&As and extend closing date/time to 9/18/2026, by 1:00pm CST.

Amendment 1 posted to extend the closing date/time to Friday, 9/4/2026, by 1:00pm CST.

Please see solicitation and attachments.

Update #2 ·

Amendment 1 posted to extend the closing date/time to Friday, 9/4/2026, by 1:00pm CST.

Please see solicitation and attachments.

Update #1 ·

Please see solicitation and attachments

Files

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
C26-032 Altitude Test Chamber Blower Replacement Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Breathing Air Systems Services for Fire Emergency Services at EAFB and P42 Edwards, California 93524, United States · NAICS 811310 Air Force Test Center No set-aside
Blower, exhaust NAICS 333413 Land and Maritime No set-aside
Spacer, Compressor, R Tinker AFB, Oklahoma, United States · NAICS 336412 Aviation No set-aside
Case, compressor, air NAICS 336412 Aviation No set-aside
Blower, engine, eaps, in repair/modification of Naval Supply Systems Command No set-aside