C223--589-24-450, Upgrade Building 26 Chillers (A/E Design) (VA-24-00070212)
Closed Pre-Solicitation Posted
- Solicitation number
- 36C25524Q0339
- Agency
-
Veterans Integrated Service Network 15
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 541330 Engineering Services
- Place of performance
- Department of Veterans Affairs Kansas City VA Medical Center Kansas City MO 64128, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Department of Veterans Affairs (VA) is seeking Architectural and Engineering (A/E) services to produce construction documents, reports, and specifications for Project 589-24-450, Upgrade Building 26 Chillers at the Kansas City VA Medical Center. The project, valued between $5-10 million, involves replacing two Carrier chillers, upgrading the HVAC system, providing temporary cooling units, and installing a new emergency generator. The required A/E services include site investigation, architectural design, condition assessment, construction drawings and specifications, third-party cost estimates, construction period services, and an Infection Control Risk Assessment.
This procurement is a Service-Disabled Veteran-Owned Small Business (SDVOSB) total set-aside under NAICS code 541330 Engineering Services. Interested vendors are requested to provide a capabilities statement by May 3, 2024, at 2:00 pm Central Time. This Sources Sought Notice is for market research purposes only and does not constitute a solicitation.
Notice text
Project 589-24-450, Upgrade Building 26 Chillers
This is a Sources Sought request, looking for eligible vendors to respond to the following: NCO15 Contracting is asking for responsible vendors to provide a capabilities statement to meet the attached statement of work for design of Project 589-24-450, Upgrade Building 26 Chillers at the Kansas City VAMC. This is not an invitation for proposal and no solicitation will result from this announcement it is used for Market research only. This procurement is a SDVOSB total set aside and it will be solicited under NAICS Code: 541330 Architect and Engineering- Engineering Services.
General Statement: The U.S. Department of Veterans Affairs (VA) requires Architectural and Engineering (A/E) services to produce stand-alone Construction Documents, Reports, and Specifications for: Project 589-24-450, Upgrade Building 26 Chillers located at the Kansas City VA Medical Center (KCVA).
The construction magnitude of this project is between $5,000,000 and $10,000,000.
This project will replace two Carrier chillers located outside of Building 26, upgrade the existing HVAC system to support the new chillers, and provide a temporary unit to maintain services in the ICU's, Sterile Processing, and Operating Rooms while permanent units are being replaced. A new emergency generator will be installed to provide backup power for the increased electrical demand associated with the upgraded chillers. Temporary generator(s) to be provided as needed to complete the project.
Design Services: A/E services are required for preparation of Existing Condition Narrative/Studies, Phasing Design, Schematic Designs including options, Design Development, Construction Drawings (to include infection prevention and construction barriers through drawings and specifications), Specifications, Calculations, Commissioning, and As-Built Documents. Included in the scope of the A/E design services is to determine optimal phasing for the work and providing phasing documents. Professional disciplines will include but are not limited to Architectural, Interior Design, Structural, Sanitary, Plumbing, Heating, Ventilation, and Air Conditioning (HVAC), Electrical, Fire Detection and Protection, Steam, Telecommunications, Medical Gas, Automatic Door, Announcement System, Security, Third Party Commissioning, Environmental Safety and Health, Asbestos and Hazardous Materials Abatement, and Cost Estimating for this project. No VA provided information shall be considered accurate until confirmed by the A/E of record.
Summary of services that are required:
A. Site Investigation
B. Architectural Design
C. Condition Assessment
D. Construction drawings and specifications
E. Third party construction estimates
f. Construction Period Services
G. Conduct Infection Control Risk Assessment (ICRA) in conjunction with VA Safety/Infection Control staff
If you are interested in this project please provide a response by May 3, 2024, at 2:00 pm.
Files
| File | Type | Posted |
|---|---|---|
| 36C25524Q0339.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| C221--402-27-001 Repair Chiller 3 (AE) | Veterans Integrated Service Network 1 | Service-Disabled Veteran-Owned Small Business | |
| CON | Z1DA | replace or chillers | 580-23-105 | solicitation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| C222--657A5-24-108, FCA Replace Medium Voltage Feeder 3 and Transformers l MC FY27 NRM VISN Base DE | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--NCO 17 AE Short Selection Database FY24 - FY27 | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity